GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-510W
VS
The verdict
NT12R/54BGDF-510W leads on the differences that matter
The largest is module efficiency: 1.15 pp more efficient. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
GCL-NT12R/48BGDF-435
NT12R/54BGDF-510W
Difference
Module efficiency
21.77 %
22.92 %
1.15 pp more efficient
Rated power
435 Wp
510 Wp
75 W more power
Power density
217.7 Wp/m²
229.2 Wp/m²
11.5 Wp/m² higher
Weight
21.5 kg
27.3 kg
5.8 kg lighter
Open-circuit voltage
35.08 V
40.90 V
5.82 V apart
Module area
1.998 m²
2.225 m²
0.227 m² apart
Weight per kWp
49.4 kg/kWp
53.5 kg/kWp
4.1 kg/kWp lighter
Voltage at max power
29.55 V
34.49 V
4.94 V apart
Cell count
96
108
12 cells apart
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
02
What it means on a roof
Thirty years of production
Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
GCL-NT12R/48BGDF-435
14,595 kWh
NT12R/54BGDF-510W
17,112 kWh
Lifetime gap
2,517 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
GCL-NT12R/48BGDF-435
NT12R/54BGDF-510W
Standard test conditions
25 °C
100.0% of rated power
435 W
510 W
Cool, bright day
40 °C
95.7% of rated power
416 W
488 W
Typical summer roof
55 °C
91.3% of rated power
397 W
466 W
Hot roof
70 °C
87.0% of rated power
378 W
443 W
03
Full specification
Parameter
GCL-NT12R/48BGDF-435
NT12R/54BGDF-510W
Difference
Power and efficiency
Rated power
435 Wp
510 Wp
+75 W for NT12R/54BGDF-510W
Module efficiency
21.77 %
22.92 %
+1.15 pp for NT12R/54BGDF-510W
Power density
217.7 Wp/m²
229.2 Wp/m²
+11.5 Wp/m² for NT12R/54BGDF-510W
Open-circuit voltage
35.08 V
40.90 V
5.82 V apart
Voltage at max power
29.55 V
34.49 V
4.94 V apart
Short-circuit current
15.46 A
15.47 A
Effectively the same
Current at max power
14.72 A
14.79 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
1962x1134x30 mm
1762x1134x30 mm vs 1962x1134x30 mm
Module area
1.998 m²
2.225 m²
0.227 m² apart
Weight
21.5 kg
27.3 kg
-5.8 kg for GCL-NT12R/48BGDF-435
Weight per kWp
49.4 kg/kWp
53.5 kg/kWp
-4.1 kg/kWp for GCL-NT12R/48BGDF-435
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
108
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#7,233
vs
#2,350
NT12R/54BGDF-510W leads by 4,883 places
Power density
#7,066
vs
#2,369
NT12R/54BGDF-510W leads by 4,697 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#2,936
vs
#7,509
GCL-NT12R/48BGDF-435 leads by 4,573 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#10,072
vs
#6,391
NT12R/54BGDF-510W leads by 3,681 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-520W
10 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-515W
10 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-505W
10 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-500W
10 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL NT12R/54BGDF-495W
10 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48BGDF-435 vs GCL GCL-NT12R/48GDF
9 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL GCL-NT12R/48BGDF-435 or GCL NT12R/54BGDF-510W?
According to our database: GCL NT12R/54BGDF-510 W has higher module efficiency (22.92% vs 21.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/48BGDF-435 and GCL NT12R/54BGDF-510W?
GCL GCL-NT12R/48BGDF-435 has a module efficiency of 21.77%, while GCL NT12R/54BGDF-510 W is 22.92%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/48BGDF-435 use vs GCL NT12R/54BGDF-510W?
GCL GCL-NT12R/48BGDF-435 uses TOPCon cells; GCL NT12R/54BGDF-510 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/48BGDF-435 and GCL NT12R/54BGDF-510W?
GCL GCL-NT12R/48BGDF-435 has a 30 years power warranty; GCL NT12R/54BGDF-510 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/48BGDF-435 and GCL NT12R/54BGDF-510W bifacial panels?
Both GCL GCL-NT12R/48BGDF-435 and GCL NT12R/54BGDF-510 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.