Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM66N(DG)/F-BH-715
VS
The verdict
CHSM48RN(DG)/F-BH-460 leads on the differences that matter
The largest is rated power: 255 W more power. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
CHSM48RN(DG)/F-BH-460
CHSM66N(DG)/F-BH-715
Difference
Rated power
460 Wp
715 Wp
255 W more power
Weight
24.5 kg
38.0 kg
13.5 kg lighter
Product warranty
25 yrs
15 yrs
10 yrs longer
Open-circuit voltage
36.74 V
48.97 V
12.23 V apart
Short-circuit current
15.88 A
18.53 A
2.65 A apart
Module area
1.998 m²
3.106 m²
1.108 m² apart
Voltage at max power
30.60 V
40.65 V
10.05 V apart
Current at max power
15.03 A
17.59 A
2.56 A apart
Cell count
96
132
36 cells apart
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
CHSM48RN(DG)/F-BH-460
15,434 kWh
CHSM66N(DG)/F-BH-715
23,990 kWh
Lifetime gap
8,556 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
CHSM48RN(DG)/F-BH-460
CHSM66N(DG)/F-BH-715
Standard test conditions
25 °C
100.0% of rated power
460 W
715 W
Cool, bright day
40 °C
95.7% of rated power
440 W
684 W
Typical summer roof
55 °C
91.3% of rated power
420 W
653 W
Hot roof
70 °C
87.0% of rated power
400 W
622 W
03
Full specification
Parameter
CHSM48RN(DG)/F-BH-460
CHSM66N(DG)/F-BH-715
Difference
Power and efficiency
Rated power
460 Wp
715 Wp
+255 W for CHSM66N(DG)/F-BH-715
Module efficiency
23.00 %
23.00 %
Same
Power density
230.2 Wp/m²
230.2 Wp/m²
Same
Open-circuit voltage
36.74 V
48.97 V
12.23 V apart
Voltage at max power
30.60 V
40.65 V
10.05 V apart
Short-circuit current
15.88 A
18.53 A
2.65 A apart
Current at max power
15.03 A
17.59 A
2.56 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
Module area
1.998 m²
3.106 m²
1.108 m² apart
Weight
24.5 kg
38.0 kg
-13.5 kg for CHSM48RN(DG)/F-BH-460
Weight per kWp
53.3 kg/kWp
53.1 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
25 yrs
15 yrs
+10 yrs for CHSM48RN(DG)/F-BH-460
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
132
36 cells apart
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#2,049
vs
#2,049
Tied - the same position in the database
Power density
#2,011
vs
#2,158
CHSM48RN(DG)/F-BH-460 leads by 147 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#7,265
vs
#7,101
CHSM66N(DG)/F-BH-715 leads by 164 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#5,475
vs
#490
CHSM66N(DG)/F-BH-715 leads by 4,985 places
05
Open the full database
More useful comparisons
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)/F-BH-475
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-470
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)/F-BH-470
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)/F-BH-465
One difference: module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-465
One difference: module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)/F-BH-460 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-460
The same specification on paper
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Astronergy CHSM48RN(DG)/F-BH-460 or Astronergy CHSM66N(DG)/F-BH-715?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Astronergy CHSM48RN(DG)/F-BH-460 and Astronergy CHSM66N(DG)/F-BH-715?
Astronergy CHSM48RN(DG)/F-BH-460 has a module efficiency of 23.00%, while Astronergy CHSM66N(DG)/F-BH-715 is 23.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Astronergy CHSM48RN(DG)/F-BH-460 use vs Astronergy CHSM66N(DG)/F-BH-715?
Astronergy CHSM48RN(DG)/F-BH-460 uses TOPCon cells; Astronergy CHSM66N(DG)/F-BH-715 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Astronergy CHSM48RN(DG)/F-BH-460 and Astronergy CHSM66N(DG)/F-BH-715?
Astronergy CHSM48RN(DG)/F-BH-460 has a 30 years power warranty; Astronergy CHSM66N(DG)/F-BH-715 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Astronergy CHSM48RN(DG)/F-BH-460 and Astronergy CHSM66N(DG)/F-BH-715 bifacial panels?
Both Astronergy CHSM48RN(DG)/F-BH-460 and Astronergy CHSM66N(DG)/F-BH-715 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 35 Astronergy offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.