Skip to main content
JAM54D41-455/LB vs LR7-54HVB-485M 7 of 18 identical Swap Change panels

JA Solar JAM54D41-455/LB vs Longi Solar LR7-54HVB-485M

JA Solar JAM54D41-455/LB
JAM54D41-455/LB
455 Wp 22.80 % TOPCon Bifacial
VS
Longi Solar LR7-54HVB-485M
LR7-54HVB-485M
485 Wp 23.80 % N-type
The verdict

LR7-54HVB-485M leads on the differences that matter

The largest is module efficiency: 1.00 pp more efficient. 7 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 11 differences
How alike are they
7 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 18 parameters
Parameter JAM54D41-455/LB LR7-54HVB-485M Difference
Module efficiency 22.80 % 23.80 % 1.00 pp more efficient
Temperature coefficient -0.290 %/°C -0.260 %/°C 0.030 %/°C better in heat
Power density 227.7 Wp/m² 237.6 Wp/m² 9.9 Wp/m² higher
Rated power 455 Wp 485 Wp 30 W more power
Weight per kWp 48.4 kg/kWp 44.5 kg/kWp 3.8 kg/kWp lighter
Cell technology TOPCon N-type TOPCon vs N-type
Module area 1.998 m² 2.041 m² 0.043 m² apart
Annual degradation 0.40 %/yr 0.35 %/yr 0.05 %/yr slower
Bifacial Yes No Yes vs No
Dimensions 1762x1134x30 mm 1800x1134x30 mm 1762x1134x30 mm vs 1800x1134x30 mm
Current at max power 13.99 A 14.53 A 0.54 A apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
JAM54D41-455/LB
15,266 kWh
LR7-54HVB-485M
16,399 kWh
Lifetime gap
1,133 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario JAM54D41-455/LB LR7-54HVB-485M
Standard test conditions 25 °C 100.0% of rated power 455 W 485 W
Cool, bright day 40 °C 95.7% of rated power 435 W 466 W
Typical summer roof 55 °C 91.3% of rated power 415 W 447 W
Hot roof 70 °C 87.0% of rated power 396 W 428 W
03

Full specification

Parameter JAM54D41-455/LB LR7-54HVB-485M Difference
Power and efficiency
Rated power 455 Wp 485 Wp +30 W for LR7-54HVB-485M
Module efficiency 22.80 % 23.80 % +1.00 pp for LR7-54HVB-485M
Power density 227.7 Wp/m² 237.6 Wp/m² +9.9 Wp/m² for LR7-54HVB-485M
Open-circuit voltage 39.50 V 40.40 V Effectively the same
Voltage at max power 32.83 V 33.40 V Effectively the same
Short-circuit current 14.95 A 15.23 A Effectively the same
Current at max power 13.99 A 14.53 A 0.54 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.260 %/°C +0.030 %/°C for LR7-54HVB-485M
Mechanical
Dimensions 1762x1134x30 mm 1800x1134x30 mm 1762x1134x30 mm vs 1800x1134x30 mm
Module area 1.998 m² 2.041 m² 0.043 m² apart
Weight 22.0 kg 21.6 kg Effectively the same
Weight per kWp 48.4 kg/kWp 44.5 kg/kWp -3.8 kg/kWp for LR7-54HVB-485M
Warranty and degradation
Product warranty 15 yrs - Not published by Longi Solar
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.35 %/yr -0.05 %/yr for LR7-54HVB-485M
Technology
Cell technology TOPCon N-type TOPCon vs N-type
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes No Yes vs No
04

Against the whole database

14,354 panels
Efficiency
#2,864 vs #514
LR7-54HVB-485M leads by 2,350 places
Power density
#3,046 vs #582
LR7-54HVB-485M leads by 2,464 places
Heat behaviour
#2,288 vs #521
LR7-54HVB-485M leads by 1,767 places
Weight
#2,238 vs #469
LR7-54HVB-485M leads by 1,769 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#8,016 vs #8,954
JAM54D41-455/LB leads by 938 places
05

More useful comparisons

Open the full database
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D40-475/LB
6 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D40-470/LB
3 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D40-465/LB
3 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D40-460/LB
2 differences, the largest is product warranty
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D40-455/LB
One difference: product warranty
Same series, other bin
JA Solar JAM54D41-455/LB vs JA Solar JAM54D41 455/LB
2 differences, the largest is product warranty
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: JA Solar JAM54D41-455/LB or Longi Solar LR7-54HVB-485M?
According to our database: Longi Solar LR7-54HVB-485M has higher module efficiency (23.80% vs 22.80%); Longi Solar LR7-54HVB-485M tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of JA Solar JAM54D41-455/LB and Longi Solar LR7-54HVB-485M?
JA Solar JAM54D41-455/LB has a module efficiency of 22.80%, while Longi Solar LR7-54HVB-485M is 23.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does JA Solar JAM54D41-455/LB use vs Longi Solar LR7-54HVB-485M?
JA Solar JAM54D41-455/LB uses TOPCon cells; Longi Solar LR7-54HVB-485M uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on JA Solar JAM54D41-455/LB and Longi Solar LR7-54HVB-485M?
JA Solar JAM54D41-455/LB has a 30 years power warranty; Longi Solar LR7-54HVB-485M has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are JA Solar JAM54D41-455/LB and Longi Solar LR7-54HVB-485M bifacial panels?
JA Solar JAM54D41-455/LB is bifacial (captures light from both faces); Longi Solar LR7-54HVB-485M is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare JA Solar and Longi Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 251 JA Solar offers · See 118 Longi Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.