Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-710-132M12HSW-GG
Bauer Solar
BS-625-132M12RHSW-GG
625 Wp
23.10 %
TOPCon
Bifacial
Incomplete
VS
Bauer Solar
BS-710-132M12HSW-GG
710 Wp
22.90 %
TOPCon
Bifacial
Incomplete
The verdict
7 differences, and they point both ways
The largest is rated power: 85 W more power. 11 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 7 differencesHow alike are they
11
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 18 parameters
What actually differs
Parameter
625-132M12RHSW-GG
710-132M12HSW-GG
Difference
Rated power
625 Wp
710 Wp
85 W more power
Weight
32.3 kg
37.7 kg
5.4 kg lighter
Short-circuit current
16.17 A
18.52 A
2.35 A apart
Module area
2.701 m²
3.106 m²
0.405 m² apart
Module efficiency
23.10 %
22.90 %
0.20 pp more efficient
Current at max power
15.25 A
17.45 A
2.20 A apart
Dimensions
2382x1134x30 mm
2384x1303x33 mm
2382x1134x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
625-132M12RHSW-GG
20,970 kWh
710-132M12HSW-GG
23,822 kWh
Lifetime gap
2,852 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
625-132M12RHSW-GG
710-132M12HSW-GG
Standard test conditions
25 °C
100.0% of rated power
625 W
710 W
Cool, bright day
40 °C
95.7% of rated power
598 W
679 W
Typical summer roof
55 °C
91.3% of rated power
571 W
648 W
Hot roof
70 °C
87.0% of rated power
543 W
617 W
03
Full specification
Parameter
625-132M12RHSW-GG
710-132M12HSW-GG
Difference
Power and efficiency
Rated power
625 Wp
710 Wp
+85 W for 710-132M12HSW-GG
Module efficiency
23.10 %
22.90 %
+0.20 pp for 625-132M12RHSW-GG
Power density
231.4 Wp/m²
228.6 Wp/m²
Effectively the same
Open-circuit voltage
49.29 V
48.82 V
Effectively the same
Voltage at max power
41.05 V
40.76 V
Effectively the same
Short-circuit current
16.17 A
18.52 A
2.35 A apart
Current at max power
15.25 A
17.45 A
2.20 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2382x1134x30 mm
2384x1303x33 mm
2382x1134x30 mm vs 2384x1303x33 mm
Module area
2.701 m²
3.106 m²
0.405 m² apart
Weight
32.3 kg
37.7 kg
-5.4 kg for 625-132M12RHSW-GG
Weight per kWp
51.7 kg/kWp
53.1 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
-
-
Neither datasheet publishes this
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
132
Same
Bifacial
Yes
Yes
Same
04
14,843 panels
Against the whole database
Efficiency
#1,929
vs
#2,784
625-132M12RHSW-GG leads by 855 places
Power density
#1,861
vs
#2,910
625-132M12RHSW-GG leads by 1,049 places
Heat behaviour
#2,527
vs
#2,527
Tied - the same position in the database
Weight
#5,418
vs
#7,374
625-132M12RHSW-GG leads by 1,956 places
Warranty
#32
vs
#32
Tied - the same position in the database
Overall
#488
vs
#68
710-132M12HSW-GG leads by 420 places
05
Open the full database
More useful comparisons
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-720-132M12HSW-GG
6 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-715-132M12HSW-GG
6 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-630-132M12RHSW-GG
One difference: module efficiency
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-620-132M12RHSW-GG
The same specification on paper
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-600-144M10HSW-GG
8 differences, the largest is rated power
Same series, other bin
Bauer Solar
Bauer Solar BS-625-132M12RHSW-GG vs Bauer Solar BS-595-144M10HSW-GG
8 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Bauer Solar BS-625-132M12RHSW-GG or Bauer Solar BS-710-132M12HSW-GG?
According to our database: Bauer Solar BS-625-132M12RHSW-GG has higher module efficiency (23.10% vs 22.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Bauer Solar BS-625-132M12RHSW-GG and Bauer Solar BS-710-132M12HSW-GG?
Bauer Solar BS-625-132M12RHSW-GG has a module efficiency of 23.10%, while Bauer Solar BS-710-132M12HSW-GG is 22.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Bauer Solar BS-625-132M12RHSW-GG use vs Bauer Solar BS-710-132M12HSW-GG?
Bauer Solar BS-625-132M12RHSW-GG uses TOPCon cells; Bauer Solar BS-710-132M12HSW-GG uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Bauer Solar BS-625-132M12RHSW-GG and Bauer Solar BS-710-132M12HSW-GG?
Bauer Solar BS-625-132M12RHSW-GG has a 30 years power warranty; Bauer Solar BS-710-132M12HSW-GG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Bauer Solar BS-625-132M12RHSW-GG and Bauer Solar BS-710-132M12HSW-GG bifacial panels?
Both Bauer Solar BS-625-132M12RHSW-GG and Bauer Solar BS-710-132M12HSW-GG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 Bauer Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.