Skip to main content
405W vs LEXRON 600W 5 of 19 identical Swap Change panels

Lexron 405W vs Lexron LEXRON 600W

Lexron 405W
Lexron
405W
405 Wp 20.36 % PERC
VS
Lexron
LEXRON 600W
600 Wp 23.23 % TOPCon
The verdict

LEXRON 600W leads on the differences that matter

The largest is module efficiency: 2.87 pp more efficient. 5 of 19 comparable parameters are identical.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs
01

What actually differs

14 of 19 parameters
Parameter 405W LEXRON 600W Difference
Module efficiency 20.36 % 23.23 % 2.87 pp more efficient
Rated power 405 Wp 600 Wp 195 W more power
Power density 203.6 Wp/m² 232.3 Wp/m² 28.6 Wp/m² higher
Weight 22.0 kg 28.0 kg 6.0 kg lighter
Weight per kWp 54.3 kg/kWp 46.7 kg/kWp 7.7 kg/kWp lighter
Short-circuit current 10.32 A 14.58 A 4.26 A apart
Module area 1.989 m² 2.583 m² 0.594 m² apart
Cell technology PERC TOPCon PERC vs TOPCon
Open-circuit voltage 49.66 V 52.08 V 2.42 V apart
Current at max power 9.79 A 13.82 A 4.03 A apart
Cell count 72 144 72 cells apart
Annual degradation 0.45 %/yr 0.40 %/yr 0.05 %/yr slower
Voltage at max power 41.38 V 43.40 V 2.02 V apart
Dimensions 1987x1001x35 mm 2278x1134x35 mm 1987x1001x35 mm vs 2278x1134x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.350 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
405W
13,337 kWh
LEXRON 600W
20,131 kWh
Lifetime gap
6,794 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 405W LEXRON 600W
Standard test conditions 25 °C 100.0% of rated power 405 W 600 W
Cool, bright day 40 °C 94.8% of rated power 384 W 569 W
Typical summer roof 55 °C 89.5% of rated power 362 W 537 W
Hot roof 70 °C 84.2% of rated power 341 W 506 W
03

Full specification

Parameter 405W LEXRON 600W Difference
Power and efficiency
Rated power 405 Wp 600 Wp +195 W for LEXRON 600W
Module efficiency 20.36 % 23.23 % +2.87 pp for LEXRON 600W
Power density 203.6 Wp/m² 232.3 Wp/m² +28.6 Wp/m² for LEXRON 600W
Open-circuit voltage 49.66 V 52.08 V 2.42 V apart
Voltage at max power 41.38 V 43.40 V 2.02 V apart
Short-circuit current 10.32 A 14.58 A 4.26 A apart
Current at max power 9.79 A 13.82 A 4.03 A apart
Temperature
Temperature coefficient -0.350 %/°C -0.350 %/°C Same
Mechanical
Dimensions 1987x1001x35 mm 2278x1134x35 mm 1987x1001x35 mm vs 2278x1134x35 mm
Module area 1.989 m² 2.583 m² 0.594 m² apart
Weight 22.0 kg 28.0 kg -6.0 kg for 405W
Weight per kWp 54.3 kg/kWp 46.7 kg/kWp -7.7 kg/kWp for LEXRON 600W
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.45 %/yr 0.40 %/yr -0.05 %/yr for LEXRON 600W
Technology
Cell technology PERC TOPCon PERC vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 72 144 72 cells apart
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#11,709 vs #1,252
LEXRON 600W leads by 10,457 places
Power density
#11,674 vs #1,252
LEXRON 600W leads by 10,422 places
Heat behaviour
#10,419 vs #10,419
Tied - the same position in the database
Weight
#8,586 vs #1,298
LEXRON 600W leads by 7,288 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#11,615 vs #2,856
LEXRON 600W leads by 8,759 places
05

More useful comparisons

Open the full database
Same series, other bin
Lexron
Lexron 405W vs Lexron 430W
4 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 405W vs Lexron 425W
4 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 405W vs Lexron 420W
3 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 405W vs Lexron 415W
3 differences, the largest is module efficiency
Same series, other bin
Lexron
Lexron 405W vs Lexron 410W
One difference: module efficiency
Same series, other bin
Lexron
Lexron LEXRON 600W vs Lexron LEXRON 595W
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Lexron 405W or Lexron LEXRON 600W?
According to our database: Lexron LEXRON 600 W has higher module efficiency (23.23% vs 20.36%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Lexron 405W and Lexron LEXRON 600W?
Lexron 405 W has a module efficiency of 20.36%, while Lexron LEXRON 600 W is 23.23%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Lexron 405W use vs Lexron LEXRON 600W?
Lexron 405 W uses PERC cells; Lexron LEXRON 600 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Lexron 405W and Lexron LEXRON 600W?
Lexron 405 W has a 30 years power warranty; Lexron LEXRON 600 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.