Skip to main content
F4-EU vs F2-EU 18 of 19 identical Swap Change panels

Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM485N-48QL6-DB-F2-EU

Jinko Solar JKM485N-48QL6-DB-F4-EU
JKM485N-48QL6-DB-F4-EU
485 Wp 24.27 % N-type
VS
JKM485N-48QL6-DB-F2-EU
485 Wp 24.27 % TOPCon
The verdict

One difference, none of them an advantage

The largest is cell technology: N-type vs TOPCon. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter F4-EU F2-EU Difference
Cell technology N-type TOPCon N-type vs TOPCon
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.260 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
F4-EU
16,399 kWh
F2-EU
16,399 kWh
Lifetime gap
No difference
Output when it is hot
Rated power carried across the range a module actually sees
Scenario F4-EU F2-EU
Standard test conditions 25 °C 100.0% of rated power 485 W 485 W
Cool, bright day 40 °C 96.1% of rated power 466 W 466 W
Typical summer roof 55 °C 92.2% of rated power 447 W 447 W
Hot roof 70 °C 88.3% of rated power 428 W 428 W
03

Full specification

Parameter F4-EU F2-EU Difference
Power and efficiency
Rated power 485 Wp 485 Wp Same
Module efficiency 24.27 % 24.27 % Same
Power density 242.7 Wp/m² 242.7 Wp/m² Same
Open-circuit voltage 36.94 V 36.94 V Same
Voltage at max power 31.50 V 31.50 V Same
Short-circuit current 15.94 A 15.94 A Same
Current at max power 15.40 A 15.40 A Same
Temperature
Temperature coefficient -0.260 %/°C -0.260 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 24.4 kg 24.4 kg Same
Weight per kWp 50.3 kg/kWp 50.3 kg/kWp Same
Warranty and degradation
Product warranty 25 yrs 25 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr 0.35 %/yr Same
Technology
Cell technology N-type TOPCon N-type vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 192 192 Same
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#164 vs #164
Tied - the same position in the database
Power density
#140 vs #140
Tied - the same position in the database
Heat behaviour
#511 vs #511
Tied - the same position in the database
Weight
#3,707 vs #3,707
Tied - the same position in the database
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#2,974 vs #2,974
Tied - the same position in the database
05

More useful comparisons

Open the full database
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM650-670N-66QL6-BDV (670W class)
11 differences, the largest is rated power
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM650-670N-66QL6-BDV-F2-EU (670W)
11 differences, the largest is rated power
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM645-670N-66QL6-BDV-L
11 differences, the largest is rated power
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM670N-66QL6-BDX
13 differences, the largest is rated power
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM670N-66QL6-BDV-F4-EU
11 differences, the largest is rated power
Same series, other bin
Jinko Solar JKM485N-48QL6-DB-F4-EU vs Jinko Solar JKM650-670N-66QL6-BDV (665W class)
11 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Jinko Solar JKM485N-48QL6-DB-F4-EU or Jinko Solar JKM485N-48QL6-DB-F2-EU?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Jinko Solar JKM485N-48QL6-DB-F4-EU and Jinko Solar JKM485N-48QL6-DB-F2-EU?
Jinko Solar JKM485N-48QL6-DB-F4-EU has a module efficiency of 24.27%, while Jinko Solar JKM485N-48QL6-DB-F2-EU is 24.27%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Jinko Solar JKM485N-48QL6-DB-F4-EU use vs Jinko Solar JKM485N-48QL6-DB-F2-EU?
Jinko Solar JKM485N-48QL6-DB-F4-EU uses N-type cells; Jinko Solar JKM485N-48QL6-DB-F2-EU uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Jinko Solar JKM485N-48QL6-DB-F4-EU and Jinko Solar JKM485N-48QL6-DB-F2-EU?
Jinko Solar JKM485N-48QL6-DB-F4-EU has a 30 years power warranty; Jinko Solar JKM485N-48QL6-DB-F2-EU has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 174 Jinko Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.