Skip to main content
480 MVBF Silk Nova EU vs 720 MV 4 of 19 identical Swap Change panels

FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 720 MV

FuturaSun FU 480 MVBF Silk Nova EU
FuturaSun
FU 480 MVBF Silk Nova EU
480 Wp 22.17 % TOPCon
VS
FuturaSun
FU 720 MV
720 Wp 23.18 % TOPCon Bifacial
The verdict

720 MV leads on the differences that matter

The largest is module efficiency: 1.01 pp more efficient. 4 of 19 comparable parameters are identical.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs
01

What actually differs

15 of 19 parameters
Parameter 480 MVBF Silk Nova EU 720 MV Difference
Module efficiency 22.17 % 23.18 % 1.01 pp more efficient
Temperature coefficient -0.322 %/°C -0.290 %/°C 0.032 %/°C better in heat
Rated power 480 Wp 720 Wp 240 W more power
Performance warranty 25 yrs 30 yrs 5 yrs longer
Power density 221.7 Wp/m² 231.8 Wp/m² 10.1 Wp/m² higher
Weight 22.3 kg 38.2 kg 15.9 kg lighter
Weight per kWp 46.5 kg/kWp 53.1 kg/kWp 6.6 kg/kWp lighter
Open-circuit voltage 42.85 V 49.05 V 6.20 V apart
Short-circuit current 14.38 A 18.54 A 4.16 A apart
Module area 2.165 m² 3.106 m² 0.942 m² apart
Voltage at max power 35.10 V 41.27 V 6.17 V apart
Current at max power 13.68 A 17.45 A 3.77 A apart
Cell count 120 132 12 cells apart
Bifacial No Yes No vs Yes
Dimensions 1909x1134x35 mm 2384x1303x33 mm 1909x1134x35 mm vs 2384x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
480 MVBF Silk Nova EU
16,105 kWh
720 MV
24,157 kWh
Lifetime gap
8,052 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 480 MVBF Silk Nova EU 720 MV
Standard test conditions 25 °C 100.0% of rated power 480 W 720 W
Cool, bright day 40 °C 95.2% of rated power 457 W 689 W
Typical summer roof 55 °C 90.3% of rated power 434 W 657 W
Hot roof 70 °C 85.5% of rated power 410 W 626 W
03

Full specification

Parameter 480 MVBF Silk Nova EU 720 MV Difference
Power and efficiency
Rated power 480 Wp 720 Wp +240 W for 720 MV
Module efficiency 22.17 % 23.18 % +1.01 pp for 720 MV
Power density 221.7 Wp/m² 231.8 Wp/m² +10.1 Wp/m² for 720 MV
Open-circuit voltage 42.85 V 49.05 V 6.20 V apart
Voltage at max power 35.10 V 41.27 V 6.17 V apart
Short-circuit current 14.38 A 18.54 A 4.16 A apart
Current at max power 13.68 A 17.45 A 3.77 A apart
Temperature
Temperature coefficient -0.322 %/°C -0.290 %/°C +0.032 %/°C for 720 MV
Mechanical
Dimensions 1909x1134x35 mm 2384x1303x33 mm 1909x1134x35 mm vs 2384x1303x33 mm
Module area 2.165 m² 3.106 m² 0.942 m² apart
Weight 22.3 kg 38.2 kg -15.9 kg for 480 MVBF Silk Nova EU
Weight per kWp 46.5 kg/kWp 53.1 kg/kWp -6.6 kg/kWp for 480 MVBF Silk Nova EU
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 25 yrs 30 yrs +5 yrs for 720 MV
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 120 132 12 cells apart
Bifacial No Yes No vs Yes
04

Against the whole database

14,354 panels
Efficiency
#6,155 vs #1,539
720 MV leads by 4,616 places
Power density
#6,106 vs #1,460
720 MV leads by 4,646 places
Heat behaviour
#8,750 vs #2,288
720 MV leads by 6,462 places
Weight
#1,183 vs #6,958
480 MVBF Silk Nova EU leads by 5,775 places
Warranty
#10,073 vs #31
720 MV leads by 10,042 places
Overall
#8,953 vs #375
720 MV leads by 8,578 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 580 MV Silk Nova EU
10 differences, the largest is temperature coefficient
Same series, other bin
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 430 MV Silk Nova EU
9 differences, the largest is temperature coefficient
Same series, other bin
FuturaSun
FuturaSun FU 720 MV vs FuturaSun FU 710 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 720 MV vs FuturaSun FU 700 MV
3 differences, the largest is module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 645 MV Silk Nova RE Duetto
14 differences, the largest is module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 640 MV Silk Nova RE Duetto
14 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU 480 MVBF Silk Nova EU or FuturaSun FU 720 MV?
According to our database: FuturaSun FU 720 MV has higher module efficiency (23.18% vs 22.17%); FuturaSun FU 720 MV tolerates heat better (temp coeff -0.290%/°C vs -0.322%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 720 MV?
FuturaSun FU 480 MVBF Silk Nova EU has a module efficiency of 22.17%, while FuturaSun FU 720 MV is 23.18%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 480 MVBF Silk Nova EU use vs FuturaSun FU 720 MV?
FuturaSun FU 480 MVBF Silk Nova EU uses TOPCon cells; FuturaSun FU 720 MV uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 720 MV?
FuturaSun FU 480 MVBF Silk Nova EU has a 25 years power warranty; FuturaSun FU 720 MV has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 720 MV bifacial panels?
FuturaSun FU 720 MV is bifacial (captures light from both faces); FuturaSun FU 480 MVBF Silk Nova EU is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.