GCL GCL-M10/72GDF-B-545 vs GCL GCL-NT12/66GDF-735
VS
The verdict
NT12/66GDF-735 leads on the differences that matter
The largest is module efficiency: 2.86 pp more efficient. 6 of 19 comparable parameters are identical.
See all 13 differencesHow alike are they
6
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
13 of 19 parameters
What actually differs
Parameter
M10/72GDF-B-545
NT12/66GDF-735
Difference
Module efficiency
20.80 %
23.66 %
2.86 pp more efficient
Temperature coefficient
-0.350 %/°C
-0.290 %/°C
0.060 %/°C better in heat
Rated power
545 Wp
735 Wp
190 W more power
Power density
207.7 Wp/m²
236.6 Wp/m²
28.9 Wp/m² higher
Weight
33.2 kg
38.2 kg
5.0 kg lighter
Weight per kWp
60.9 kg/kWp
52.0 kg/kWp
8.9 kg/kWp lighter
Short-circuit current
13.83 A
18.68 A
4.85 A apart
Module area
2.624 m²
3.106 m²
0.482 m² apart
Cell technology
PERC
TOPCon
PERC vs TOPCon
Current at max power
13.07 A
17.75 A
4.68 A apart
Cell count
144
132
12 cells apart
Annual degradation
0.45 %/yr
0.40 %/yr
0.05 %/yr slower
Dimensions
2290x1146x30 mm
2384x1303x33 mm
2290x1146x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
M10/72GDF-B-545
17,947 kWh
NT12/66GDF-735
24,661 kWh
Lifetime gap
6,714 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
M10/72GDF-B-545
NT12/66GDF-735
Standard test conditions
25 °C
100.0% of rated power
545 W
735 W
Cool, bright day
40 °C
94.8% of rated power
516 W
703 W
Typical summer roof
55 °C
89.5% of rated power
488 W
671 W
Hot roof
70 °C
84.2% of rated power
459 W
639 W
03
Full specification
Parameter
M10/72GDF-B-545
NT12/66GDF-735
Difference
Power and efficiency
Rated power
545 Wp
735 Wp
+190 W for NT12/66GDF-735
Module efficiency
20.80 %
23.66 %
+2.86 pp for NT12/66GDF-735
Power density
207.7 Wp/m²
236.6 Wp/m²
+28.9 Wp/m² for NT12/66GDF-735
Open-circuit voltage
49.52 V
49.24 V
Effectively the same
Voltage at max power
41.70 V
41.41 V
Effectively the same
Short-circuit current
13.83 A
18.68 A
4.85 A apart
Current at max power
13.07 A
17.75 A
4.68 A apart
Temperature
Temperature coefficient
-0.350 %/°C
-0.290 %/°C
+0.060 %/°C for NT12/66GDF-735
Mechanical
Dimensions
2290x1146x30 mm
2384x1303x33 mm
2290x1146x30 mm vs 2384x1303x33 mm
Module area
2.624 m²
3.106 m²
0.482 m² apart
Weight
33.2 kg
38.2 kg
-5.0 kg for M10/72GDF-B-545
Weight per kWp
60.9 kg/kWp
52.0 kg/kWp
-8.9 kg/kWp for NT12/66GDF-735
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.45 %/yr
0.40 %/yr
-0.05 %/yr for NT12/66GDF-735
Technology
Cell technology
PERC
TOPCon
PERC vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
132
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#10,457
vs
#602
NT12/66GDF-735 leads by 9,855 places
Power density
#10,552
vs
#582
NT12/66GDF-735 leads by 9,970 places
Heat behaviour
#10,419
vs
#2,165
NT12/66GDF-735 leads by 8,254 places
Weight
#12,552
vs
#5,413
NT12/66GDF-735 leads by 7,139 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#7,858
vs
#244
NT12/66GDF-735 leads by 7,614 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL GCL-M10/72GDF-B-545 vs GCL GCL-M10/72GDF-B-555
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-M10/72GDF-B-545 vs GCL GCL-M10/72GDF-B-550
One difference: module efficiency
Same series, other bin
GCL GCL-M10/72GDF-B-545 vs GCL GCL-M10/72GDF-B-540
One difference: module efficiency
Same series, other bin
GCL GCL-M10/72GDF-B-545 vs GCL GCL-M10/72GDF-B-535
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-735 vs GCL GCL-NT12/66GDF-740
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-735 vs GCL GCL-NT12/66GDF-730
The same specification on paper
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL GCL-M10/72GDF-B-545 or GCL GCL-NT12/66GDF-735?
According to our database: GCL GCL-NT12/66GDF-735 has higher module efficiency (23.66% vs 20.80%); GCL GCL-NT12/66GDF-735 tolerates heat better (temp coeff -0.290%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-M10/72GDF-B-545 and GCL GCL-NT12/66GDF-735?
GCL GCL-M10/72GDF-B-545 has a module efficiency of 20.80%, while GCL GCL-NT12/66GDF-735 is 23.66%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-M10/72GDF-B-545 use vs GCL GCL-NT12/66GDF-735?
GCL GCL-M10/72GDF-B-545 uses PERC cells; GCL GCL-NT12/66GDF-735 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-M10/72GDF-B-545 and GCL GCL-NT12/66GDF-735?
GCL GCL-M10/72GDF-B-545 has a 30 years power warranty; GCL GCL-NT12/66GDF-735 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-M10/72GDF-B-545 and GCL GCL-NT12/66GDF-735 bifacial panels?
Both GCL GCL-M10/72GDF-B-545 and GCL GCL-NT12/66GDF-735 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.