Skip to main content
48GDF-455W vs 54GDF-520W 10 of 19 identical Swap Change panels

GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-520W

NT12R/48GDF-455W
455 Wp 22.77 % TOPCon Bifacial
VS
NT12R/54GDF-520W
520 Wp 23.37 % TOPCon Bifacial
The verdict

54GDF-520W leads on the differences that matter

The largest is rated power: 65 W more power. 10 of 19 comparable parameters are identical.

See all 9 differences
How alike are they
10 of 19 comparable
parameters are identical
identical differs
01

What actually differs

9 of 19 parameters
Parameter 48GDF-455W 54GDF-520W Difference
Rated power 455 Wp 520 Wp 65 W more power
Module efficiency 22.77 % 23.37 % 0.60 pp more efficient
Weight 24.5 kg 27.3 kg 2.8 kg lighter
Power density 227.7 Wp/m² 233.7 Wp/m² 6.0 Wp/m² higher
Open-circuit voltage 35.30 V 40.05 V 4.75 V apart
Module area 1.998 m² 2.225 m² 0.227 m² apart
Voltage at max power 29.94 V 33.99 V 4.05 V apart
Cell count 96 108 12 cells apart
Dimensions 1762x1134x30 mm 1962x1134x30 mm 1762x1134x30 mm vs 1962x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
48GDF-455W
15,266 kWh
54GDF-520W
17,447 kWh
Lifetime gap
2,181 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 48GDF-455W 54GDF-520W
Standard test conditions 25 °C 100.0% of rated power 455 W 520 W
Cool, bright day 40 °C 95.7% of rated power 435 W 497 W
Typical summer roof 55 °C 91.3% of rated power 415 W 475 W
Hot roof 70 °C 87.0% of rated power 396 W 452 W
03

Full specification

Parameter 48GDF-455W 54GDF-520W Difference
Power and efficiency
Rated power 455 Wp 520 Wp +65 W for 54GDF-520W
Module efficiency 22.77 % 23.37 % +0.60 pp for 54GDF-520W
Power density 227.7 Wp/m² 233.7 Wp/m² +6.0 Wp/m² for 54GDF-520W
Open-circuit voltage 35.30 V 40.05 V 4.75 V apart
Voltage at max power 29.94 V 33.99 V 4.05 V apart
Short-circuit current 16.00 A 16.11 A Effectively the same
Current at max power 15.20 A 15.30 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1962x1134x30 mm 1762x1134x30 mm vs 1962x1134x30 mm
Module area 1.998 m² 2.225 m² 0.227 m² apart
Weight 24.5 kg 27.3 kg -2.8 kg for 48GDF-455W
Weight per kWp 53.8 kg/kWp 52.5 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 108 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#3,073 vs #930
54GDF-520W leads by 2,143 places
Power density
#2,888 vs #919
54GDF-520W leads by 1,969 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#7,897 vs #6,043
54GDF-520W leads by 1,854 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,644 vs #5,503
54GDF-520W leads by 3,141 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-530
10 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-525W
9 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-525
9 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-520
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-515W
10 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL NT12R/48GDF-455W or GCL NT12R/54GDF-520W?
According to our database: GCL NT12R/54GDF-520 W has higher module efficiency (23.37% vs 22.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/48GDF-455W and GCL NT12R/54GDF-520W?
GCL NT12R/48GDF-455 W has a module efficiency of 22.77%, while GCL NT12R/54GDF-520 W is 23.37%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/48GDF-455W use vs GCL NT12R/54GDF-520W?
GCL NT12R/48GDF-455 W uses TOPCon cells; GCL NT12R/54GDF-520 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/48GDF-455W and GCL NT12R/54GDF-520W?
GCL NT12R/48GDF-455 W has a 30 years power warranty; GCL NT12R/54GDF-520 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/48GDF-455W and GCL NT12R/54GDF-520W bifacial panels?
Both GCL NT12R/48GDF-455 W and GCL NT12R/54GDF-520 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 5 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.