Skip to main content
710/LB vs 740/LB 13 of 19 identical Swap Change panels

JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-740/LB

JA Solar JAM66D46-710/LB
JAM66D46-710/LB
710 Wp 22.90 % TOPCon Bifacial
VS
JA Solar JAM66D46-740/LB
JAM66D46-740/LB
740 Wp 23.80 % TOPCon Bifacial
The verdict

740/LB leads on the differences that matter

The largest is module efficiency: 0.90 pp more efficient. 13 of 19 comparable parameters are identical.

See all 6 differences
How alike are they
13 of 19 comparable
parameters are identical
identical differs
01

What actually differs

6 of 19 parameters
Parameter 710/LB 740/LB Difference
Module efficiency 22.90 % 23.80 % 0.90 pp more efficient
Power density 228.6 Wp/m² 238.2 Wp/m² 9.7 Wp/m² higher
Rated power 710 Wp 740 Wp 30 W more power
Open-circuit voltage 48.16 V 49.80 V 1.64 V apart
Weight per kWp 53.8 kg/kWp 51.6 kg/kWp 2.2 kg/kWp lighter
Voltage at max power 40.40 V 41.96 V 1.56 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
710/LB
23,822 kWh
740/LB
24,828 kWh
Lifetime gap
1,006 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 710/LB 740/LB
Standard test conditions 25 °C 100.0% of rated power 710 W 740 W
Cool, bright day 40 °C 95.7% of rated power 679 W 708 W
Typical summer roof 55 °C 91.3% of rated power 648 W 676 W
Hot roof 70 °C 87.0% of rated power 617 W 643 W
03

Full specification

Parameter 710/LB 740/LB Difference
Power and efficiency
Rated power 710 Wp 740 Wp +30 W for 740/LB
Module efficiency 22.90 % 23.80 % +0.90 pp for 740/LB
Power density 228.6 Wp/m² 238.2 Wp/m² +9.7 Wp/m² for 740/LB
Open-circuit voltage 48.16 V 49.80 V 1.64 V apart
Voltage at max power 40.40 V 41.96 V 1.56 V apart
Short-circuit current 18.47 A 18.73 A Effectively the same
Current at max power 17.32 A 17.64 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2384x1303x33 mm 2384x1303x33 mm Same
Module area 3.106 m² 3.106 m² Same
Weight 38.2 kg 38.2 kg Same
Weight per kWp 53.8 kg/kWp 51.6 kg/kWp -2.2 kg/kWp for 740/LB
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#2,359 vs #433
740/LB leads by 1,926 places
Power density
#2,474 vs #431
740/LB leads by 2,043 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#7,882 vs #4,997
740/LB leads by 2,885 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#817 vs #185
740/LB leads by 632 places
05

More useful comparisons

Open the full database
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-735/LB
5 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-730/LB
5 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-725/LB
4 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-720/LB
3 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-715/LB
The same specification on paper
Same series, other bin
JA Solar JAM66D46-710/LB vs JA Solar JAM66D46-705/LB
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: JA Solar JAM66D46-710/LB or JA Solar JAM66D46-740/LB?
According to our database: JA Solar JAM66D46-740/LB has higher module efficiency (23.80% vs 22.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of JA Solar JAM66D46-710/LB and JA Solar JAM66D46-740/LB?
JA Solar JAM66D46-710/LB has a module efficiency of 22.90%, while JA Solar JAM66D46-740/LB is 23.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does JA Solar JAM66D46-710/LB use vs JA Solar JAM66D46-740/LB?
JA Solar JAM66D46-710/LB uses TOPCon cells; JA Solar JAM66D46-740/LB uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on JA Solar JAM66D46-710/LB and JA Solar JAM66D46-740/LB?
JA Solar JAM66D46-710/LB has a 30 years power warranty; JA Solar JAM66D46-740/LB has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are JA Solar JAM66D46-710/LB and JA Solar JAM66D46-740/LB bifacial panels?
Both JA Solar JAM66D46-710/LB and JA Solar JAM66D46-740/LB are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 390 JA Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.