GCL GCL-NT12R/54GDF-530 vs GCL GCL-NT12R/48GDF
VS
The verdict
54GDF-530 leads on the differences that matter
The largest is rated power: 55 W more power. 12 of 19 comparable parameters are identical.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
7 of 19 parameters
What actually differs
Parameter
54GDF-530
48GDF
Difference
Rated power
530 Wp
475 Wp
55 W more power
Weight
27.3 kg
24.5 kg
2.8 kg lighter
Open-circuit voltage
40.55 V
36.30 V
4.25 V apart
Module area
2.225 m²
1.998 m²
0.227 m² apart
Cell count
108
96
12 cells apart
Voltage at max power
34.42 V
30.75 V
3.67 V apart
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
54GDF-530
17,783 kWh
48GDF
15,937 kWh
Lifetime gap
1,846 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
54GDF-530
48GDF
Standard test conditions
25 °C
100.0% of rated power
530 W
475 W
Cool, bright day
40 °C
95.7% of rated power
507 W
454 W
Typical summer roof
55 °C
91.3% of rated power
484 W
434 W
Hot roof
70 °C
87.0% of rated power
461 W
413 W
03
Full specification
Parameter
54GDF-530
48GDF
Difference
Power and efficiency
Rated power
530 Wp
475 Wp
+55 W for 54GDF-530
Module efficiency
23.82 %
23.77 %
Effectively the same
Power density
238.2 Wp/m²
237.7 Wp/m²
Effectively the same
Open-circuit voltage
40.55 V
36.30 V
4.25 V apart
Voltage at max power
34.42 V
30.75 V
3.67 V apart
Short-circuit current
16.21 A
16.23 A
Effectively the same
Current at max power
15.40 A
15.45 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
Module area
2.225 m²
1.998 m²
0.227 m² apart
Weight
27.3 kg
24.5 kg
-2.8 kg for 48GDF
Weight per kWp
51.5 kg/kWp
51.6 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
96
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#418
vs
#499
54GDF-530 leads by 81 places
Power density
#451
vs
#467
54GDF-530 leads by 16 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#4,879
vs
#4,954
54GDF-530 leads by 75 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#4,679
vs
#6,608
54GDF-530 leads by 1,929 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54GDF-525W
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL GCL-NT12R/54GDF-525
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54BGDF-520W
5 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54GDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL GCL-NT12R/54GDF-520
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54BGDF-515W
5 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL GCL-NT12R/54GDF-530 or GCL GCL-NT12R/48GDF?
According to our database: GCL GCL-NT12R/54GDF-530 has higher module efficiency (23.82% vs 23.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/54GDF-530 and GCL GCL-NT12R/48GDF?
GCL GCL-NT12R/54GDF-530 has a module efficiency of 23.82%, while GCL GCL-NT12R/48GDF is 23.77%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/54GDF-530 use vs GCL GCL-NT12R/48GDF?
GCL GCL-NT12R/54GDF-530 uses TOPCon cells; GCL GCL-NT12R/48GDF uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/54GDF-530 and GCL GCL-NT12R/48GDF?
GCL GCL-NT12R/54GDF-530 has a 30 years power warranty; GCL GCL-NT12R/48GDF has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/54GDF-530 and GCL GCL-NT12R/48GDF bifacial panels?
Both GCL GCL-NT12R/54GDF-530 and GCL GCL-NT12R/48GDF are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.