Skip to main content
525 vs 530 18 of 19 identical Swap Change panels

GCL GCL-NT12R/54GDF-525 vs GCL GCL-NT12R/54GDF-530

GCL-NT12R/54GDF-525
525 Wp 23.60 % TOPCon Bifacial
VS
GCL-NT12R/54GDF-530
530 Wp 23.82 % TOPCon Bifacial
The verdict

530 leads on the differences that matter

The largest is module efficiency: 0.22 pp more efficient. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter 525 530 Difference
Module efficiency 23.60 % 23.82 % 0.22 pp more efficient
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
525
17,615 kWh
530
17,783 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 525 530
Standard test conditions 25 °C 100.0% of rated power 525 W 530 W
Cool, bright day 40 °C 95.7% of rated power 502 W 507 W
Typical summer roof 55 °C 91.3% of rated power 479 W 484 W
Hot roof 70 °C 87.0% of rated power 456 W 461 W
03

Full specification

Parameter 525 530 Difference
Power and efficiency
Rated power 525 Wp 530 Wp Effectively the same
Module efficiency 23.60 % 23.82 % +0.22 pp for 530
Power density 236.0 Wp/m² 238.2 Wp/m² Effectively the same
Open-circuit voltage 40.30 V 40.55 V Effectively the same
Voltage at max power 34.20 V 34.42 V Effectively the same
Short-circuit current 16.16 A 16.21 A Effectively the same
Current at max power 15.35 A 15.40 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1962x1134x30 mm 1962x1134x30 mm Same
Module area 2.225 m² 2.225 m² Same
Weight 27.3 kg 27.3 kg Same
Weight per kWp 52.0 kg/kWp 51.5 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#627 vs #418
530 leads by 209 places
Power density
#653 vs #451
530 leads by 202 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#5,417 vs #4,879
530 leads by 538 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#5,035 vs #4,679
530 leads by 356 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54GDF-525W
The same specification on paper
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54BGDF-520W
4 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54GDF-520W
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL GCL-NT12R/54GDF-520
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54BGDF-515W
5 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54GDF-515W
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NT12R/54GDF-525 or GCL GCL-NT12R/54GDF-530?
According to our database: GCL GCL-NT12R/54GDF-530 has higher module efficiency (23.82% vs 23.60%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/54GDF-525 and GCL GCL-NT12R/54GDF-530?
GCL GCL-NT12R/54GDF-525 has a module efficiency of 23.60%, while GCL GCL-NT12R/54GDF-530 is 23.82%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/54GDF-525 use vs GCL GCL-NT12R/54GDF-530?
GCL GCL-NT12R/54GDF-525 uses TOPCon cells; GCL GCL-NT12R/54GDF-530 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/54GDF-525 and GCL GCL-NT12R/54GDF-530?
GCL GCL-NT12R/54GDF-525 has a 30 years power warranty; GCL GCL-NT12R/54GDF-530 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/54GDF-525 and GCL GCL-NT12R/54GDF-530 bifacial panels?
Both GCL GCL-NT12R/54GDF-525 and GCL GCL-NT12R/54GDF-530 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 5 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.