GCL NT12R/54GDF-515W vs GCL NT12R/54BGDF-520W
VS
The verdict
54BGDF-520W leads on the differences that matter
The largest is module efficiency: 0.22 pp more efficient. 15 of 19 comparable parameters are identical.
See all 4 differencesHow alike are they
15
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
4 of 19 parameters
What actually differs
Parameter
54GDF-515W
54BGDF-520W
Difference
Module efficiency
23.15 %
23.37 %
0.22 pp more efficient
Open-circuit voltage
39.78 V
41.48 V
1.70 V apart
Short-circuit current
16.06 A
15.53 A
0.53 A apart
Voltage at max power
33.75 V
35.02 V
1.27 V apart
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
54GDF-515W
17,279 kWh
54BGDF-520W
17,447 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
54GDF-515W
54BGDF-520W
Standard test conditions
25 °C
100.0% of rated power
515 W
520 W
Cool, bright day
40 °C
95.7% of rated power
493 W
497 W
Typical summer roof
55 °C
91.3% of rated power
470 W
475 W
Hot roof
70 °C
87.0% of rated power
448 W
452 W
03
Full specification
Parameter
54GDF-515W
54BGDF-520W
Difference
Power and efficiency
Rated power
515 Wp
520 Wp
Effectively the same
Module efficiency
23.15 %
23.37 %
+0.22 pp for 54BGDF-520W
Power density
231.5 Wp/m²
233.7 Wp/m²
Effectively the same
Open-circuit voltage
39.78 V
41.48 V
1.70 V apart
Voltage at max power
33.75 V
35.02 V
1.27 V apart
Short-circuit current
16.06 A
15.53 A
0.53 A apart
Current at max power
15.26 A
14.85 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1962x1134x30 mm
1962x1134x30 mm
Same
Module area
2.225 m²
2.225 m²
Same
Weight
27.3 kg
27.3 kg
Same
Weight per kWp
53.0 kg/kWp
52.5 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,503
vs
#930
54BGDF-520W leads by 573 places
Power density
#1,499
vs
#919
54BGDF-520W leads by 580 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#6,762
vs
#6,043
54BGDF-520W leads by 719 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#5,886
vs
#5,503
54BGDF-520W leads by 383 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/54GDF-515W vs GCL GCL-NT12R/54GDF-530
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54GDF-515W vs GCL NT12R/54GDF-525W
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54GDF-515W vs GCL GCL-NT12R/54GDF-525
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54GDF-515W vs GCL NT12R/54GDF-520W
One difference: module efficiency
Same series, other bin
GCL NT12R/54GDF-515W vs GCL GCL-NT12R/54GDF-520
One difference: module efficiency
Same series, other bin
GCL NT12R/54GDF-515W vs GCL NT12R/54BGDF-515W
3 differences, the largest is open-circuit voltage
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/54GDF-515W or GCL NT12R/54BGDF-520W?
According to our database: GCL NT12R/54BGDF-520 W has higher module efficiency (23.37% vs 23.15%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/54GDF-515W and GCL NT12R/54BGDF-520W?
GCL NT12R/54GDF-515 W has a module efficiency of 23.15%, while GCL NT12R/54BGDF-520 W is 23.37%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/54GDF-515W use vs GCL NT12R/54BGDF-520W?
GCL NT12R/54GDF-515 W uses TOPCon cells; GCL NT12R/54BGDF-520 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/54GDF-515W and GCL NT12R/54BGDF-520W?
GCL NT12R/54GDF-515 W has a 30 years power warranty; GCL NT12R/54BGDF-520 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/54GDF-515W and GCL NT12R/54BGDF-520W bifacial panels?
Both GCL NT12R/54GDF-515 W and GCL NT12R/54BGDF-520 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.