Skip to main content
450BNDG vs 460BNDG 16 of 19 identical Swap Change panels

Risen RSM96-11-450BNDG vs Risen RSM96-11-460BNDG

Risen RSM96-11-450BNDG
RSM96-11-450BNDG
450 Wp 22.50 % TOPCon Bifacial
VS
Risen RSM96-11-460BNDG
RSM96-11-460BNDG
460 Wp 23.00 % TOPCon Bifacial
The verdict

460BNDG leads on the differences that matter

The largest is module efficiency: 0.50 pp more efficient. 16 of 19 comparable parameters are identical.

See all 3 differences
How alike are they
16 of 19 comparable
parameters are identical
identical differs
01

What actually differs

3 of 19 parameters
Parameter 450BNDG 460BNDG Difference
Module efficiency 22.50 % 23.00 % 0.50 pp more efficient
Power density 225.2 Wp/m² 230.2 Wp/m² 5.0 Wp/m² higher
Rated power 450 Wp 460 Wp 10 W more power
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
450BNDG
15,098 kWh
460BNDG
15,434 kWh
Lifetime gap
336 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 450BNDG 460BNDG
Standard test conditions 25 °C 100.0% of rated power 450 W 460 W
Cool, bright day 40 °C 95.7% of rated power 430 W 440 W
Typical summer roof 55 °C 91.3% of rated power 411 W 420 W
Hot roof 70 °C 87.0% of rated power 391 W 400 W
03

Full specification

Parameter 450BNDG 460BNDG Difference
Power and efficiency
Rated power 450 Wp 460 Wp +10 W for 460BNDG
Module efficiency 22.50 % 23.00 % +0.50 pp for 460BNDG
Power density 225.2 Wp/m² 230.2 Wp/m² +5.0 Wp/m² for 460BNDG
Open-circuit voltage 35.40 V 35.79 V Effectively the same
Voltage at max power 29.90 V 30.28 V Effectively the same
Short-circuit current 16.14 A 16.30 A Effectively the same
Current at max power 15.06 A 15.22 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 21.5 kg 21.5 kg Same
Weight per kWp 47.8 kg/kWp 46.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 96 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#4,222 vs #1,919
460BNDG leads by 2,303 places
Power density
#4,225 vs #1,876
460BNDG leads by 2,349 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#1,891 vs #1,324
460BNDG leads by 567 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,379 vs #7,306
460BNDG leads by 1,073 places
05

More useful comparisons

Open the full database
Same series, other bin
Risen RSM96-11-450BNDG vs Risen RSM96-11-455BNDG
One difference: module efficiency
Same series, other bin
Risen RSM96-11-450BNDG vs Risen RSM96-11-445BNDG
One difference: module efficiency
Same series, other bin
Risen RSM96-11-450BNDG vs Risen RSM96-11-440BNDG
3 differences, the largest is module efficiency
Same manufacturer
Risen RSM96-11-450BNDG vs Risen RSM132-8-745BHDG
15 differences, the largest is module efficiency
Same manufacturer
Risen RSM96-11-450BNDG vs Risen RSM132-8-740BHDG
15 differences, the largest is module efficiency
Same manufacturer
Risen RSM96-11-450BNDG vs Risen RSM132-8-735BHDG
15 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Risen RSM96-11-450BNDG or Risen RSM96-11-460BNDG?
According to our database: Risen RSM96-11-460BNDG has higher module efficiency (23.00% vs 22.50%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Risen RSM96-11-450BNDG and Risen RSM96-11-460BNDG?
Risen RSM96-11-450BNDG has a module efficiency of 22.50%, while Risen RSM96-11-460BNDG is 23.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Risen RSM96-11-450BNDG use vs Risen RSM96-11-460BNDG?
Risen RSM96-11-450BNDG uses TOPCon cells; Risen RSM96-11-460BNDG uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Risen RSM96-11-450BNDG and Risen RSM96-11-460BNDG?
Risen RSM96-11-450BNDG has a 30 years power warranty; Risen RSM96-11-460BNDG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Risen RSM96-11-450BNDG and Risen RSM96-11-460BNDG bifacial panels?
Both Risen RSM96-11-450BNDG and Risen RSM96-11-460BNDG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 23 Risen offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.