Maxeon SPR-BE66-GD595 vs AIKO AIKO-A800-GRH78Dw
VS
The verdict
12 differences, and they point both ways
The largest is module efficiency: 0.90 pp more efficient. 5 of 17 comparable parameters are identical, with 2 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
5
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 17 parameters
What actually differs
Parameter
SPR-BE66-GD595
AIKO-A800-GRH78Dw
Difference
Module efficiency
24.00 %
24.90 %
0.90 pp more efficient
Rated power
595 Wp
800 Wp
205 W more power
Performance warranty
40 yrs
30 yrs
10 yrs longer
Power density
239.6 Wp/m²
249.1 Wp/m²
9.5 Wp/m² higher
Weight
30.1 kg
39.8 kg
9.7 kg lighter
Product warranty
40 yrs
15 yrs
25 yrs longer
Open-circuit voltage
49.47 V
59.32 V
9.85 V apart
Module area
2.483 m²
3.212 m²
0.728 m² apart
Short-circuit current
15.22 A
17.06 A
1.84 A apart
Voltage at max power
41.21 V
49.36 V
8.15 V apart
Current at max power
14.44 A
16.21 A
1.77 A apart
Dimensions
2190x1134x30 mm
2465x1303x33 mm
2190x1134x30 mm vs 2465x1303x33 mm
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.260 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
SPR-BE66-GD595
19,963 kWh
AIKO-A800-GRH78Dw
26,842 kWh
Lifetime gap
6,879 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
SPR-BE66-GD595
AIKO-A800-GRH78Dw
Standard test conditions
25 °C
100.0% of rated power
595 W
800 W
Cool, bright day
40 °C
96.1% of rated power
572 W
769 W
Typical summer roof
55 °C
92.2% of rated power
549 W
738 W
Hot roof
70 °C
88.3% of rated power
525 W
706 W
03
Full specification
Parameter
SPR-BE66-GD595
AIKO-A800-GRH78Dw
Difference
Power and efficiency
Rated power
595 Wp
800 Wp
+205 W for AIKO-A800-GRH78Dw
Module efficiency
24.00 %
24.90 %
+0.90 pp for AIKO-A800-GRH78Dw
Power density
239.6 Wp/m²
249.1 Wp/m²
+9.5 Wp/m² for AIKO-A800-GRH78Dw
Open-circuit voltage
49.47 V
59.32 V
9.85 V apart
Voltage at max power
41.21 V
49.36 V
8.15 V apart
Short-circuit current
15.22 A
17.06 A
1.84 A apart
Current at max power
14.44 A
16.21 A
1.77 A apart
Temperature
Temperature coefficient
-0.260 %/°C
-0.260 %/°C
Same
Mechanical
Dimensions
2190x1134x30 mm
2465x1303x33 mm
2190x1134x30 mm vs 2465x1303x33 mm
Module area
2.483 m²
3.212 m²
0.728 m² apart
Weight
30.1 kg
39.8 kg
-9.7 kg for SPR-BE66-GD595
Weight per kWp
50.6 kg/kWp
49.7 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
40 yrs
15 yrs
+25 yrs for SPR-BE66-GD595
Performance warranty
40 yrs
30 yrs
+10 yrs for SPR-BE66-GD595
Annual degradation
0.25 %/yr
-
Not published by AIKO
Technology
Cell technology
Back Contact
Back Contact
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
-
156
Not published by Maxeon
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#373
vs
#15
AIKO-A800-GRH78Dw leads by 358 places
Power density
#427
vs
#15
AIKO-A800-GRH78Dw leads by 412 places
Heat behaviour
#521
vs
#521
Tied - the same position in the database
Weight
#4,081
vs
#3,256
AIKO-A800-GRH78Dw leads by 825 places
Warranty
#1
vs
#31
SPR-BE66-GD595 leads by 30 places
Overall
#14
vs
#4
AIKO-A800-GRH78Dw leads by 10 places
05
Open the full database
More useful comparisons
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE66-GD615
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE66-GD610
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE66-GD605
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE66-GD600
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE54-HD505
9 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-BE66-GD595 vs Maxeon SPR-BE54-HD500
9 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Maxeon SPR-BE66-GD595 or AIKO AIKO-A800-GRH78Dw?
According to our database: AIKO AIKO-A800-GRH78Dw has higher module efficiency (24.90% vs 24.00%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-BE66-GD595 and AIKO AIKO-A800-GRH78Dw?
Maxeon SPR-BE66-GD595 has a module efficiency of 24.00%, while AIKO AIKO-A800-GRH78Dw is 24.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-BE66-GD595 use vs AIKO AIKO-A800-GRH78Dw?
Maxeon SPR-BE66-GD595 uses Back Contact cells; AIKO AIKO-A800-GRH78Dw uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-BE66-GD595 and AIKO AIKO-A800-GRH78Dw?
Maxeon SPR-BE66-GD595 has a 40 years power warranty; AIKO AIKO-A800-GRH78Dw has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Maxeon SPR-BE66-GD595 and AIKO AIKO-A800-GRH78Dw bifacial panels?
Both Maxeon SPR-BE66-GD595 and AIKO AIKO-A800-GRH78Dw are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 17 Maxeon offers · See 138 AIKO offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.