Skip to main content
620 XL vs 440 QD 8 of 19 identical Swap Change panels

Silfab SIL-620 XL vs Silfab SIL-440 QD

Silfab
SIL-620 XL
620 Wp 22.20 % N-type Bifacial
VS
Silfab SIL-440 QD
Silfab
SIL-440 QD
440 Wp 22.60 % N-type
The verdict

440 QD leads on the differences that matter

The largest is rated power: 180 W more power. 8 of 19 comparable parameters are identical.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs
01

What actually differs

11 of 19 parameters
Parameter 620 XL 440 QD Difference
Rated power 620 Wp 440 Wp 180 W more power
Weight 29.5 kg 21.0 kg 8.5 kg lighter
Module efficiency 22.20 % 22.60 % 0.40 pp more efficient
Open-circuit voltage 57.21 V 38.97 V 18.24 V apart
Module area 2.793 m² 1.950 m² 0.843 m² apart
Power density 222.0 Wp/m² 225.7 Wp/m² 3.7 Wp/m² higher
Voltage at max power 48.16 V 33.41 V 14.75 V apart
Cell count 156 108 48 cells apart
Bifacial Yes No Yes vs No
Short-circuit current 13.55 A 14.22 A 0.67 A apart
Dimensions 2465x1133x35 mm 1721x1133x35 mm 2465x1133x35 mm vs 1721x1133x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
620 XL
20,903 kWh
440 QD
14,834 kWh
Lifetime gap
6,069 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 620 XL 440 QD
Standard test conditions 25 °C 100.0% of rated power 620 W 440 W
Cool, bright day 40 °C 95.7% of rated power 593 W 421 W
Typical summer roof 55 °C 91.3% of rated power 566 W 402 W
Hot roof 70 °C 87.0% of rated power 539 W 383 W
03

Full specification

Parameter 620 XL 440 QD Difference
Power and efficiency
Rated power 620 Wp 440 Wp +180 W for 620 XL
Module efficiency 22.20 % 22.60 % +0.40 pp for 440 QD
Power density 222.0 Wp/m² 225.7 Wp/m² +3.7 Wp/m² for 440 QD
Open-circuit voltage 57.21 V 38.97 V 18.24 V apart
Voltage at max power 48.16 V 33.41 V 14.75 V apart
Short-circuit current 13.55 A 14.22 A 0.67 A apart
Current at max power 12.87 A 13.17 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2465x1133x35 mm 1721x1133x35 mm 2465x1133x35 mm vs 1721x1133x35 mm
Module area 2.793 m² 1.950 m² 0.843 m² apart
Weight 29.5 kg 21.0 kg -8.5 kg for 440 QD
Weight per kWp 47.6 kg/kWp 47.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 25 yrs 25 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.30 %/yr 0.30 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 156 108 48 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#5,817 vs #3,658
440 QD leads by 2,159 places
Power density
#5,849 vs #3,848
440 QD leads by 2,001 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#1,761 vs #1,829
620 XL leads by 68 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,404 vs #6,331
620 XL leads by 4,927 places
05

More useful comparisons

Open the full database
Same series, other bin
Silfab
Silfab SIL-620 XL vs Silfab SIL-640 XL
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-620 XL vs Silfab SIL-630 XL
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-440 QD vs Silfab SIL-430 QD
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-440 QD vs Silfab SIL-430-QD
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-440 QD vs Silfab SIL-420 QD
6 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-440 QD vs Silfab SIL-370 NT mono PERC
14 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Silfab SIL-620 XL or Silfab SIL-440 QD?
According to our database: Silfab SIL-440 QD has higher module efficiency (22.60% vs 22.20%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Silfab SIL-620 XL and Silfab SIL-440 QD?
Silfab SIL-620 XL has a module efficiency of 22.20%, while Silfab SIL-440 QD is 22.60%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Silfab SIL-620 XL use vs Silfab SIL-440 QD?
Silfab SIL-620 XL uses N-type cells; Silfab SIL-440 QD uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Silfab SIL-620 XL and Silfab SIL-440 QD?
Silfab SIL-620 XL has a 30 years power warranty; Silfab SIL-440 QD has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Silfab SIL-620 XL and Silfab SIL-440 QD bifacial panels?
Silfab SIL-620 XL is bifacial (captures light from both faces); Silfab SIL-440 QD is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 2 Silfab offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.