Module efficiency
23.70 %
22.47 %
1.23 pp more efficient
Rated power
640 Wp
270 Wp
370 W more power
Power density
236.9 Wp/m²
224.8 Wp/m²
12.2 Wp/m² higher
Weight
32.5 kg
14.3 kg
18.2 kg lighter
Product warranty
12 yrs
30 yrs
18 yrs longer
Temperature coefficient
-0.280 %/°C
-0.260 %/°C
0.020 %/°C better in heat
Open-circuit voltage
49.75 V
23.67 V
26.08 V apart
Module area
2.701 m²
1.201 m²
1.500 m² apart
Short-circuit current
16.33 A
14.58 A
1.75 A apart
Cell technology
N-type
Back Contact
N-type vs Back Contact
Voltage at max power
41.38 V
20.23 V
21.15 V apart
Current at max power
15.47 A
13.35 A
2.12 A apart
Cell count
132
64
68 cells apart
Weight per kWp
50.8 kg/kWp
53.0 kg/kWp
2.2 kg/kWp lighter
Dimensions
2382x1134x30 mm
1560x770x35 mm
2382x1134x30 mm vs 1560x770x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
2.1-640
21,076 kWh
1.2 FullBlack 270W
8,891 kWh
Lifetime gap
12,185 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
2.1-640
1.2 FullBlack 270W
Standard test conditions
25 °C
100.0% of rated power
640 W
270 W
Cool, bright day
40 °C
95.8% of rated power
613 W
259 W
Typical summer roof
55 °C
91.6% of rated power
586 W
249 W
Hot roof
70 °C
87.4% of rated power
559 W
238 W
03
Full specification
Parameter
2.1-640
1.2 FullBlack 270W
Difference
Power and efficiency
Rated power
640 Wp
270 Wp
+370 W for 2.1-640
Module efficiency
23.70 %
22.47 %
+1.23 pp for 2.1-640
Power density
236.9 Wp/m²
224.8 Wp/m²
+12.2 Wp/m² for 2.1-640
Open-circuit voltage
49.75 V
23.67 V
26.08 V apart
Voltage at max power
41.38 V
20.23 V
21.15 V apart
Short-circuit current
16.33 A
14.58 A
1.75 A apart
Current at max power
15.47 A
13.35 A
2.12 A apart
Temperature
Temperature coefficient
-0.280 %/°C
-0.260 %/°C
+0.020 %/°C for 1.2 FullBlack 270W
Mechanical
Dimensions
2382x1134x30 mm
1560x770x35 mm
2382x1134x30 mm vs 1560x770x35 mm
Module area
2.701 m²
1.201 m²
1.500 m² apart
Weight
32.5 kg
14.3 kg
-18.2 kg for 1.2 FullBlack 270W
Weight per kWp
50.8 kg/kWp
53.0 kg/kWp
-2.2 kg/kWp for 2.1-640
Warranty and degradation
Product warranty
12 yrs
30 yrs
+18 yrs for 1.2 FullBlack 270W
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.45 %/yr
0.45 %/yr
Same
Technology
Cell technology
N-type
Back Contact
N-type vs Back Contact
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
64
68 cells apart
Bifacial
Yes
Yes
Same
04
13,953 panels
Against the whole database
Efficiency
#511
vs
#4,522
2.1-640 leads by 4,011 places
Power density
#515
vs
#4,443
2.1-640 leads by 3,928 places
Heat behaviour
#1,290
vs
#511
1.2 FullBlack 270W leads by 779 places
Weight
#4,174
vs
#6,643
2.1-640 leads by 2,469 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#1,515
vs
#10,521
2.1-640 leads by 9,006 places
05
Open the full database
More useful comparisons
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 2.1 640W
One difference: cell technology
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 2.1-635
One difference: module efficiency
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 2.1 635W
2 differences, the largest is cell technology
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 1.2 FullBlack 280W
14 differences, the largest is rated power
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 1.2-280
14 differences, the largest is rated power
Same series, other bin
Heckert Solar
Heckert Solar ZEUS 2.1-640 vs Heckert Solar ZEUS 1.2 FullBlack 275W
14 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Heckert Solar ZEUS 2.1-640 or Heckert Solar ZEUS 1.2 FullBlack 270W?
According to our database: Heckert Solar ZEUS 2.1-640 has higher module efficiency (23.70% vs 22.47%); Heckert Solar ZEUS 1.2 FullBlack 270 W tolerates heat better (temp coeff -0.260%/°C vs -0.280%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Heckert Solar ZEUS 2.1-640 and Heckert Solar ZEUS 1.2 FullBlack 270W?
Heckert Solar ZEUS 2.1-640 has a module efficiency of 23.70%, while Heckert Solar ZEUS 1.2 FullBlack 270 W is 22.47%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Heckert Solar ZEUS 2.1-640 use vs Heckert Solar ZEUS 1.2 FullBlack 270W?
Heckert Solar ZEUS 2.1-640 uses N-type cells; Heckert Solar ZEUS 1.2 FullBlack 270 W uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Heckert Solar ZEUS 2.1-640 and Heckert Solar ZEUS 1.2 FullBlack 270W?
Heckert Solar ZEUS 2.1-640 has a 30 years power warranty; Heckert Solar ZEUS 1.2 FullBlack 270 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Heckert Solar ZEUS 2.1-640 and Heckert Solar ZEUS 1.2 FullBlack 270W bifacial panels?
Both Heckert Solar ZEUS 2.1-640 and Heckert Solar ZEUS 1.2 FullBlack 270 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 16 Heckert Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.