FuturaSun FU 720 MV vs FuturaSun FU 450 M Silk Rhino All Black
VS
The verdict
720 MV leads on the differences that matter
The largest is module efficiency: 0.66 pp more efficient. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
720 MV
450 M Silk Rhino All Black
Difference
Module efficiency
23.18 %
22.52 %
0.66 pp more efficient
Rated power
720 Wp
450 Wp
270 W more power
Performance warranty
30 yrs
25 yrs
5 yrs longer
Weight
38.2 kg
26.6 kg
11.6 kg lighter
Weight per kWp
53.1 kg/kWp
59.1 kg/kWp
6.1 kg/kWp lighter
Power density
231.8 Wp/m²
225.2 Wp/m²
6.6 Wp/m² higher
Open-circuit voltage
49.05 V
35.47 V
13.58 V apart
Short-circuit current
18.54 A
15.97 A
2.57 A apart
Module area
3.106 m²
1.998 m²
1.108 m² apart
Cell technology
TOPCon
N-type
TOPCon vs N-type
Voltage at max power
41.27 V
30.01 V
11.26 V apart
Current at max power
17.45 A
15.00 A
2.45 A apart
Cell count
132
96
36 cells apart
Bifacial
Yes
No
Yes vs No
Dimensions
2384x1303x33 mm
1762x1134x30 mm
2384x1303x33 mm vs 1762x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
720 MV
24,157 kWh
450 M Silk Rhino All Black
15,098 kWh
Lifetime gap
9,059 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
720 MV
450 M Silk Rhino All Black
Standard test conditions
25 °C
100.0% of rated power
720 W
450 W
Cool, bright day
40 °C
95.7% of rated power
689 W
430 W
Typical summer roof
55 °C
91.3% of rated power
657 W
411 W
Hot roof
70 °C
87.0% of rated power
626 W
391 W
03
Full specification
Parameter
720 MV
450 M Silk Rhino All Black
Difference
Power and efficiency
Rated power
720 Wp
450 Wp
+270 W for 720 MV
Module efficiency
23.18 %
22.52 %
+0.66 pp for 720 MV
Power density
231.8 Wp/m²
225.2 Wp/m²
+6.6 Wp/m² for 720 MV
Open-circuit voltage
49.05 V
35.47 V
13.58 V apart
Voltage at max power
41.27 V
30.01 V
11.26 V apart
Short-circuit current
18.54 A
15.97 A
2.57 A apart
Current at max power
17.45 A
15.00 A
2.45 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2384x1303x33 mm
1762x1134x30 mm
2384x1303x33 mm vs 1762x1134x30 mm
Module area
3.106 m²
1.998 m²
1.108 m² apart
Weight
38.2 kg
26.6 kg
-11.6 kg for 450 M Silk Rhino All Black
Weight per kWp
53.1 kg/kWp
59.1 kg/kWp
-6.1 kg/kWp for 720 MV
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
30 yrs
25 yrs
+5 yrs for 720 MV
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
N-type
TOPCon vs N-type
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
96
36 cells apart
Bifacial
Yes
No
Yes vs No
04
14,354 panels
Against the whole database
Efficiency
#1,539
vs
#4,277
720 MV leads by 2,738 places
Power density
#1,460
vs
#4,400
720 MV leads by 2,940 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#6,958
vs
#12,296
720 MV leads by 5,338 places
Warranty
#31
vs
#10,073
720 MV leads by 10,042 places
Overall
#375
vs
#9,721
720 MV leads by 9,346 places
05
Open the full database
More useful comparisons
Same series, other bin
FuturaSun
FuturaSun FU 720 MV vs FuturaSun FU 710 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 720 MV vs FuturaSun FU 700 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 450 M Silk Rhino All Black vs FuturaSun FU 445 M Silk Rhino All Black
One difference: module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 450 M Silk Rhino All Black vs FuturaSun FU 440 M Silk Rhino All Black
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 450 M Silk Rhino All Black vs FuturaSun FU 430 M Silk Rhino All Black
10 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 450 M Silk Rhino All Black vs FuturaSun FU 425 M Silk Rhino All Black
11 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: FuturaSun FU 720 MV or FuturaSun FU 450 M Silk Rhino All Black?
According to our database: FuturaSun FU 720 MV has higher module efficiency (23.18% vs 22.52%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 720 MV and FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU 720 MV has a module efficiency of 23.18%, while FuturaSun FU 450 M Silk Rhino All Black is 22.52%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 720 MV use vs FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU 720 MV uses TOPCon cells; FuturaSun FU 450 M Silk Rhino All Black uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 720 MV and FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU 720 MV has a 30 years power warranty; FuturaSun FU 450 M Silk Rhino All Black has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 720 MV and FuturaSun FU 450 M Silk Rhino All Black bifacial panels?
FuturaSun FU 720 MV is bifacial (captures light from both faces); FuturaSun FU 450 M Silk Rhino All Black is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 8 FuturaSun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.