GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-520
VS
The verdict
GCL-NT12R/54GDF-520 leads on the differences that matter
The largest is rated power: 65 W more power. 10 of 19 comparable parameters are identical.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
9 of 19 parameters
What actually differs
Parameter
NT12R/48GDF-455W
GCL-NT12R/54GDF-520
Difference
Rated power
455 Wp
520 Wp
65 W more power
Module efficiency
22.77 %
23.37 %
0.60 pp more efficient
Weight
24.5 kg
27.3 kg
2.8 kg lighter
Power density
227.7 Wp/m²
233.7 Wp/m²
6.0 Wp/m² higher
Open-circuit voltage
35.30 V
40.05 V
4.75 V apart
Module area
1.998 m²
2.225 m²
0.227 m² apart
Voltage at max power
29.94 V
33.99 V
4.05 V apart
Cell count
96
108
12 cells apart
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
NT12R/48GDF-455W
15,266 kWh
GCL-NT12R/54GDF-520
17,447 kWh
Lifetime gap
2,181 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
NT12R/48GDF-455W
GCL-NT12R/54GDF-520
Standard test conditions
25 °C
100.0% of rated power
455 W
520 W
Cool, bright day
40 °C
95.7% of rated power
435 W
497 W
Typical summer roof
55 °C
91.3% of rated power
415 W
475 W
Hot roof
70 °C
87.0% of rated power
396 W
452 W
03
Full specification
Parameter
NT12R/48GDF-455W
GCL-NT12R/54GDF-520
Difference
Power and efficiency
Rated power
455 Wp
520 Wp
+65 W for GCL-NT12R/54GDF-520
Module efficiency
22.77 %
23.37 %
+0.60 pp for GCL-NT12R/54GDF-520
Power density
227.7 Wp/m²
233.7 Wp/m²
+6.0 Wp/m² for GCL-NT12R/54GDF-520
Open-circuit voltage
35.30 V
40.05 V
4.75 V apart
Voltage at max power
29.94 V
33.99 V
4.05 V apart
Short-circuit current
16.00 A
16.11 A
Effectively the same
Current at max power
15.20 A
15.30 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
Module area
1.998 m²
2.225 m²
0.227 m² apart
Weight
24.5 kg
27.3 kg
-2.8 kg for NT12R/48GDF-455W
Weight per kWp
53.8 kg/kWp
52.5 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
108
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#3,073
vs
#930
GCL-NT12R/54GDF-520 leads by 2,143 places
Power density
#2,888
vs
#919
GCL-NT12R/54GDF-520 leads by 1,969 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#7,897
vs
#6,043
GCL-NT12R/54GDF-520 leads by 1,854 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#8,644
vs
#5,503
GCL-NT12R/54GDF-520 leads by 3,141 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-530
10 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-525W
9 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL GCL-NT12R/54GDF-525
9 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54GDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL NT12R/48GDF-455W vs GCL NT12R/54BGDF-515W
10 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/48GDF-455W or GCL GCL-NT12R/54GDF-520?
According to our database: GCL GCL-NT12R/54GDF-520 has higher module efficiency (23.37% vs 22.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/48GDF-455W and GCL GCL-NT12R/54GDF-520?
GCL NT12R/48GDF-455 W has a module efficiency of 22.77%, while GCL GCL-NT12R/54GDF-520 is 23.37%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/48GDF-455W use vs GCL GCL-NT12R/54GDF-520?
GCL NT12R/48GDF-455 W uses TOPCon cells; GCL GCL-NT12R/54GDF-520 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/48GDF-455W and GCL GCL-NT12R/54GDF-520?
GCL NT12R/48GDF-455 W has a 30 years power warranty; GCL GCL-NT12R/54GDF-520 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/48GDF-455W and GCL GCL-NT12R/54GDF-520 bifacial panels?
Both GCL NT12R/48GDF-455 W and GCL GCL-NT12R/54GDF-520 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.