Skip to main content
410W vs LEXRON 600W 5 of 19 identical Swap Change panels

Lexron 410W vs Lexron LEXRON 600W

Lexron 410W
Lexron
410W
410 Wp 20.61 % PERC
VS
Lexron
LEXRON 600W
600 Wp 23.23 % TOPCon
The verdict

LEXRON 600W leads on the differences that matter

The largest is module efficiency: 2.62 pp more efficient. 5 of 19 comparable parameters are identical.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs
01

What actually differs

14 of 19 parameters
Parameter 410W LEXRON 600W Difference
Module efficiency 20.61 % 23.23 % 2.62 pp more efficient
Rated power 410 Wp 600 Wp 190 W more power
Power density 206.1 Wp/m² 232.3 Wp/m² 26.1 Wp/m² higher
Weight 22.0 kg 28.0 kg 6.0 kg lighter
Weight per kWp 53.7 kg/kWp 46.7 kg/kWp 7.0 kg/kWp lighter
Short-circuit current 10.42 A 14.58 A 4.16 A apart
Module area 1.989 m² 2.583 m² 0.594 m² apart
Cell technology PERC TOPCon PERC vs TOPCon
Open-circuit voltage 49.82 V 52.08 V 2.26 V apart
Current at max power 9.87 A 13.82 A 3.95 A apart
Cell count 72 144 72 cells apart
Annual degradation 0.45 %/yr 0.40 %/yr 0.05 %/yr slower
Dimensions 1987x1001x35 mm 2278x1134x35 mm 1987x1001x35 mm vs 2278x1134x35 mm
Voltage at max power 41.52 V 43.40 V 1.88 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.350 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
410W
13,502 kWh
LEXRON 600W
20,131 kWh
Lifetime gap
6,629 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 410W LEXRON 600W
Standard test conditions 25 °C 100.0% of rated power 410 W 600 W
Cool, bright day 40 °C 94.8% of rated power 388 W 569 W
Typical summer roof 55 °C 89.5% of rated power 367 W 537 W
Hot roof 70 °C 84.2% of rated power 345 W 506 W
03

Full specification

Parameter 410W LEXRON 600W Difference
Power and efficiency
Rated power 410 Wp 600 Wp +190 W for LEXRON 600W
Module efficiency 20.61 % 23.23 % +2.62 pp for LEXRON 600W
Power density 206.1 Wp/m² 232.3 Wp/m² +26.1 Wp/m² for LEXRON 600W
Open-circuit voltage 49.82 V 52.08 V 2.26 V apart
Voltage at max power 41.52 V 43.40 V 1.88 V apart
Short-circuit current 10.42 A 14.58 A 4.16 A apart
Current at max power 9.87 A 13.82 A 3.95 A apart
Temperature
Temperature coefficient -0.350 %/°C -0.350 %/°C Same
Mechanical
Dimensions 1987x1001x35 mm 2278x1134x35 mm 1987x1001x35 mm vs 2278x1134x35 mm
Module area 1.989 m² 2.583 m² 0.594 m² apart
Weight 22.0 kg 28.0 kg -6.0 kg for 410W
Weight per kWp 53.7 kg/kWp 46.7 kg/kWp -7.0 kg/kWp for LEXRON 600W
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.45 %/yr 0.40 %/yr -0.05 %/yr for LEXRON 600W
Technology
Cell technology PERC TOPCon PERC vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 72 144 72 cells apart
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#11,082 vs #1,252
LEXRON 600W leads by 9,830 places
Power density
#11,095 vs #1,252
LEXRON 600W leads by 9,843 places
Heat behaviour
#10,419 vs #10,419
Tied - the same position in the database
Weight
#7,662 vs #1,298
LEXRON 600W leads by 6,364 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#11,373 vs #2,856
LEXRON 600W leads by 8,517 places
05

More useful comparisons

Open the full database
Same series, other bin
Lexron
Lexron 410W vs Lexron 430W
4 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 410W vs Lexron 425W
3 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 410W vs Lexron 420W
3 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 410W vs Lexron 415W
One difference: module efficiency
Same series, other bin
Lexron
Lexron 410W vs Lexron 405W
One difference: module efficiency
Same series, other bin
Lexron
Lexron LEXRON 600W vs Lexron LEXRON 595W
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Lexron 410W or Lexron LEXRON 600W?
According to our database: Lexron LEXRON 600 W has higher module efficiency (23.23% vs 20.61%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Lexron 410W and Lexron LEXRON 600W?
Lexron 410 W has a module efficiency of 20.61%, while Lexron LEXRON 600 W is 23.23%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Lexron 410W use vs Lexron LEXRON 600W?
Lexron 410 W uses PERC cells; Lexron LEXRON 600 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Lexron 410W and Lexron LEXRON 600W?
Lexron 410 W has a 30 years power warranty; Lexron LEXRON 600 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.