Skip to main content
NT12R/54BGDF-515W vs GCL-NT12R/54GDF-525 14 of 19 identical Swap Change panels

GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-525

NT12R/54BGDF-515W
515 Wp 23.15 % TOPCon Bifacial
VS
GCL-NT12R/54GDF-525
525 Wp 23.60 % TOPCon Bifacial
The verdict

GCL-NT12R/54GDF-525 leads on the differences that matter

The largest is module efficiency: 0.45 pp more efficient. 14 of 19 comparable parameters are identical.

See all 5 differences
How alike are they
14 of 19 comparable
parameters are identical
identical differs
01

What actually differs

5 of 19 parameters
Parameter NT12R/54BGDF-515W GCL-NT12R/54GDF-525 Difference
Module efficiency 23.15 % 23.60 % 0.45 pp more efficient
Power density 231.5 Wp/m² 236.0 Wp/m² 4.5 Wp/m² higher
Rated power 515 Wp 525 Wp 10 W more power
Short-circuit current 15.50 A 16.16 A 0.66 A apart
Current at max power 14.82 A 15.35 A 0.53 A apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
NT12R/54BGDF-515W
17,279 kWh
GCL-NT12R/54GDF-525
17,615 kWh
Lifetime gap
336 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario NT12R/54BGDF-515W GCL-NT12R/54GDF-525
Standard test conditions 25 °C 100.0% of rated power 515 W 525 W
Cool, bright day 40 °C 95.7% of rated power 493 W 502 W
Typical summer roof 55 °C 91.3% of rated power 470 W 479 W
Hot roof 70 °C 87.0% of rated power 448 W 456 W
03

Full specification

Parameter NT12R/54BGDF-515W GCL-NT12R/54GDF-525 Difference
Power and efficiency
Rated power 515 Wp 525 Wp +10 W for GCL-NT12R/54GDF-525
Module efficiency 23.15 % 23.60 % +0.45 pp for GCL-NT12R/54GDF-525
Power density 231.5 Wp/m² 236.0 Wp/m² +4.5 Wp/m² for GCL-NT12R/54GDF-525
Open-circuit voltage 41.19 V 40.30 V Effectively the same
Voltage at max power 34.75 V 34.20 V Effectively the same
Short-circuit current 15.50 A 16.16 A 0.66 A apart
Current at max power 14.82 A 15.35 A 0.53 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1962x1134x30 mm 1962x1134x30 mm Same
Module area 2.225 m² 2.225 m² Same
Weight 27.3 kg 27.3 kg Same
Weight per kWp 53.0 kg/kWp 52.0 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#1,503 vs #627
GCL-NT12R/54GDF-525 leads by 876 places
Power density
#1,499 vs #653
GCL-NT12R/54GDF-525 leads by 846 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#6,762 vs #5,417
GCL-NT12R/54GDF-525 leads by 1,345 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#5,886 vs #5,035
GCL-NT12R/54GDF-525 leads by 851 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-530
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54GDF-525W
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54BGDF-520W
One difference: module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54GDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-520
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54GDF-515W
3 differences, the largest is open-circuit voltage
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL NT12R/54BGDF-515W or GCL GCL-NT12R/54GDF-525?
According to our database: GCL GCL-NT12R/54GDF-525 has higher module efficiency (23.60% vs 23.15%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/54BGDF-515W and GCL GCL-NT12R/54GDF-525?
GCL NT12R/54BGDF-515 W has a module efficiency of 23.15%, while GCL GCL-NT12R/54GDF-525 is 23.60%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/54BGDF-515W use vs GCL GCL-NT12R/54GDF-525?
GCL NT12R/54BGDF-515 W uses TOPCon cells; GCL GCL-NT12R/54GDF-525 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/54BGDF-515W and GCL GCL-NT12R/54GDF-525?
GCL NT12R/54BGDF-515 W has a 30 years power warranty; GCL GCL-NT12R/54GDF-525 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/54BGDF-515W and GCL GCL-NT12R/54GDF-525 bifacial panels?
Both GCL NT12R/54BGDF-515 W and GCL GCL-NT12R/54GDF-525 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.