Skip to main content
RCM-725-8DBNM vs GK-4-78HGBD-775M 4 of 19 identical Swap Change panels

Recom RCM-725-8DBNM vs Gokin GK-4-78HGBD-775M

Recom RCM-725-8DBNM
Recom
RCM-725-8DBNM
725 Wp 23.30 % TOPCon Bifacial
VS
Gokin GK-4-78HGBD-775M
Gokin
GK-4-78HGBD-775M
775 Wp 24.10 % Back Contact Bifacial
The verdict

GK-4-78HGBD-775M leads on the differences that matter

The largest is module efficiency: 0.80 pp more efficient. 4 of 19 comparable parameters are identical.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs
01

What actually differs

15 of 19 parameters
Parameter RCM-725-8DBNM GK-4-78HGBD-775M Difference
Module efficiency 23.30 % 24.10 % 0.80 pp more efficient
Rated power 725 Wp 775 Wp 50 W more power
Temperature coefficient -0.290 %/°C -0.260 %/°C 0.030 %/°C better in heat
Product warranty 30 yrs 15 yrs 15 yrs longer
Power density 233.4 Wp/m² 241.3 Wp/m² 7.9 Wp/m² higher
Open-circuit voltage 49.41 V 58.82 V 9.41 V apart
Module area 3.106 m² 3.212 m² 0.106 m² apart
Short-circuit current 18.64 A 16.71 A 1.93 A apart
Cell technology TOPCon Back Contact TOPCon vs Back Contact
Annual degradation 0.40 %/yr 0.35 %/yr 0.05 %/yr slower
Voltage at max power 41.27 V 48.87 V 7.60 V apart
Cell count 132 156 24 cells apart
Current at max power 17.57 A 15.86 A 1.71 A apart
Weight per kWp 52.1 kg/kWp 49.9 kg/kWp 2.2 kg/kWp lighter
Dimensions 2384x1303x33 mm 2465x1303x33 mm 2384x1303x33 mm vs 2465x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
RCM-725-8DBNM
24,325 kWh
GK-4-78HGBD-775M
26,205 kWh
Lifetime gap
1,880 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario RCM-725-8DBNM GK-4-78HGBD-775M
Standard test conditions 25 °C 100.0% of rated power 725 W 775 W
Cool, bright day 40 °C 95.7% of rated power 693 W 745 W
Typical summer roof 55 °C 91.3% of rated power 662 W 715 W
Hot roof 70 °C 87.0% of rated power 630 W 684 W
03

Full specification

Parameter RCM-725-8DBNM GK-4-78HGBD-775M Difference
Power and efficiency
Rated power 725 Wp 775 Wp +50 W for GK-4-78HGBD-775M
Module efficiency 23.30 % 24.10 % +0.80 pp for GK-4-78HGBD-775M
Power density 233.4 Wp/m² 241.3 Wp/m² +7.9 Wp/m² for GK-4-78HGBD-775M
Open-circuit voltage 49.41 V 58.82 V 9.41 V apart
Voltage at max power 41.27 V 48.87 V 7.60 V apart
Short-circuit current 18.64 A 16.71 A 1.93 A apart
Current at max power 17.57 A 15.86 A 1.71 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.260 %/°C +0.030 %/°C for GK-4-78HGBD-775M
Mechanical
Dimensions 2384x1303x33 mm 2465x1303x33 mm 2384x1303x33 mm vs 2465x1303x33 mm
Module area 3.106 m² 3.212 m² 0.106 m² apart
Weight 37.8 kg 38.7 kg Effectively the same
Weight per kWp 52.1 kg/kWp 49.9 kg/kWp -2.2 kg/kWp for GK-4-78HGBD-775M
Warranty and degradation
Product warranty 30 yrs 15 yrs +15 yrs for RCM-725-8DBNM
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.35 %/yr -0.05 %/yr for GK-4-78HGBD-775M
Technology
Cell technology TOPCon Back Contact TOPCon vs Back Contact
Cell type Monocrystalline Monocrystalline Same
Cell count 132 156 24 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#1,017 vs #219
GK-4-78HGBD-775M leads by 798 places
Power density
#936 vs #227
GK-4-78HGBD-775M leads by 709 places
Heat behaviour
#2,165 vs #511
GK-4-78HGBD-775M leads by 1,654 places
Weight
#5,609 vs #3,297
GK-4-78HGBD-775M leads by 2,312 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#14 vs #29
RCM-725-8DBNM leads by 15 places
05

More useful comparisons

Open the full database
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-730-8DBNM
One difference: module efficiency
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-720-8DBNM
The same specification on paper
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-715-8DBNM
3 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-715-8NM
8 differences, the largest is weight
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-710-8DBNM
3 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-725-8DBNM vs Recom RCM-710-8NM
8 differences, the largest is weight
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Recom RCM-725-8DBNM or Gokin GK-4-78HGBD-775M?
According to our database: Gokin GK-4-78HGBD-775M has higher module efficiency (24.10% vs 23.30%); Gokin GK-4-78HGBD-775M tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Recom RCM-725-8DBNM and Gokin GK-4-78HGBD-775M?
Recom RCM-725-8DBNM has a module efficiency of 23.30%, while Gokin GK-4-78HGBD-775M is 24.10%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Recom RCM-725-8DBNM use vs Gokin GK-4-78HGBD-775M?
Recom RCM-725-8DBNM uses TOPCon cells; Gokin GK-4-78HGBD-775M uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Recom RCM-725-8DBNM and Gokin GK-4-78HGBD-775M?
Recom RCM-725-8DBNM has a 30 years power warranty; Gokin GK-4-78HGBD-775M has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Recom RCM-725-8DBNM and Gokin GK-4-78HGBD-775M bifacial panels?
Both Recom RCM-725-8DBNM and Gokin GK-4-78HGBD-775M are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Compare Recom and Gokin as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 3 Recom offers · See 7 Gokin offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.