GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/48BGDF-435
VS
The verdict
48GDF leads on the differences that matter
The largest is module efficiency: 2.00 pp more efficient. 10 of 19 comparable parameters are identical.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
9 of 19 parameters
What actually differs
Parameter
48GDF
48BGDF-435
Difference
Module efficiency
23.77 %
21.77 %
2.00 pp more efficient
Rated power
475 Wp
435 Wp
40 W more power
Power density
237.7 Wp/m²
217.7 Wp/m²
20.0 Wp/m² higher
Weight
24.5 kg
21.5 kg
3.0 kg lighter
Weight per kWp
51.6 kg/kWp
49.4 kg/kWp
2.2 kg/kWp lighter
Short-circuit current
16.23 A
15.46 A
0.77 A apart
Open-circuit voltage
36.30 V
35.08 V
1.22 V apart
Current at max power
15.45 A
14.72 A
0.73 A apart
Voltage at max power
30.75 V
29.55 V
1.20 V apart
02
What it means on a roof
Thirty years of production
Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
48GDF
15,937 kWh
48BGDF-435
14,595 kWh
Lifetime gap
1,342 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
48GDF
48BGDF-435
Standard test conditions
25 °C
100.0% of rated power
475 W
435 W
Cool, bright day
40 °C
95.7% of rated power
454 W
416 W
Typical summer roof
55 °C
91.3% of rated power
434 W
397 W
Hot roof
70 °C
87.0% of rated power
413 W
378 W
03
Full specification
Parameter
48GDF
48BGDF-435
Difference
Power and efficiency
Rated power
475 Wp
435 Wp
+40 W for 48GDF
Module efficiency
23.77 %
21.77 %
+2.00 pp for 48GDF
Power density
237.7 Wp/m²
217.7 Wp/m²
+20.0 Wp/m² for 48GDF
Open-circuit voltage
36.30 V
35.08 V
1.22 V apart
Voltage at max power
30.75 V
29.55 V
1.20 V apart
Short-circuit current
16.23 A
15.46 A
0.77 A apart
Current at max power
15.45 A
14.72 A
0.73 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
1762x1134x30 mm
Same
Module area
1.998 m²
1.998 m²
Same
Weight
24.5 kg
21.5 kg
-3.0 kg for 48BGDF-435
Weight per kWp
51.6 kg/kWp
49.4 kg/kWp
-2.2 kg/kWp for 48BGDF-435
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
96
Same
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#499
vs
#7,233
48GDF leads by 6,734 places
Power density
#467
vs
#7,066
48GDF leads by 6,599 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#4,954
vs
#2,936
48BGDF-435 leads by 2,018 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#6,608
vs
#10,072
48GDF leads by 3,464 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-530
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-525W
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-525
7 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54BGDF-520W
11 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-520W
9 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-520
9 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL GCL-NT12R/48GDF or GCL GCL-NT12R/48BGDF-435?
According to our database: GCL GCL-NT12R/48GDF has higher module efficiency (23.77% vs 21.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/48GDF and GCL GCL-NT12R/48BGDF-435?
GCL GCL-NT12R/48GDF has a module efficiency of 23.77%, while GCL GCL-NT12R/48BGDF-435 is 21.77%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/48GDF use vs GCL GCL-NT12R/48BGDF-435?
GCL GCL-NT12R/48GDF uses TOPCon cells; GCL GCL-NT12R/48BGDF-435 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/48GDF and GCL GCL-NT12R/48BGDF-435?
GCL GCL-NT12R/48GDF has a 30 years power warranty; GCL GCL-NT12R/48BGDF-435 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/48GDF and GCL GCL-NT12R/48BGDF-435 bifacial panels?
Both GCL GCL-NT12R/48GDF and GCL GCL-NT12R/48BGDF-435 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.