Skip to main content
NT10/78GDF-650W vs GCL-NT10/78GDF-645 19 of 19 identical Swap Change panels

GCL NT10/78GDF-650W vs GCL GCL-NT10/78GDF-645

NT10/78GDF-650W
650 Wp 23.25 % TOPCon Bifacial
VS
GCL GCL-NT10/78GDF-645
GCL-NT10/78GDF-645
645 Wp 23.07 % TOPCon Bifacial
The verdict

Identical on every published parameter

All 19 comparable parameters agree. Two records this alike are usually one panel sold under two names, or two bins of the same production line - decide on price and on who you would rather buy from.

How alike are they
19 of 19 comparable
parameters are identical
identical differs
01

What actually differs

0 of 19 parameters

Every comparable parameter agrees. The full specification is below.

02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
NT10/78GDF-650W
21,809 kWh
GCL-NT10/78GDF-645
21,641 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario NT10/78GDF-650W GCL-NT10/78GDF-645
Standard test conditions 25 °C 100.0% of rated power 650 W 645 W
Cool, bright day 40 °C 95.7% of rated power 622 W 617 W
Typical summer roof 55 °C 91.3% of rated power 593 W 589 W
Hot roof 70 °C 87.0% of rated power 565 W 561 W
03

Full specification

Parameter NT10/78GDF-650W GCL-NT10/78GDF-645 Difference
Power and efficiency
Rated power 650 Wp 645 Wp Effectively the same
Module efficiency 23.25 % 23.07 % Effectively the same
Power density 232.5 Wp/m² 230.7 Wp/m² Effectively the same
Open-circuit voltage 57.45 V 57.30 V Effectively the same
Voltage at max power 49.06 V 48.87 V Effectively the same
Short-circuit current 14.00 A 13.95 A Effectively the same
Current at max power 13.25 A 13.20 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2465x1134x30 mm 2465x1134x30 mm Same
Module area 2.795 m² 2.795 m² Same
Weight 33.6 kg 33.6 kg Same
Weight per kWp 51.7 kg/kWp 52.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 156 156 Same
Bifacial Yes Yes Same
04

Against the whole database

14,843 panels
Efficiency
#1,568 vs #2,055
NT10/78GDF-650W leads by 487 places
Power density
#1,546 vs #2,020
NT10/78GDF-650W leads by 474 places
Heat behaviour
#2,527 vs #2,527
Tied - the same position in the database
Weight
#5,445 vs #5,941
NT10/78GDF-650W leads by 496 places
Warranty
#32 vs #32
Tied - the same position in the database
Overall
#1,788 vs #1,999
NT10/78GDF-650W leads by 211 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL NT10/78GDF-650W vs GCL GCL-NT10/78GDF-665
3 differences, the largest is module efficiency
Same series, other bin
GCL NT10/78GDF-650W vs GCL GCL-NT10/78GDF-660
3 differences, the largest is module efficiency
Same series, other bin
GCL NT10/78GDF-650W vs GCL GCL-NT10/78GDF-655
The same specification on paper
Same series, other bin
GCL NT10/78GDF-650W vs GCL NT10/78GDF-655W
The same specification on paper
Same series, other bin
GCL NT10/78GDF-650W vs GCL GCL-NT10/78GDF-650
The same specification on paper
Same series, other bin
GCL NT10/78GDF-650W vs GCL NT10/78GDF-645W
The same specification on paper
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL NT10/78GDF-650W or GCL GCL-NT10/78GDF-645?
According to our database: GCL NT10/78GDF-650 W has higher module efficiency (23.25% vs 23.07%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT10/78GDF-650W and GCL GCL-NT10/78GDF-645?
GCL NT10/78GDF-650 W has a module efficiency of 23.25%, while GCL GCL-NT10/78GDF-645 is 23.07%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT10/78GDF-650W use vs GCL GCL-NT10/78GDF-645?
GCL NT10/78GDF-650 W uses TOPCon cells; GCL GCL-NT10/78GDF-645 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT10/78GDF-650W and GCL GCL-NT10/78GDF-645?
GCL NT10/78GDF-650 W has a 30 years power warranty; GCL GCL-NT10/78GDF-645 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT10/78GDF-650W and GCL GCL-NT10/78GDF-645 bifacial panels?
Both GCL NT10/78GDF-650 W and GCL GCL-NT10/78GDF-645 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 3 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.