Skip to main content
PVN700-M12TCBB (TRION) vs PVN465-M12TCBB 6 of 19 identical Swap Change panels

PVolution PVN700-M12TCBB (TRION) vs PVolution PVN465-M12TCBB

PVolution PVN700-M12TCBB (TRION)
PVolution
PVN700-M12TCBB (TRION)
700 Wp 22.53 % HJT Bifacial
VS
PVolution PVN465-M12TCBB
PVolution
PVN465-M12TCBB
465 Wp 23.27 % HJT Bifacial
The verdict

PVN465-M12TCBB leads on the differences that matter

The largest is module efficiency: 0.74 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter PVN700-M12TCBB (TRION) PVN465-M12TCBB Difference
Module efficiency 22.53 % 23.27 % 0.74 pp more efficient
Rated power 700 Wp 465 Wp 235 W more power
Temperature coefficient -0.260 %/°C -0.290 %/°C 0.030 %/°C better in heat
Weight 38.7 kg 23.0 kg 15.7 kg lighter
Power density 225.3 Wp/m² 232.7 Wp/m² 7.4 Wp/m² higher
Weight per kWp 55.3 kg/kWp 49.5 kg/kWp 5.8 kg/kWp lighter
Open-circuit voltage 50.13 V 36.14 V 13.99 V apart
Module area 3.106 m² 1.998 m² 1.108 m² apart
Short-circuit current 17.43 A 16.32 A 1.11 A apart
Voltage at max power 42.10 V 30.03 V 12.07 V apart
Cell count 132 96 36 cells apart
Current at max power 16.63 A 15.49 A 1.14 A apart
Dimensions 2384x1303x35 mm 1762x1134x30 mm 2384x1303x35 mm vs 1762x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
PVN700-M12TCBB (TRION)
23,559 kWh
PVN465-M12TCBB
15,602 kWh
Lifetime gap
7,957 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario PVN700-M12TCBB (TRION) PVN465-M12TCBB
Standard test conditions 25 °C 100.0% of rated power 700 W 465 W
Cool, bright day 40 °C 95.7% of rated power 673 W 445 W
Typical summer roof 55 °C 91.3% of rated power 645 W 425 W
Hot roof 70 °C 87.0% of rated power 618 W 404 W
03

Full specification

Parameter PVN700-M12TCBB (TRION) PVN465-M12TCBB Difference
Power and efficiency
Rated power 700 Wp 465 Wp +235 W for PVN700-M12TCBB (TRION)
Module efficiency 22.53 % 23.27 % +0.74 pp for PVN465-M12TCBB
Power density 225.3 Wp/m² 232.7 Wp/m² +7.4 Wp/m² for PVN465-M12TCBB
Open-circuit voltage 50.13 V 36.14 V 13.99 V apart
Voltage at max power 42.10 V 30.03 V 12.07 V apart
Short-circuit current 17.43 A 16.32 A 1.11 A apart
Current at max power 16.63 A 15.49 A 1.14 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.290 %/°C +0.030 %/°C for PVN700-M12TCBB (TRION)
Mechanical
Dimensions 2384x1303x35 mm 1762x1134x30 mm 2384x1303x35 mm vs 1762x1134x30 mm
Module area 3.106 m² 1.998 m² 1.108 m² apart
Weight 38.7 kg 23.0 kg -15.7 kg for PVN465-M12TCBB
Weight per kWp 55.3 kg/kWp 49.5 kg/kWp -5.8 kg/kWp for PVN465-M12TCBB
Warranty and degradation
Product warranty 30 yrs 30 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.38 %/yr 0.40 %/yr Effectively the same
Technology
Cell technology HJT HJT Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 96 36 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#3,982 vs #1,202
PVN465-M12TCBB leads by 2,780 places
Power density
#3,989 vs #1,115
PVN465-M12TCBB leads by 2,874 places
Heat behaviour
#511 vs #2,165
PVN700-M12TCBB (TRION) leads by 1,654 places
Weight
#9,733 vs #2,991
PVN465-M12TCBB leads by 6,742 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#116 vs #3,739
PVN700-M12TCBB (TRION) leads by 3,623 places
05

More useful comparisons

Open the full database
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN720-M12TCBB
3 differences, the largest is module efficiency
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN715-M12TCBB
3 differences, the largest is module efficiency
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN710-M12TCBB (TRION)
3 differences, the largest is module efficiency
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN705-M12TCBB (TRION)
The same specification on paper
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN470-M12TCBB
13 differences, the largest is module efficiency
Same series, other bin
PVolution
PVolution PVN700-M12TCBB (TRION) vs PVolution PVN460-M12TCBB
13 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: PVolution PVN700-M12TCBB (TRION) or PVolution PVN465-M12TCBB?
According to our database: PVolution PVN465-M12TCBB has higher module efficiency (23.27% vs 22.53%); PVolution PVN700-M12TCBB (TRION) tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of PVolution PVN700-M12TCBB (TRION) and PVolution PVN465-M12TCBB?
PVolution PVN700-M12TCBB (TRION) has a module efficiency of 22.53%, while PVolution PVN465-M12TCBB is 23.27%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does PVolution PVN700-M12TCBB (TRION) use vs PVolution PVN465-M12TCBB?
PVolution PVN700-M12TCBB (TRION) uses HJT cells; PVolution PVN465-M12TCBB uses HJT. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on PVolution PVN700-M12TCBB (TRION) and PVolution PVN465-M12TCBB?
PVolution PVN700-M12TCBB (TRION) has a 30 years power warranty; PVolution PVN465-M12TCBB has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are PVolution PVN700-M12TCBB (TRION) and PVolution PVN465-M12TCBB bifacial panels?
Both PVolution PVN700-M12TCBB (TRION) and PVolution PVN465-M12TCBB are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.