BYD NLBK-36-600 vs BYD NLBK-36 585
VS
The verdict
36-600 leads on the differences that matter
The largest is module efficiency: 0.58 pp more efficient. 11 of 19 comparable parameters are identical.
See all 8 differencesHow alike are they
11
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
8 of 19 parameters
What actually differs
Parameter
36-600
36 585
Difference
Module efficiency
23.23 %
22.65 %
0.58 pp more efficient
Temperature coefficient
-0.300 %/°C
-0.278 %/°C
0.022 %/°C better in heat
Power density
232.3 Wp/m²
226.5 Wp/m²
5.8 Wp/m² higher
Rated power
600 Wp
585 Wp
15 W more power
Short-circuit current
14.79 A
13.49 A
1.30 A apart
Open-circuit voltage
51.54 V
53.82 V
2.28 V apart
Voltage at max power
42.96 V
44.90 V
1.94 V apart
Current at max power
13.98 A
13.03 A
0.95 A apart
02
What it means on a roof
Thirty years of production
Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year
36-600
20,131 kWh
36 585
19,628 kWh
Lifetime gap
503 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
36-600
36 585
Standard test conditions
25 °C
100.0% of rated power
600 W
585 W
Cool, bright day
40 °C
95.5% of rated power
573 W
561 W
Typical summer roof
55 °C
91.0% of rated power
546 W
536 W
Hot roof
70 °C
86.5% of rated power
519 W
512 W
03
Full specification
Parameter
36-600
36 585
Difference
Power and efficiency
Rated power
600 Wp
585 Wp
+15 W for 36-600
Module efficiency
23.23 %
22.65 %
+0.58 pp for 36-600
Power density
232.3 Wp/m²
226.5 Wp/m²
+5.8 Wp/m² for 36-600
Open-circuit voltage
51.54 V
53.82 V
2.28 V apart
Voltage at max power
42.96 V
44.90 V
1.94 V apart
Short-circuit current
14.79 A
13.49 A
1.30 A apart
Current at max power
13.98 A
13.03 A
0.95 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.278 %/°C
+0.022 %/°C for 36 585
Mechanical
Dimensions
2278x1134x30 mm
2278x1134x30 mm
Same
Module area
2.583 m²
2.583 m²
Same
Weight
32.0 kg
32.0 kg
Same
Weight per kWp
53.3 kg/kWp
54.7 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
144
Same
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,252
vs
#3,522
36-600 leads by 2,270 places
Power density
#1,252
vs
#3,500
36-600 leads by 2,248 places
Heat behaviour
#6,093
vs
#1,295
36 585 leads by 4,798 places
Weight
#7,236
vs
#9,081
36-600 leads by 1,845 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#2,935
vs
#4,127
36-600 leads by 1,192 places
05
Open the full database
More useful comparisons
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36 600
5 differences, the largest is temperature coefficient
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36-595
One difference: module efficiency
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36 595
6 differences, the largest is temperature coefficient
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36-590
3 differences, the largest is module efficiency
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36 590
8 differences, the largest is temperature coefficient
Same series, other bin
BYD
BYD NLBK-36-600 vs BYD NLBK-36-585
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: BYD NLBK-36-600 or BYD NLBK-36 585?
According to our database: BYD NLBK-36-600 has higher module efficiency (23.23% vs 22.65%); BYD NLBK-36 585 tolerates heat better (temp coeff -0.278%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of BYD NLBK-36-600 and BYD NLBK-36 585?
BYD NLBK-36-600 has a module efficiency of 23.23%, while BYD NLBK-36 585 is 22.65%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does BYD NLBK-36-600 use vs BYD NLBK-36 585?
BYD NLBK-36-600 uses TOPCon cells; BYD NLBK-36 585 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on BYD NLBK-36-600 and BYD NLBK-36 585?
BYD NLBK-36-600 has a 30 years power warranty; BYD NLBK-36 585 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are BYD NLBK-36-600 and BYD NLBK-36 585 bifacial panels?
Both BYD NLBK-36-600 and BYD NLBK-36 585 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.