Skip to main content
GCL-NT12R/48GDF vs NT12R/54BGDF-515W 8 of 19 identical Swap Change panels

GCL GCL-NT12R/48GDF vs GCL NT12R/54BGDF-515W

GCL-NT12R/48GDF
475 Wp 23.77 % TOPCon Bifacial
VS
NT12R/54BGDF-515W
515 Wp 23.15 % TOPCon Bifacial
The verdict

GCL-NT12R/48GDF leads on the differences that matter

The largest is rated power: 40 W more power. 8 of 19 comparable parameters are identical.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs
01

What actually differs

11 of 19 parameters
Parameter GCL-NT12R/48GDF NT12R/54BGDF-515W Difference
Rated power 475 Wp 515 Wp 40 W more power
Module efficiency 23.77 % 23.15 % 0.62 pp more efficient
Weight 24.5 kg 27.3 kg 2.8 kg lighter
Power density 237.7 Wp/m² 231.5 Wp/m² 6.3 Wp/m² higher
Open-circuit voltage 36.30 V 41.19 V 4.89 V apart
Module area 1.998 m² 2.225 m² 0.227 m² apart
Voltage at max power 30.75 V 34.75 V 4.00 V apart
Cell count 96 108 12 cells apart
Short-circuit current 16.23 A 15.50 A 0.73 A apart
Dimensions 1762x1134x30 mm 1962x1134x30 mm 1762x1134x30 mm vs 1962x1134x30 mm
Current at max power 15.45 A 14.82 A 0.63 A apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
GCL-NT12R/48GDF
15,937 kWh
NT12R/54BGDF-515W
17,279 kWh
Lifetime gap
1,342 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario GCL-NT12R/48GDF NT12R/54BGDF-515W
Standard test conditions 25 °C 100.0% of rated power 475 W 515 W
Cool, bright day 40 °C 95.7% of rated power 454 W 493 W
Typical summer roof 55 °C 91.3% of rated power 434 W 470 W
Hot roof 70 °C 87.0% of rated power 413 W 448 W
03

Full specification

Parameter GCL-NT12R/48GDF NT12R/54BGDF-515W Difference
Power and efficiency
Rated power 475 Wp 515 Wp +40 W for NT12R/54BGDF-515W
Module efficiency 23.77 % 23.15 % +0.62 pp for GCL-NT12R/48GDF
Power density 237.7 Wp/m² 231.5 Wp/m² +6.3 Wp/m² for GCL-NT12R/48GDF
Open-circuit voltage 36.30 V 41.19 V 4.89 V apart
Voltage at max power 30.75 V 34.75 V 4.00 V apart
Short-circuit current 16.23 A 15.50 A 0.73 A apart
Current at max power 15.45 A 14.82 A 0.63 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1962x1134x30 mm 1762x1134x30 mm vs 1962x1134x30 mm
Module area 1.998 m² 2.225 m² 0.227 m² apart
Weight 24.5 kg 27.3 kg -2.8 kg for GCL-NT12R/48GDF
Weight per kWp 51.6 kg/kWp 53.0 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 108 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#499 vs #1,503
GCL-NT12R/48GDF leads by 1,004 places
Power density
#467 vs #1,499
GCL-NT12R/48GDF leads by 1,032 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#4,954 vs #6,762
GCL-NT12R/48GDF leads by 1,808 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#6,608 vs #5,886
NT12R/54BGDF-515W leads by 722 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-530
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-525W
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-525
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54BGDF-520W
11 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-520
9 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NT12R/48GDF or GCL NT12R/54BGDF-515W?
According to our database: GCL GCL-NT12R/48GDF has higher module efficiency (23.77% vs 23.15%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W?
GCL GCL-NT12R/48GDF has a module efficiency of 23.77%, while GCL NT12R/54BGDF-515 W is 23.15%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/48GDF use vs GCL NT12R/54BGDF-515W?
GCL GCL-NT12R/48GDF uses TOPCon cells; GCL NT12R/54BGDF-515 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W?
GCL GCL-NT12R/48GDF has a 30 years power warranty; GCL NT12R/54BGDF-515 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W bifacial panels?
Both GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.