Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-620-132M12RHSW-GG
Bauer Solar
BS-715-132M12HSW-GG
715 Wp
23.00 %
TOPCon
Bifacial
Incomplete
VS
Bauer Solar
BS-620-132M12RHSW-GG
620 Wp
23.00 %
TOPCon
Bifacial
Incomplete
The verdict
6 differences, and they point both ways
The largest is rated power: 95 W more power. 12 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 6 differencesHow alike are they
12
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 18 parameters
What actually differs
Parameter
715-132M12HSW-GG
620-132M12RHSW-GG
Difference
Rated power
715 Wp
620 Wp
95 W more power
Weight
37.7 kg
32.3 kg
5.4 kg lighter
Short-circuit current
18.56 A
16.11 A
2.45 A apart
Module area
3.106 m²
2.701 m²
0.405 m² apart
Current at max power
17.50 A
15.20 A
2.30 A apart
Dimensions
2384x1303x33 mm
2382x1134x30 mm
2384x1303x33 mm vs 2382x1134x30 mm
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
715-132M12HSW-GG
23,990 kWh
620-132M12RHSW-GG
20,802 kWh
Lifetime gap
3,188 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
715-132M12HSW-GG
620-132M12RHSW-GG
Standard test conditions
25 °C
100.0% of rated power
715 W
620 W
Cool, bright day
40 °C
95.7% of rated power
684 W
593 W
Typical summer roof
55 °C
91.3% of rated power
653 W
566 W
Hot roof
70 °C
87.0% of rated power
622 W
539 W
03
Full specification
Parameter
715-132M12HSW-GG
620-132M12RHSW-GG
Difference
Power and efficiency
Rated power
715 Wp
620 Wp
+95 W for 715-132M12HSW-GG
Module efficiency
23.00 %
23.00 %
Same
Power density
230.2 Wp/m²
229.5 Wp/m²
Effectively the same
Open-circuit voltage
49.02 V
49.09 V
Effectively the same
Voltage at max power
40.93 V
40.85 V
Effectively the same
Short-circuit current
18.56 A
16.11 A
2.45 A apart
Current at max power
17.50 A
15.20 A
2.30 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2384x1303x33 mm
2382x1134x30 mm
2384x1303x33 mm vs 2382x1134x30 mm
Module area
3.106 m²
2.701 m²
0.405 m² apart
Weight
37.7 kg
32.3 kg
-5.4 kg for 620-132M12RHSW-GG
Weight per kWp
52.7 kg/kWp
52.1 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
-
-
Neither datasheet publishes this
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
132
Same
Bifacial
Yes
Yes
Same
04
14,843 panels
Against the whole database
Efficiency
#2,302
vs
#2,302
Tied - the same position in the database
Power density
#2,420
vs
#2,604
715-132M12HSW-GG leads by 184 places
Heat behaviour
#2,527
vs
#2,527
Tied - the same position in the database
Weight
#6,858
vs
#5,945
620-132M12RHSW-GG leads by 913 places
Warranty
#32
vs
#32
Tied - the same position in the database
Overall
#55
vs
#578
715-132M12HSW-GG leads by 523 places
05
Open the full database
More useful comparisons
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-720-132M12HSW-GG
One difference: module efficiency
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-710-132M12HSW-GG
The same specification on paper
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-630-132M12RHSW-GG
8 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-625-132M12RHSW-GG
6 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-600-144M10HSW-GG
10 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-715-132M12HSW-GG vs Bauer Solar BS-595-144M10HSW-GG
9 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Bauer Solar BS-715-132M12HSW-GG or Bauer Solar BS-620-132M12RHSW-GG?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Bauer Solar BS-715-132M12HSW-GG and Bauer Solar BS-620-132M12RHSW-GG?
Bauer Solar BS-715-132M12HSW-GG has a module efficiency of 23.00%, while Bauer Solar BS-620-132M12RHSW-GG is 23.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Bauer Solar BS-715-132M12HSW-GG use vs Bauer Solar BS-620-132M12RHSW-GG?
Bauer Solar BS-715-132M12HSW-GG uses TOPCon cells; Bauer Solar BS-620-132M12RHSW-GG uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Bauer Solar BS-715-132M12HSW-GG and Bauer Solar BS-620-132M12RHSW-GG?
Bauer Solar BS-715-132M12HSW-GG has a 30 years power warranty; Bauer Solar BS-620-132M12RHSW-GG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Bauer Solar BS-715-132M12HSW-GG and Bauer Solar BS-620-132M12RHSW-GG bifacial panels?
Both Bauer Solar BS-715-132M12HSW-GG and Bauer Solar BS-620-132M12RHSW-GG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 Bauer Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.