FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 700 MV
VS
The verdict
700 MV leads on the differences that matter
The largest is temperature coefficient: 0.032 %/°C better in heat. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
480 MVBF Silk Nova EU
700 MV
Difference
Temperature coefficient
-0.322 %/°C
-0.290 %/°C
0.032 %/°C better in heat
Rated power
480 Wp
700 Wp
220 W more power
Performance warranty
25 yrs
30 yrs
5 yrs longer
Weight
22.3 kg
38.2 kg
15.9 kg lighter
Weight per kWp
46.5 kg/kWp
54.6 kg/kWp
8.1 kg/kWp lighter
Module efficiency
22.17 %
22.53 %
0.36 pp more efficient
Open-circuit voltage
42.85 V
48.26 V
5.41 V apart
Short-circuit current
14.38 A
18.38 A
4.00 A apart
Module area
2.165 m²
3.106 m²
0.942 m² apart
Power density
221.7 Wp/m²
225.3 Wp/m²
3.6 Wp/m² higher
Voltage at max power
35.10 V
40.50 V
5.40 V apart
Current at max power
13.68 A
17.29 A
3.61 A apart
Cell count
120
132
12 cells apart
Bifacial
No
Yes
No vs Yes
Dimensions
1909x1134x35 mm
2384x1303x33 mm
1909x1134x35 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
480 MVBF Silk Nova EU
16,105 kWh
700 MV
23,486 kWh
Lifetime gap
7,381 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
480 MVBF Silk Nova EU
700 MV
Standard test conditions
25 °C
100.0% of rated power
480 W
700 W
Cool, bright day
40 °C
95.2% of rated power
457 W
670 W
Typical summer roof
55 °C
90.3% of rated power
434 W
639 W
Hot roof
70 °C
85.5% of rated power
410 W
609 W
03
Full specification
Parameter
480 MVBF Silk Nova EU
700 MV
Difference
Power and efficiency
Rated power
480 Wp
700 Wp
+220 W for 700 MV
Module efficiency
22.17 %
22.53 %
+0.36 pp for 700 MV
Power density
221.7 Wp/m²
225.3 Wp/m²
+3.6 Wp/m² for 700 MV
Open-circuit voltage
42.85 V
48.26 V
5.41 V apart
Voltage at max power
35.10 V
40.50 V
5.40 V apart
Short-circuit current
14.38 A
18.38 A
4.00 A apart
Current at max power
13.68 A
17.29 A
3.61 A apart
Temperature
Temperature coefficient
-0.322 %/°C
-0.290 %/°C
+0.032 %/°C for 700 MV
Mechanical
Dimensions
1909x1134x35 mm
2384x1303x33 mm
1909x1134x35 mm vs 2384x1303x33 mm
Module area
2.165 m²
3.106 m²
0.942 m² apart
Weight
22.3 kg
38.2 kg
-15.9 kg for 480 MVBF Silk Nova EU
Weight per kWp
46.5 kg/kWp
54.6 kg/kWp
-8.1 kg/kWp for 480 MVBF Silk Nova EU
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
25 yrs
30 yrs
+5 yrs for 700 MV
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
120
132
12 cells apart
Bifacial
No
Yes
No vs Yes
04
14,354 panels
Against the whole database
Efficiency
#6,155
vs
#4,151
700 MV leads by 2,004 places
Power density
#6,106
vs
#4,158
700 MV leads by 1,948 places
Heat behaviour
#8,750
vs
#2,288
700 MV leads by 6,462 places
Weight
#1,183
vs
#9,134
480 MVBF Silk Nova EU leads by 7,951 places
Warranty
#10,073
vs
#31
700 MV leads by 10,042 places
Overall
#8,953
vs
#953
700 MV leads by 8,000 places
05
Open the full database
More useful comparisons
Same series, other bin
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 580 MV Silk Nova EU
10 differences, the largest is temperature coefficient
Same series, other bin
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 430 MV Silk Nova EU
9 differences, the largest is temperature coefficient
Same series, other bin
FuturaSun
FuturaSun FU 700 MV vs FuturaSun FU 720 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 700 MV vs FuturaSun FU 710 MV
3 differences, the largest is module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 645 MV Silk Nova RE Duetto
14 differences, the largest is module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 480 MVBF Silk Nova EU vs FuturaSun FU 640 MV Silk Nova RE Duetto
14 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: FuturaSun FU 480 MVBF Silk Nova EU or FuturaSun FU 700 MV?
According to our database: FuturaSun FU 700 MV has higher module efficiency (22.53% vs 22.17%); FuturaSun FU 700 MV tolerates heat better (temp coeff -0.290%/°C vs -0.322%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 700 MV?
FuturaSun FU 480 MVBF Silk Nova EU has a module efficiency of 22.17%, while FuturaSun FU 700 MV is 22.53%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 480 MVBF Silk Nova EU use vs FuturaSun FU 700 MV?
FuturaSun FU 480 MVBF Silk Nova EU uses TOPCon cells; FuturaSun FU 700 MV uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 700 MV?
FuturaSun FU 480 MVBF Silk Nova EU has a 25 years power warranty; FuturaSun FU 700 MV has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 480 MVBF Silk Nova EU and FuturaSun FU 700 MV bifacial panels?
FuturaSun FU 700 MV is bifacial (captures light from both faces); FuturaSun FU 480 MVBF Silk Nova EU is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 8 FuturaSun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.