Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P6-525-UPP
VS
The verdict
P7-530-COM-S leads on the differences that matter
The largest is module efficiency: 1.50 pp more efficient. 3 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 15 differencesHow alike are they
3
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 18 parameters
What actually differs
Parameter
P7-530-COM-S
P6-525-UPP
Difference
Module efficiency
21.70 %
20.20 %
1.50 pp more efficient
Temperature coefficient
-0.290 %/°C
-0.340 %/°C
0.050 %/°C better in heat
Power density
216.8 Wp/m²
201.7 Wp/m²
15.1 Wp/m² higher
Performance warranty
30 yrs
25 yrs
5 yrs longer
Product warranty
30 yrs
25 yrs
5 yrs longer
Module area
2.445 m²
2.603 m²
0.158 m² apart
Open-circuit voltage
49.94 V
46.10 V
3.84 V apart
Weight per kWp
57.2 kg/kWp
61.7 kg/kWp
4.5 kg/kWp lighter
Weight
30.3 kg
32.4 kg
2.1 kg lighter
Cell technology
TOPCon
PERC
TOPCon vs PERC
Short-circuit current
13.36 A
14.44 A
1.08 A apart
Annual degradation
0.40 %/yr
0.45 %/yr
0.05 %/yr slower
Voltage at max power
42.17 V
38.50 V
3.67 V apart
Current at max power
12.57 A
13.62 A
1.05 A apart
Dimensions
2156x1134x35 mm
2384x1092x35 mm
2156x1134x35 mm vs 2384x1092x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
P7-530-COM-S
17,783 kWh
P6-525-UPP
17,289 kWh
Lifetime gap
494 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
P7-530-COM-S
P6-525-UPP
Standard test conditions
25 °C
100.0% of rated power
530 W
525 W
Cool, bright day
40 °C
94.9% of rated power
507 W
498 W
Typical summer roof
55 °C
89.8% of rated power
484 W
471 W
Hot roof
70 °C
84.7% of rated power
461 W
445 W
03
Full specification
Parameter
P7-530-COM-S
P6-525-UPP
Difference
Power and efficiency
Rated power
530 Wp
525 Wp
Effectively the same
Module efficiency
21.70 %
20.20 %
+1.50 pp for P7-530-COM-S
Power density
216.8 Wp/m²
201.7 Wp/m²
+15.1 Wp/m² for P7-530-COM-S
Open-circuit voltage
49.94 V
46.10 V
3.84 V apart
Voltage at max power
42.17 V
38.50 V
3.67 V apart
Short-circuit current
13.36 A
14.44 A
1.08 A apart
Current at max power
12.57 A
13.62 A
1.05 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.340 %/°C
+0.050 %/°C for P7-530-COM-S
Mechanical
Dimensions
2156x1134x35 mm
2384x1092x35 mm
2156x1134x35 mm vs 2384x1092x35 mm
Module area
2.445 m²
2.603 m²
0.158 m² apart
Weight
30.3 kg
32.4 kg
-2.1 kg for P7-530-COM-S
Weight per kWp
57.2 kg/kWp
61.7 kg/kWp
-4.5 kg/kWp for P7-530-COM-S
Warranty and degradation
Product warranty
30 yrs
25 yrs
+5 yrs for P7-530-COM-S
Performance warranty
30 yrs
25 yrs
+5 yrs for P7-530-COM-S
Annual degradation
0.40 %/yr
0.45 %/yr
-0.05 %/yr for P7-530-COM-S
Technology
Cell technology
TOPCon
PERC
TOPCon vs PERC
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
-
-
Neither datasheet publishes this
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#7,628
vs
#12,232
P7-530-COM-S leads by 4,604 places
Power density
#7,738
vs
#12,296
P7-530-COM-S leads by 4,558 places
Heat behaviour
#2,288
vs
#9,020
P7-530-COM-S leads by 6,732 places
Weight
#11,370
vs
#12,978
P7-530-COM-S leads by 1,608 places
Warranty
#31
vs
#10,073
P7-530-COM-S leads by 10,042 places
Overall
#3,569
vs
#7,695
P7-530-COM-S leads by 4,126 places
05
Open the full database
More useful comparisons
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P7-555-COM-S
5 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P7-550-COM-S
4 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P7-545-COM-S
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P7-540-COM-S
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P7-535-COM-S
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-P7-530-COM-S vs Maxeon SPR-P6-520-UPP
16 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Maxeon SPR-P7-530-COM-S or Maxeon SPR-P6-525-UPP?
According to our database: Maxeon SPR-P7-530-COM-S has higher module efficiency (21.70% vs 20.20%); Maxeon SPR-P7-530-COM-S tolerates heat better (temp coeff -0.290%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-P7-530-COM-S and Maxeon SPR-P6-525-UPP?
Maxeon SPR-P7-530-COM-S has a module efficiency of 21.70%, while Maxeon SPR-P6-525-UPP is 20.20%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-P7-530-COM-S use vs Maxeon SPR-P6-525-UPP?
Maxeon SPR-P7-530-COM-S uses TOPCon cells; Maxeon SPR-P6-525-UPP uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-P7-530-COM-S and Maxeon SPR-P6-525-UPP?
Maxeon SPR-P7-530-COM-S has a 30 years power warranty; Maxeon SPR-P6-525-UPP has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Maxeon SPR-P7-530-COM-S and Maxeon SPR-P6-525-UPP bifacial panels?
Both Maxeon SPR-P7-530-COM-S and Maxeon SPR-P6-525-UPP are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 19 Maxeon offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.
