Skip to main content
SPR-BE66-GD600 vs AE CME-132 720 3 of 17 identical Swap Change panels

Maxeon SPR-BE66-GD600 vs AE Solar AE CME-132 720

Maxeon
SPR-BE66-GD600
600 Wp 24.20 % Back Contact Bifacial
VS
AE Solar AE CME-132 720
AE CME-132 720
720 Wp 23.21 % TOPCon Incomplete
The verdict

SPR-BE66-GD600 leads on the differences that matter

The largest is module efficiency: 0.99 pp more efficient. 3 of 17 comparable parameters are identical, with 2 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
3 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 17 parameters
Parameter SPR-BE66-GD600 AE CME-132 720 Difference
Module efficiency 24.20 % 23.21 % 0.99 pp more efficient
Rated power 600 Wp 720 Wp 120 W more power
Performance warranty 40 yrs 30 yrs 10 yrs longer
Temperature coefficient -0.260 %/°C -0.290 %/°C 0.030 %/°C better in heat
Power density 241.6 Wp/m² 232.1 Wp/m² 9.5 Wp/m² higher
Product warranty 40 yrs 30 yrs 10 yrs longer
Weight per kWp 50.2 kg/kWp 43.8 kg/kWp 6.4 kg/kWp lighter
Short-circuit current 15.30 A 18.43 A 3.13 A apart
Module area 2.483 m² 3.103 m² 0.619 m² apart
Cell technology Back Contact TOPCon Back Contact vs TOPCon
Weight 30.1 kg 31.5 kg 1.4 kg lighter
Current at max power 14.52 A 17.43 A 2.91 A apart
Bifacial Yes No Yes vs No
Dimensions 2190x1134x30 mm 2383x1302x30 mm 2190x1134x30 mm vs 2383x1302x30 mm
02

What it means on a roof

Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
SPR-BE66-GD600
20,131 kWh
AE CME-132 720
24,157 kWh
Lifetime gap
4,026 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario SPR-BE66-GD600 AE CME-132 720
Standard test conditions 25 °C 100.0% of rated power 600 W 720 W
Cool, bright day 40 °C 95.7% of rated power 577 W 689 W
Typical summer roof 55 °C 91.3% of rated power 553 W 657 W
Hot roof 70 °C 87.0% of rated power 530 W 626 W
03

Full specification

Parameter SPR-BE66-GD600 AE CME-132 720 Difference
Power and efficiency
Rated power 600 Wp 720 Wp +120 W for AE CME-132 720
Module efficiency 24.20 % 23.21 % +0.99 pp for SPR-BE66-GD600
Power density 241.6 Wp/m² 232.1 Wp/m² +9.5 Wp/m² for SPR-BE66-GD600
Open-circuit voltage 49.59 V 49.10 V Effectively the same
Voltage at max power 41.33 V 41.30 V Effectively the same
Short-circuit current 15.30 A 18.43 A 3.13 A apart
Current at max power 14.52 A 17.43 A 2.91 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.290 %/°C +0.030 %/°C for SPR-BE66-GD600
Mechanical
Dimensions 2190x1134x30 mm 2383x1302x30 mm 2190x1134x30 mm vs 2383x1302x30 mm
Module area 2.483 m² 3.103 m² 0.619 m² apart
Weight 30.1 kg 31.5 kg -1.4 kg for SPR-BE66-GD600
Weight per kWp 50.2 kg/kWp 43.8 kg/kWp -6.4 kg/kWp for AE CME-132 720
Warranty and degradation
Product warranty 40 yrs 30 yrs +10 yrs for SPR-BE66-GD600
Performance warranty 40 yrs 30 yrs +10 yrs for SPR-BE66-GD600
Annual degradation 0.25 %/yr - Not published by AE Solar
Technology
Cell technology Back Contact TOPCon Back Contact vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count - 132 Not published by Maxeon
Bifacial Yes No Yes vs No
04

Against the whole database

14,354 panels
Efficiency
#242 vs #1,412
SPR-BE66-GD600 leads by 1,170 places
Power density
#273 vs #1,452
SPR-BE66-GD600 leads by 1,179 places
Heat behaviour
#521 vs #2,288
SPR-BE66-GD600 leads by 1,767 places
Weight
#3,712 vs #338
AE CME-132 720 leads by 3,374 places
Warranty
#1 vs #31
SPR-BE66-GD600 leads by 30 places
Overall
#8 vs #24
SPR-BE66-GD600 leads by 16 places
05

More useful comparisons

Open the full database
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE66-GD615
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE66-GD610
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE66-GD605
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE66-GD595
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE54-HD505
9 differences, the largest is rated power
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD600 vs Maxeon SPR-BE54-HD500
9 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Maxeon SPR-BE66-GD600 or AE Solar AE CME-132 720?
According to our database: Maxeon SPR-BE66-GD600 has higher module efficiency (24.20% vs 23.21%); Maxeon SPR-BE66-GD600 tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-BE66-GD600 and AE Solar AE CME-132 720?
Maxeon SPR-BE66-GD600 has a module efficiency of 24.20%, while AE Solar AE CME-132 720 is 23.21%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-BE66-GD600 use vs AE Solar AE CME-132 720?
Maxeon SPR-BE66-GD600 uses Back Contact cells; AE Solar AE CME-132 720 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-BE66-GD600 and AE Solar AE CME-132 720?
Maxeon SPR-BE66-GD600 has a 40 years power warranty; AE Solar AE CME-132 720 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Maxeon SPR-BE66-GD600 and AE Solar AE CME-132 720 bifacial panels?
Maxeon SPR-BE66-GD600 is bifacial (captures light from both faces); AE Solar AE CME-132 720 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare Maxeon and AE Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 18 Maxeon offers · See 3 AE Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.