Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON XL-G2.3 / BFG 610
VS
The verdict
13 differences, and they point both ways
The largest is rated power: 180 W more power. 6 of 19 comparable parameters are identical.
See all 13 differencesHow alike are they
6
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
13 of 19 parameters
What actually differs
Parameter
BLK M-G2+ 430
XL-G2.3 / BFG 610
Difference
Rated power
430 Wp
610 Wp
180 W more power
Performance warranty
25 yrs
30 yrs
5 yrs longer
Weight
21.2 kg
35.4 kg
14.2 kg lighter
Weight per kWp
49.3 kg/kWp
58.0 kg/kWp
8.7 kg/kWp lighter
Product warranty
25 yrs
12 yrs
13 yrs longer
Open-circuit voltage
39.32 V
56.11 V
16.79 V apart
Module area
1.953 m²
2.792 m²
0.839 m² apart
Temperature coefficient
-0.290 %/°C
-0.300 %/°C
0.010 %/°C better in heat
Module efficiency
22.00 %
21.80 %
0.20 pp more efficient
Voltage at max power
32.94 V
47.10 V
14.16 V apart
Cell count
108
156
48 cells apart
Bifacial
No
Yes
No vs Yes
Dimensions
1722x1134x30 mm
2462x1134x35 mm
1722x1134x30 mm vs 2462x1134x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
BLK M-G2+ 430
14,507 kWh
XL-G2.3 / BFG 610
20,580 kWh
Lifetime gap
6,073 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
BLK M-G2+ 430
XL-G2.3 / BFG 610
Standard test conditions
25 °C
100.0% of rated power
430 W
610 W
Cool, bright day
40 °C
95.5% of rated power
411 W
583 W
Typical summer roof
55 °C
91.0% of rated power
393 W
555 W
Hot roof
70 °C
86.5% of rated power
374 W
528 W
03
Full specification
Parameter
BLK M-G2+ 430
XL-G2.3 / BFG 610
Difference
Power and efficiency
Rated power
430 Wp
610 Wp
+180 W for XL-G2.3 / BFG 610
Module efficiency
22.00 %
21.80 %
+0.20 pp for BLK M-G2+ 430
Power density
220.2 Wp/m²
218.5 Wp/m²
Effectively the same
Open-circuit voltage
39.32 V
56.11 V
16.79 V apart
Voltage at max power
32.94 V
47.10 V
14.16 V apart
Short-circuit current
13.74 A
13.65 A
Effectively the same
Current at max power
13.05 A
12.95 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.300 %/°C
+0.010 %/°C for BLK M-G2+ 430
Mechanical
Dimensions
1722x1134x30 mm
2462x1134x35 mm
1722x1134x30 mm vs 2462x1134x35 mm
Module area
1.953 m²
2.792 m²
0.839 m² apart
Weight
21.2 kg
35.4 kg
-14.2 kg for BLK M-G2+ 430
Weight per kWp
49.3 kg/kWp
58.0 kg/kWp
-8.7 kg/kWp for BLK M-G2+ 430
Warranty and degradation
Product warranty
25 yrs
12 yrs
+13 yrs for BLK M-G2+ 430
Performance warranty
25 yrs
30 yrs
+5 yrs for XL-G2.3 / BFG 610
Annual degradation
0.33 %/yr
0.33 %/yr
Same
Technology
Cell technology
N-type
N-type
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
156
48 cells apart
Bifacial
No
Yes
No vs Yes
04
14,354 panels
Against the whole database
Efficiency
#6,713
vs
#7,225
BLK M-G2+ 430 leads by 512 places
Power density
#6,678
vs
#7,152
BLK M-G2+ 430 leads by 474 places
Heat behaviour
#2,288
vs
#6,298
BLK M-G2+ 430 leads by 4,010 places
Weight
#2,884
vs
#11,793
BLK M-G2+ 430 leads by 8,909 places
Warranty
#10,073
vs
#31
XL-G2.3 / BFG 610 leads by 10,042 places
Overall
#8,833
vs
#4,402
XL-G2.3 / BFG 610 leads by 4,431 places
05
Open the full database
More useful comparisons
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)
8 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2+ 440
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2.D1+/AC (Power class 435W)
6 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2+ 435
One difference: module efficiency
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2.C1+/AC (Power class 430W)
5 differences, the largest is weight per kwp
Same series, other bin
Q-Cells Q.TRON BLK M-G2+ 430 vs Q-Cells Q.TRON BLK M-G2.E1+/AC (Power class 425W)
6 differences, the largest is weight per kwp
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Q-Cells Q.TRON BLK M-G2+ 430 or Q-Cells Q.TRON XL-G2.3 / BFG 610?
According to our database: Q-Cells Q.TRON BLK M-G2+ 430 has higher module efficiency (22.00% vs 21.80%); Q-Cells Q.TRON BLK M-G2+ 430 tolerates heat better (temp coeff -0.290%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Q-Cells Q.TRON BLK M-G2+ 430 and Q-Cells Q.TRON XL-G2.3 / BFG 610?
Q-Cells Q.TRON BLK M-G2+ 430 has a module efficiency of 22.00%, while Q-Cells Q.TRON XL-G2.3 / BFG 610 is 21.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Q-Cells Q.TRON BLK M-G2+ 430 use vs Q-Cells Q.TRON XL-G2.3 / BFG 610?
Q-Cells Q.TRON BLK M-G2+ 430 uses N-type cells; Q-Cells Q.TRON XL-G2.3 / BFG 610 uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Q-Cells Q.TRON BLK M-G2+ 430 and Q-Cells Q.TRON XL-G2.3 / BFG 610?
Q-Cells Q.TRON BLK M-G2+ 430 has a 25 years power warranty; Q-Cells Q.TRON XL-G2.3 / BFG 610 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Q-Cells Q.TRON BLK M-G2+ 430 and Q-Cells Q.TRON XL-G2.3 / BFG 610 bifacial panels?
Q-Cells Q.TRON XL-G2.3 / BFG 610 is bifacial (captures light from both faces); Q-Cells Q.TRON BLK M-G2+ 430 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 17 Q-Cells offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.