GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-525W
VS
The verdict
54GDF-525W leads on the differences that matter
The largest is module efficiency: 0.83 pp more efficient. 10 of 19 comparable parameters are identical.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
9 of 19 parameters
What actually differs
Parameter
48GDF-455W
54GDF-525W
Difference
Module efficiency
22.77 %
23.60 %
0.83 pp more efficient
Rated power
455 Wp
525 Wp
70 W more power
Power density
227.7 Wp/m²
236.0 Wp/m²
8.2 Wp/m² higher
Weight
24.5 kg
27.3 kg
2.8 kg lighter
Open-circuit voltage
35.30 V
40.30 V
5.00 V apart
Module area
1.998 m²
2.225 m²
0.227 m² apart
Voltage at max power
29.94 V
34.20 V
4.26 V apart
Cell count
96
108
12 cells apart
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
48GDF-455W
15,266 kWh
54GDF-525W
17,615 kWh
Lifetime gap
2,349 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
48GDF-455W
54GDF-525W
Standard test conditions
25 °C
100.0% of rated power
455 W
525 W
Cool, bright day
40 °C
95.7% of rated power
435 W
502 W
Typical summer roof
55 °C
91.3% of rated power
415 W
479 W
Hot roof
70 °C
87.0% of rated power
396 W
456 W
03
Full specification
Parameter
48GDF-455W
54GDF-525W
Difference
Power and efficiency
Rated power
455 Wp
525 Wp
+70 W for 54GDF-525W
Module efficiency
22.77 %
23.60 %
+0.83 pp for 54GDF-525W
Power density
227.7 Wp/m²
236.0 Wp/m²
+8.2 Wp/m² for 54GDF-525W
Open-circuit voltage
35.30 V
40.30 V
5.00 V apart
Voltage at max power
29.94 V
34.20 V
4.26 V apart
Short-circuit current
16.00 A
16.16 A
Effectively the same
Current at max power
15.20 A
15.35 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
Module area
1.998 m²
2.225 m²
0.227 m² apart
Weight
24.5 kg
27.3 kg
-2.8 kg for 48GDF-455W
Weight per kWp
53.8 kg/kWp
52.0 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
108
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#3,073
vs
#627
54GDF-525W leads by 2,446 places
Power density
#2,888
vs
#653
54GDF-525W leads by 2,235 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#7,897
vs
#5,417
54GDF-525W leads by 2,480 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#8,644
vs
#5,035
54GDF-525W leads by 3,609 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-530
10 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-525
9 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-520
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-515W
10 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/48GDF-455W or GCL NT12R/54GDF-525W?
According to our database: GCL NT12R/54GDF-525 W has higher module efficiency (23.60% vs 22.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/48GDF-455W and GCL NT12R/54GDF-525W?
GCL NT12R/48GDF-455 W has a module efficiency of 22.77%, while GCL NT12R/54GDF-525 W is 23.60%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/48GDF-455W use vs GCL NT12R/54GDF-525W?
GCL NT12R/48GDF-455 W uses TOPCon cells; GCL NT12R/54GDF-525 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/48GDF-455W and GCL NT12R/54GDF-525W?
GCL NT12R/48GDF-455 W has a 30 years power warranty; GCL NT12R/54GDF-525 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/48GDF-455W and GCL NT12R/54GDF-525W bifacial panels?
Both GCL NT12R/48GDF-455 W and GCL NT12R/54GDF-525 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.