Maxeon SPR-BE66-GD610 vs AE Solar CME-132BDS-730
VS
The verdict
SPR-BE66-GD610 leads on the differences that matter
The largest is module efficiency: 1.07 pp more efficient. 5 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 13 differencesHow alike are they
5
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 18 parameters
What actually differs
Parameter
SPR-BE66-GD610
CME-132BDS-730
Difference
Module efficiency
24.60 %
23.53 %
1.07 pp more efficient
Rated power
610 Wp
730 Wp
120 W more power
Performance warranty
40 yrs
30 yrs
10 yrs longer
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
0.030 %/°C better in heat
Power density
245.6 Wp/m²
235.3 Wp/m²
10.3 Wp/m² higher
Annual degradation
0.25 %/yr
0.40 %/yr
0.15 %/yr slower
Weight
30.1 kg
37.0 kg
6.9 kg lighter
Product warranty
40 yrs
30 yrs
10 yrs longer
Short-circuit current
15.46 A
18.49 A
3.03 A apart
Module area
2.483 m²
3.103 m²
0.619 m² apart
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Current at max power
14.68 A
17.51 A
2.83 A apart
Dimensions
2190x1134x30 mm
2383x1302x30 mm
2190x1134x30 mm vs 2383x1302x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
SPR-BE66-GD610
20,944 kWh
CME-132BDS-730
24,493 kWh
Lifetime gap
3,549 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
SPR-BE66-GD610
CME-132BDS-730
Standard test conditions
25 °C
100.0% of rated power
610 W
730 W
Cool, bright day
40 °C
95.7% of rated power
586 W
698 W
Typical summer roof
55 °C
91.3% of rated power
562 W
666 W
Hot roof
70 °C
87.0% of rated power
539 W
635 W
03
Full specification
Parameter
SPR-BE66-GD610
CME-132BDS-730
Difference
Power and efficiency
Rated power
610 Wp
730 Wp
+120 W for CME-132BDS-730
Module efficiency
24.60 %
23.53 %
+1.07 pp for SPR-BE66-GD610
Power density
245.6 Wp/m²
235.3 Wp/m²
+10.3 Wp/m² for SPR-BE66-GD610
Open-circuit voltage
49.83 V
49.50 V
Effectively the same
Voltage at max power
41.56 V
41.70 V
Effectively the same
Short-circuit current
15.46 A
18.49 A
3.03 A apart
Current at max power
14.68 A
17.51 A
2.83 A apart
Temperature
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
+0.030 %/°C for SPR-BE66-GD610
Mechanical
Dimensions
2190x1134x30 mm
2383x1302x30 mm
2190x1134x30 mm vs 2383x1302x30 mm
Module area
2.483 m²
3.103 m²
0.619 m² apart
Weight
30.1 kg
37.0 kg
-6.9 kg for SPR-BE66-GD610
Weight per kWp
49.3 kg/kWp
50.7 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
40 yrs
30 yrs
+10 yrs for SPR-BE66-GD610
Performance warranty
40 yrs
30 yrs
+10 yrs for SPR-BE66-GD610
Annual degradation
0.25 %/yr
0.40 %/yr
-0.15 %/yr for SPR-BE66-GD610
Technology
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
-
132
Not published by Maxeon
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#73
vs
#766
SPR-BE66-GD610 leads by 693 places
Power density
#99
vs
#764
SPR-BE66-GD610 leads by 665 places
Heat behaviour
#521
vs
#2,288
SPR-BE66-GD610 leads by 1,767 places
Weight
#2,900
vs
#4,181
SPR-BE66-GD610 leads by 1,281 places
Warranty
#1
vs
#31
SPR-BE66-GD610 leads by 30 places
Overall
#3
vs
#11
SPR-BE66-GD610 leads by 8 places
05
Open the full database
More useful comparisons
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE66-GD615
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE66-GD605
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE66-GD600
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE66-GD595
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE54-HD505
8 differences, the largest is rated power
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD610 vs Maxeon SPR-BE54-HD500
8 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Maxeon SPR-BE66-GD610 or AE Solar CME-132BDS-730?
According to our database: Maxeon SPR-BE66-GD610 has higher module efficiency (24.60% vs 23.53%); Maxeon SPR-BE66-GD610 tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-BE66-GD610 and AE Solar CME-132BDS-730?
Maxeon SPR-BE66-GD610 has a module efficiency of 24.60%, while AE Solar CME-132BDS-730 is 23.53%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-BE66-GD610 use vs AE Solar CME-132BDS-730?
Maxeon SPR-BE66-GD610 uses Back Contact cells; AE Solar CME-132BDS-730 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-BE66-GD610 and AE Solar CME-132BDS-730?
Maxeon SPR-BE66-GD610 has a 40 years power warranty; AE Solar CME-132BDS-730 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Maxeon SPR-BE66-GD610 and AE Solar CME-132BDS-730 bifacial panels?
Both Maxeon SPR-BE66-GD610 and AE Solar CME-132BDS-730 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 19 Maxeon offers · See 3 AE Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.