Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-725-8DBNM
VS
The verdict
725-8DBNM leads on the differences that matter
The largest is module efficiency: 1.28 pp more efficient. 6 of 19 comparable parameters are identical.
See all 13 differencesHow alike are they
6
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
13 of 19 parameters
What actually differs
Parameter
440-RDBNAA (Lynx series)
725-8DBNM
Difference
Module efficiency
22.02 %
23.30 %
1.28 pp more efficient
Rated power
440 Wp
725 Wp
285 W more power
Power density
220.2 Wp/m²
233.4 Wp/m²
13.2 Wp/m² higher
Weight
25.0 kg
37.8 kg
12.8 kg lighter
Open-circuit voltage
35.10 V
49.41 V
14.31 V apart
Short-circuit current
15.89 A
18.64 A
2.75 A apart
Module area
1.998 m²
3.106 m²
1.108 m² apart
Weight per kWp
56.8 kg/kWp
52.1 kg/kWp
4.7 kg/kWp lighter
Temperature coefficient
-0.280 %/°C
-0.290 %/°C
0.010 %/°C better in heat
Voltage at max power
29.40 V
41.27 V
11.87 V apart
Current at max power
14.97 A
17.57 A
2.60 A apart
Cell count
192
132
60 cells apart
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
440-RDBNAA (Lynx series)
14,763 kWh
725-8DBNM
24,325 kWh
Lifetime gap
9,562 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
440-RDBNAA (Lynx series)
725-8DBNM
Standard test conditions
25 °C
100.0% of rated power
440 W
725 W
Cool, bright day
40 °C
95.7% of rated power
422 W
693 W
Typical summer roof
55 °C
91.3% of rated power
403 W
662 W
Hot roof
70 °C
87.0% of rated power
385 W
630 W
03
Full specification
Parameter
440-RDBNAA (Lynx series)
725-8DBNM
Difference
Power and efficiency
Rated power
440 Wp
725 Wp
+285 W for 725-8DBNM
Module efficiency
22.02 %
23.30 %
+1.28 pp for 725-8DBNM
Power density
220.2 Wp/m²
233.4 Wp/m²
+13.2 Wp/m² for 725-8DBNM
Open-circuit voltage
35.10 V
49.41 V
14.31 V apart
Voltage at max power
29.40 V
41.27 V
11.87 V apart
Short-circuit current
15.89 A
18.64 A
2.75 A apart
Current at max power
14.97 A
17.57 A
2.60 A apart
Temperature
Temperature coefficient
-0.280 %/°C
-0.290 %/°C
+0.010 %/°C for 440-RDBNAA (Lynx series)
Mechanical
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
Module area
1.998 m²
3.106 m²
1.108 m² apart
Weight
25.0 kg
37.8 kg
-12.8 kg for 440-RDBNAA (Lynx series)
Weight per kWp
56.8 kg/kWp
52.1 kg/kWp
-4.7 kg/kWp for 725-8DBNM
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
192
132
60 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#6,329
vs
#1,017
725-8DBNM leads by 5,312 places
Power density
#6,328
vs
#936
725-8DBNM leads by 5,392 places
Heat behaviour
#1,309
vs
#2,165
440-RDBNAA (Lynx series) leads by 856 places
Weight
#10,878
vs
#5,609
725-8DBNM leads by 5,269 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#6,090
vs
#14
725-8DBNM leads by 6,076 places
05
Open the full database
More useful comparisons
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-730-8DBNM
13 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-720-8DBNM
13 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-715-8DBNM
13 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-715-8NM
13 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-710-8DBNM
13 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-440-RDBNAA (Lynx series) vs Recom RCM-710-8NM
13 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Recom RCM-440-RDBNAA (Lynx series) or Recom RCM-725-8DBNM?
According to our database: Recom RCM-725-8DBNM has higher module efficiency (23.30% vs 22.02%); Recom RCM-440-RDBNAA (Lynx series) tolerates heat better (temp coeff -0.280%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Recom RCM-440-RDBNAA (Lynx series) and Recom RCM-725-8DBNM?
Recom RCM-440-RDBNAA (Lynx series) has a module efficiency of 22.02%, while Recom RCM-725-8DBNM is 23.30%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Recom RCM-440-RDBNAA (Lynx series) use vs Recom RCM-725-8DBNM?
Recom RCM-440-RDBNAA (Lynx series) uses TOPCon cells; Recom RCM-725-8DBNM uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Recom RCM-440-RDBNAA (Lynx series) and Recom RCM-725-8DBNM?
Recom RCM-440-RDBNAA (Lynx series) has a 30 years power warranty; Recom RCM-725-8DBNM has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Recom RCM-440-RDBNAA (Lynx series) and Recom RCM-725-8DBNM bifacial panels?
Both Recom RCM-440-RDBNAA (Lynx series) and Recom RCM-725-8DBNM are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 3 Recom offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.