Skip to main content
DH108ND-440W vs DH132NC-705 6 of 19 identical Swap Change panels

DAS Solar DAS-DH108ND-440W vs DAS Solar DAS-DH132NC-705

DAS Solar
DAS-DH108ND-440W
440 Wp 21.60 % TOPCon Bifacial
VS
DAS Solar
DAS-DH132NC-705
705 Wp 22.70 % TOPCon Bifacial
The verdict

DH132NC-705 leads on the differences that matter

The largest is module efficiency: 1.10 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter DH108ND-440W DH132NC-705 Difference
Module efficiency 21.60 % 22.70 % 1.10 pp more efficient
Rated power 440 Wp 705 Wp 265 W more power
Power density 215.6 Wp/m² 227.0 Wp/m² 11.4 Wp/m² higher
Weight 21.7 kg 38.3 kg 16.6 kg lighter
Product warranty 25 yrs 15 yrs 10 yrs longer
Open-circuit voltage 38.82 V 48.72 V 9.90 V apart
Short-circuit current 14.58 A 18.38 A 3.80 A apart
Module area 2.041 m² 3.106 m² 1.065 m² apart
Weight per kWp 49.3 kg/kWp 54.3 kg/kWp 5.0 kg/kWp lighter
Voltage at max power 32.10 V 40.62 V 8.52 V apart
Current at max power 13.71 A 17.36 A 3.65 A apart
Cell count 108 132 24 cells apart
Dimensions 1800x1134x30 mm 2384x1303x33 mm 1800x1134x30 mm vs 2384x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.280 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
DH108ND-440W
14,763 kWh
DH132NC-705
23,654 kWh
Lifetime gap
8,891 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario DH108ND-440W DH132NC-705
Standard test conditions 25 °C 100.0% of rated power 440 W 705 W
Cool, bright day 40 °C 95.8% of rated power 422 W 675 W
Typical summer roof 55 °C 91.6% of rated power 403 W 646 W
Hot roof 70 °C 87.4% of rated power 385 W 616 W
03

Full specification

Parameter DH108ND-440W DH132NC-705 Difference
Power and efficiency
Rated power 440 Wp 705 Wp +265 W for DH132NC-705
Module efficiency 21.60 % 22.70 % +1.10 pp for DH132NC-705
Power density 215.6 Wp/m² 227.0 Wp/m² +11.4 Wp/m² for DH132NC-705
Open-circuit voltage 38.82 V 48.72 V 9.90 V apart
Voltage at max power 32.10 V 40.62 V 8.52 V apart
Short-circuit current 14.58 A 18.38 A 3.80 A apart
Current at max power 13.71 A 17.36 A 3.65 A apart
Temperature
Temperature coefficient -0.280 %/°C -0.280 %/°C Same
Mechanical
Dimensions 1800x1134x30 mm 2384x1303x33 mm 1800x1134x30 mm vs 2384x1303x33 mm
Module area 2.041 m² 3.106 m² 1.065 m² apart
Weight 21.7 kg 38.3 kg -16.6 kg for DH108ND-440W
Weight per kWp 49.3 kg/kWp 54.3 kg/kWp -5.0 kg/kWp for DH108ND-440W
Warranty and degradation
Product warranty 25 yrs 15 yrs +10 yrs for DH108ND-440W
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 132 24 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,843 panels
Efficiency
#8,284 vs #3,785
DH132NC-705 leads by 4,499 places
Power density
#8,357 vs #3,846
DH132NC-705 leads by 4,511 places
Heat behaviour
#1,595 vs #1,595
Tied - the same position in the database
Weight
#3,063 vs #9,203
DH108ND-440W leads by 6,140 places
Warranty
#32 vs #32
Tied - the same position in the database
Overall
#8,205 vs #819
DH132NC-705 leads by 7,386 places
05

More useful comparisons

Open the full database
Same series, other bin
DAS Solar
DAS Solar DAS-DH108ND-440W vs DAS Solar DAS-DH108ND-460W
4 differences, the largest is module efficiency
Same series, other bin
DAS Solar
DAS Solar DAS-DH108ND-440W vs DAS Solar DAS-DH108ND-455W
3 differences, the largest is module efficiency
Same series, other bin
DAS Solar
DAS Solar DAS-DH108ND-440W vs DAS Solar DAS-DH108ND-450W
3 differences, the largest is module efficiency
Same series, other bin
DAS Solar
DAS Solar DAS-DH108ND-440W vs DAS Solar DAS-DH108ND-445W
One difference: module efficiency
Same series, other bin
DAS Solar
DAS Solar DAS-DH132NC-705 vs DAS Solar DAS-DH132NC-715
3 differences, the largest is module efficiency
Same series, other bin
DAS Solar
DAS Solar DAS-DH132NC-705 vs DAS Solar DAS-DH132NC-710
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: DAS Solar DAS-DH108ND-440W or DAS Solar DAS-DH132NC-705?
According to our database: DAS Solar DAS-DH132NC-705 has higher module efficiency (22.70% vs 21.60%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of DAS Solar DAS-DH108ND-440W and DAS Solar DAS-DH132NC-705?
DAS Solar DAS-DH108ND-440 W has a module efficiency of 21.60%, while DAS Solar DAS-DH132NC-705 is 22.70%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does DAS Solar DAS-DH108ND-440W use vs DAS Solar DAS-DH132NC-705?
DAS Solar DAS-DH108ND-440 W uses TOPCon cells; DAS Solar DAS-DH132NC-705 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on DAS Solar DAS-DH108ND-440W and DAS Solar DAS-DH132NC-705?
DAS Solar DAS-DH108ND-440 W has a 30 years power warranty; DAS Solar DAS-DH132NC-705 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are DAS Solar DAS-DH108ND-440W and DAS Solar DAS-DH132NC-705 bifacial panels?
Both DAS Solar DAS-DH108ND-440 W and DAS Solar DAS-DH132NC-705 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 4 DAS Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.