Skip to main content
NR10R/54BGDF vs NT12/66GDF-740 4 of 19 identical Swap Change panels

GCL GCL-NR10R/54BGDF vs GCL GCL-NT12/66GDF-740

GCL-NR10R/54BGDF
500 Wp 24.50 % TOPCon Bifacial
VS
GCL GCL-NT12/66GDF-740
GCL-NT12/66GDF-740
740 Wp 23.82 % TOPCon Bifacial
The verdict

NR10R/54BGDF leads on the differences that matter

The largest is module efficiency: 0.68 pp more efficient. 4 of 19 comparable parameters are identical.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs
01

What actually differs

15 of 19 parameters
Parameter NR10R/54BGDF NT12/66GDF-740 Difference
Module efficiency 24.50 % 23.82 % 0.68 pp more efficient
Rated power 500 Wp 740 Wp 240 W more power
Temperature coefficient -0.260 %/°C -0.290 %/°C 0.030 %/°C better in heat
Weight 24.6 kg 38.2 kg 13.6 kg lighter
Product warranty 30 yrs 12 yrs 18 yrs longer
Power density 245.0 Wp/m² 238.2 Wp/m² 6.7 Wp/m² higher
Open-circuit voltage 40.87 V 49.46 V 8.59 V apart
Short-circuit current 15.26 A 18.72 A 3.46 A apart
Module area 2.041 m² 3.106 m² 1.065 m² apart
Annual degradation 0.35 %/yr 0.40 %/yr 0.05 %/yr slower
Voltage at max power 34.71 V 41.60 V 6.89 V apart
Current at max power 14.41 A 17.79 A 3.38 A apart
Cell count 108 132 24 cells apart
Weight per kWp 49.2 kg/kWp 51.6 kg/kWp 2.4 kg/kWp lighter
Dimensions 1800x1134x30 mm 2384x1303x33 mm 1800x1134x30 mm vs 2384x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
NR10R/54BGDF
16,907 kWh
NT12/66GDF-740
24,828 kWh
Lifetime gap
7,921 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario NR10R/54BGDF NT12/66GDF-740
Standard test conditions 25 °C 100.0% of rated power 500 W 740 W
Cool, bright day 40 °C 95.7% of rated power 481 W 708 W
Typical summer roof 55 °C 91.3% of rated power 461 W 676 W
Hot roof 70 °C 87.0% of rated power 442 W 643 W
03

Full specification

Parameter NR10R/54BGDF NT12/66GDF-740 Difference
Power and efficiency
Rated power 500 Wp 740 Wp +240 W for NT12/66GDF-740
Module efficiency 24.50 % 23.82 % +0.68 pp for NR10R/54BGDF
Power density 245.0 Wp/m² 238.2 Wp/m² +6.7 Wp/m² for NR10R/54BGDF
Open-circuit voltage 40.87 V 49.46 V 8.59 V apart
Voltage at max power 34.71 V 41.60 V 6.89 V apart
Short-circuit current 15.26 A 18.72 A 3.46 A apart
Current at max power 14.41 A 17.79 A 3.38 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.290 %/°C +0.030 %/°C for NR10R/54BGDF
Mechanical
Dimensions 1800x1134x30 mm 2384x1303x33 mm 1800x1134x30 mm vs 2384x1303x33 mm
Module area 2.041 m² 3.106 m² 1.065 m² apart
Weight 24.6 kg 38.2 kg -13.6 kg for NR10R/54BGDF
Weight per kWp 49.2 kg/kWp 51.6 kg/kWp -2.4 kg/kWp for NR10R/54BGDF
Warranty and degradation
Product warranty 30 yrs 12 yrs +18 yrs for NR10R/54BGDF
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr 0.40 %/yr -0.05 %/yr for NR10R/54BGDF
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 132 24 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#102 vs #499
NR10R/54BGDF leads by 397 places
Power density
#105 vs #513
NR10R/54BGDF leads by 408 places
Heat behaviour
#521 vs #2,288
NR10R/54BGDF leads by 1,767 places
Weight
#2,825 vs #5,088
NR10R/54BGDF leads by 2,263 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#1,686 vs #194
NT12/66GDF-740 leads by 1,492 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL GCL-NT12/66GDF-735
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL GCL-NT12/66GDF-730
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL NT12/66GDF-730
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL GCL-NT12/66GDF-725
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL NT12/66GDF-725
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-740 vs GCL GCL-NT12/66GDF 725
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NR10R/54BGDF or GCL GCL-NT12/66GDF-740?
According to our database: GCL GCL-NR10R/54BGDF has higher module efficiency (24.50% vs 23.82%); GCL GCL-NR10R/54BGDF tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NR10R/54BGDF and GCL GCL-NT12/66GDF-740?
GCL GCL-NR10R/54BGDF has a module efficiency of 24.50%, while GCL GCL-NT12/66GDF-740 is 23.82%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NR10R/54BGDF use vs GCL GCL-NT12/66GDF-740?
GCL GCL-NR10R/54BGDF uses TOPCon cells; GCL GCL-NT12/66GDF-740 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NR10R/54BGDF and GCL GCL-NT12/66GDF-740?
GCL GCL-NR10R/54BGDF has a 30 years power warranty; GCL GCL-NT12/66GDF-740 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NR10R/54BGDF and GCL GCL-NT12/66GDF-740 bifacial panels?
Both GCL GCL-NR10R/54BGDF and GCL GCL-NT12/66GDF-740 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 3 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.