EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-565NT72-HLV

EGing PV
EG-550M72-HL/BF-DG 550W
550 Wp
21.29 %
PERC
Bifacial
Incomplete
VS
The verdict
565NT72-HLV leads on the differences that matter
The largest is temperature coefficient: 0.050 %/°C better in heat. 7 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 11 differencesHow alike are they
7
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 18 parameters
What actually differs
Parameter
550M72-HL/BF-DG 550W
565NT72-HLV
Difference
Temperature coefficient
-0.350 %/°C
-0.300 %/°C
0.050 %/°C better in heat
Performance warranty
30 yrs
25 yrs
5 yrs longer
Module efficiency
21.29 %
21.87 %
0.58 pp more efficient
Weight
31.7 kg
27.0 kg
4.7 kg lighter
Weight per kWp
57.6 kg/kWp
47.8 kg/kWp
9.8 kg/kWp lighter
Power density
212.9 Wp/m²
218.7 Wp/m²
5.8 Wp/m² higher
Rated power
550 Wp
565 Wp
15 W more power
Cell technology
PERC
TOPCon
PERC vs TOPCon
Bifacial
Yes
No
Yes vs No
Short-circuit current
13.68 A
14.25 A
0.57 A apart
Current at max power
12.93 A
13.46 A
0.53 A apart
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
550M72-HL/BF-DG 550W
18,454 kWh
565NT72-HLV
18,957 kWh
Lifetime gap
503 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
550M72-HL/BF-DG 550W
565NT72-HLV
Standard test conditions
25 °C
100.0% of rated power
550 W
565 W
Cool, bright day
40 °C
94.8% of rated power
521 W
540 W
Typical summer roof
55 °C
89.5% of rated power
492 W
514 W
Hot roof
70 °C
84.2% of rated power
463 W
489 W
03
Full specification
Parameter
550M72-HL/BF-DG 550W
565NT72-HLV
Difference
Power and efficiency
Rated power
550 Wp
565 Wp
+15 W for 565NT72-HLV
Module efficiency
21.29 %
21.87 %
+0.58 pp for 565NT72-HLV
Power density
212.9 Wp/m²
218.7 Wp/m²
+5.8 Wp/m² for 565NT72-HLV
Open-circuit voltage
50.34 V
50.85 V
Effectively the same
Voltage at max power
42.54 V
41.98 V
Effectively the same
Short-circuit current
13.68 A
14.25 A
0.57 A apart
Current at max power
12.93 A
13.46 A
0.53 A apart
Temperature
Temperature coefficient
-0.350 %/°C
-0.300 %/°C
+0.050 %/°C for 565NT72-HLV
Mechanical
Dimensions
2278x1134x30 mm
2278x1134x30 mm
Same
Module area
2.583 m²
2.583 m²
Same
Weight
31.7 kg
27.0 kg
-4.7 kg for 565NT72-HLV
Weight per kWp
57.6 kg/kWp
47.8 kg/kWp
-9.8 kg/kWp for 565NT72-HLV
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
25 yrs
+5 yrs for 550M72-HL/BF-DG 550W
Annual degradation
-
0.40 %/yr
Not published by EGing PV
Technology
Cell technology
PERC
TOPCon
PERC vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
144
Same
Bifacial
Yes
No
Yes vs No
04
14,354 panels
Against the whole database
Efficiency
#8,926
vs
#7,111
565NT72-HLV leads by 1,815 places
Power density
#8,711
vs
#7,044
565NT72-HLV leads by 1,667 places
Heat behaviour
#10,660
vs
#6,298
565NT72-HLV leads by 4,362 places
Weight
#11,580
vs
#1,921
565NT72-HLV leads by 9,659 places
Warranty
#31
vs
#10,073
550M72-HL/BF-DG 550W leads by 10,042 places
Overall
#7,154
vs
#6,837
565NT72-HLV leads by 317 places
05
Open the full database
More useful comparisons
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-580NT72-HLV
11 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-580NT72-HL/BF-DG
9 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-575NT72-HL/BF-DG
8 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-575NT72-HLV
11 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-570NT72-HL/BF-DG
8 differences, the largest is temperature coefficient
Same series, other bin
EGing PV
EGing PV EG-550M72-HL/BF-DG 550W vs EGing PV EG-570NT72-HLV
11 differences, the largest is temperature coefficient
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: EGing PV EG-550M72-HL/BF-DG 550W or EGing PV EG-565NT72-HLV?
According to our database: EGing PV EG-565NT72-HLV has higher module efficiency (21.87% vs 21.29%); EGing PV EG-565NT72-HLV tolerates heat better (temp coeff -0.300%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of EGing PV EG-550M72-HL/BF-DG 550W and EGing PV EG-565NT72-HLV?
EGing PV EG-550M72-HL/BF-DG 550 W has a module efficiency of 21.29%, while EGing PV EG-565NT72-HLV is 21.87%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does EGing PV EG-550M72-HL/BF-DG 550W use vs EGing PV EG-565NT72-HLV?
EGing PV EG-550M72-HL/BF-DG 550 W uses PERC cells; EGing PV EG-565NT72-HLV uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on EGing PV EG-550M72-HL/BF-DG 550W and EGing PV EG-565NT72-HLV?
EGing PV EG-550M72-HL/BF-DG 550 W has a 30 years power warranty; EGing PV EG-565NT72-HLV has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are EGing PV EG-550M72-HL/BF-DG 550W and EGing PV EG-565NT72-HLV bifacial panels?
EGing PV EG-550M72-HL/BF-DG 550 W is bifacial (captures light from both faces); EGing PV EG-565NT72-HLV is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 3 EGing PV offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.