Skip to main content
460/LR vs 475/LR 15 of 19 identical Swap Change panels

JA Solar JAM54D40-460/LR vs JA Solar JAM54D40-475/LR

JA Solar JAM54D40-460/LR
JAM54D40-460/LR
460 Wp 23.00 % N-type
VS
JA Solar JAM54D40-475/LR
JAM54D40-475/LR
475 Wp 23.80 % N-type
The verdict

475/LR leads on the differences that matter

The largest is module efficiency: 0.80 pp more efficient. 15 of 19 comparable parameters are identical.

See all 4 differences
How alike are they
15 of 19 comparable
parameters are identical
identical differs
01

What actually differs

4 of 19 parameters
Parameter 460/LR 475/LR Difference
Module efficiency 23.00 % 23.80 % 0.80 pp more efficient
Power density 230.2 Wp/m² 237.7 Wp/m² 7.5 Wp/m² higher
Rated power 460 Wp 475 Wp 15 W more power
Voltage at max power 33.17 V 34.18 V 1.01 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
460/LR
15,434 kWh
475/LR
15,937 kWh
Lifetime gap
503 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 460/LR 475/LR
Standard test conditions 25 °C 100.0% of rated power 460 W 475 W
Cool, bright day 40 °C 95.7% of rated power 440 W 454 W
Typical summer roof 55 °C 91.3% of rated power 420 W 434 W
Hot roof 70 °C 87.0% of rated power 400 W 413 W
03

Full specification

Parameter 460/LR 475/LR Difference
Power and efficiency
Rated power 460 Wp 475 Wp +15 W for 475/LR
Module efficiency 23.00 % 23.80 % +0.80 pp for 475/LR
Power density 230.2 Wp/m² 237.7 Wp/m² +7.5 Wp/m² for 475/LR
Open-circuit voltage 39.70 V 40.55 V Effectively the same
Voltage at max power 33.17 V 34.18 V 1.01 V apart
Short-circuit current 14.64 A 14.67 A Effectively the same
Current at max power 13.87 A 13.90 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 22.0 kg 22.0 kg Same
Weight per kWp 47.8 kg/kWp 46.3 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#1,919 vs #433
475/LR leads by 1,486 places
Power density
#1,876 vs #467
475/LR leads by 1,409 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#1,924 vs #1,117
475/LR leads by 807 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#7,344 vs #5,786
475/LR leads by 1,558 places
05

More useful comparisons

Open the full database
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54D40-470/LR
3 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54D40-465/LR
One difference: module efficiency
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54S40-460/LR
3 differences, the largest is weight per kwp
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54S40-455/LR
4 differences, the largest is weight
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54D41-455/LR
2 differences, the largest is cell technology
Same series, other bin
JA Solar JAM54D40-460/LR vs JA Solar JAM54D40-455/LR
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: JA Solar JAM54D40-460/LR or JA Solar JAM54D40-475/LR?
According to our database: JA Solar JAM54D40-475/LR has higher module efficiency (23.80% vs 23.00%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of JA Solar JAM54D40-460/LR and JA Solar JAM54D40-475/LR?
JA Solar JAM54D40-460/LR has a module efficiency of 23.00%, while JA Solar JAM54D40-475/LR is 23.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does JA Solar JAM54D40-460/LR use vs JA Solar JAM54D40-475/LR?
JA Solar JAM54D40-460/LR uses N-type cells; JA Solar JAM54D40-475/LR uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on JA Solar JAM54D40-460/LR and JA Solar JAM54D40-475/LR?
JA Solar JAM54D40-460/LR has a 30 years power warranty; JA Solar JAM54D40-475/LR has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 389 JA Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.