Skip to main content
AS650G12-120 vs AS675G12-132 9 of 19 identical Swap Change panels

AmoSolar AS650G12-120 vs AmoSolar AS675G12-132

AmoSolar
AS650G12-120
650 Wp 20.90 % PERC Bifacial
VS
AmoSolar AS675G12-132
AmoSolar
AS675G12-132
675 Wp 21.73 % PERC
The verdict

AS675G12-132 leads on the differences that matter

The largest is module efficiency: 0.83 pp more efficient. 9 of 19 comparable parameters are identical.

See all 10 differences
How alike are they
9 of 19 comparable
parameters are identical
identical differs
01

What actually differs

10 of 19 parameters
Parameter AS650G12-120 AS675G12-132 Difference
Module efficiency 20.90 % 21.73 % 0.83 pp more efficient
Performance warranty 30 yrs 25 yrs 5 yrs longer
Weight 38.7 kg 33.0 kg 5.7 kg lighter
Weight per kWp 59.5 kg/kWp 48.9 kg/kWp 10.6 kg/kWp lighter
Power density 209.2 Wp/m² 217.3 Wp/m² 8.0 Wp/m² higher
Rated power 650 Wp 675 Wp 25 W more power
Annual degradation 0.50 %/yr 0.55 %/yr 0.05 %/yr slower
Bifacial Yes No Yes vs No
Open-circuit voltage 45.20 V 46.44 V 1.24 V apart
Voltage at max power 37.40 V 39.00 V 1.60 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.340 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
AS650G12-120
21,119 kWh
AS675G12-132
21,876 kWh
Lifetime gap
757 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AS650G12-120 AS675G12-132
Standard test conditions 25 °C 100.0% of rated power 650 W 675 W
Cool, bright day 40 °C 94.9% of rated power 617 W 641 W
Typical summer roof 55 °C 89.8% of rated power 584 W 606 W
Hot roof 70 °C 84.7% of rated power 551 W 572 W
03

Full specification

Parameter AS650G12-120 AS675G12-132 Difference
Power and efficiency
Rated power 650 Wp 675 Wp +25 W for AS675G12-132
Module efficiency 20.90 % 21.73 % +0.83 pp for AS675G12-132
Power density 209.2 Wp/m² 217.3 Wp/m² +8.0 Wp/m² for AS675G12-132
Open-circuit voltage 45.20 V 46.44 V 1.24 V apart
Voltage at max power 37.40 V 39.00 V 1.60 V apart
Short-circuit current 18.46 A 18.38 A Effectively the same
Current at max power 17.38 A 17.31 A Effectively the same
Temperature
Temperature coefficient -0.340 %/°C -0.340 %/°C Same
Mechanical
Dimensions 2384x1303x35 mm 2384x1303x35 mm Same
Module area 3.106 m² 3.106 m² Same
Weight 38.7 kg 33.0 kg -5.7 kg for AS675G12-132
Weight per kWp 59.5 kg/kWp 48.9 kg/kWp -10.6 kg/kWp for AS675G12-132
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 25 yrs +5 yrs for AS650G12-120
Annual degradation 0.50 %/yr 0.55 %/yr -0.05 %/yr for AS650G12-120
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes No Yes vs No
04

Against the whole database

14,354 panels
Efficiency
#10,311 vs #7,577
AS675G12-132 leads by 2,734 places
Power density
#10,247 vs #7,556
AS675G12-132 leads by 2,691 places
Heat behaviour
#9,020 vs #9,020
Tied - the same position in the database
Weight
#12,470 vs #2,587
AS675G12-132 leads by 9,883 places
Warranty
#31 vs #10,073
AS650G12-120 leads by 10,042 places
Overall
#4,073 vs #3,083
AS675G12-132 leads by 990 places
05

More useful comparisons

Open the full database
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS675G12-120
6 differences, the largest is module efficiency
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS670G12-120
3 differences, the largest is module efficiency
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS665G12-120
3 differences, the largest is module efficiency
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS660G12-120
3 differences, the largest is module efficiency
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS655G12-120
The same specification on paper
Same series, other bin
AmoSolar
AmoSolar AS650G12-120 vs AmoSolar AS645G12-120
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AmoSolar AS650G12-120 or AmoSolar AS675G12-132?
According to our database: AmoSolar AS675G12-132 has higher module efficiency (21.73% vs 20.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AmoSolar AS650G12-120 and AmoSolar AS675G12-132?
AmoSolar AS650G12-120 has a module efficiency of 20.90%, while AmoSolar AS675G12-132 is 21.73%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AmoSolar AS650G12-120 use vs AmoSolar AS675G12-132?
AmoSolar AS650G12-120 uses PERC cells; AmoSolar AS675G12-132 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AmoSolar AS650G12-120 and AmoSolar AS675G12-132?
AmoSolar AS650G12-120 has a 30 years power warranty; AmoSolar AS675G12-132 has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AmoSolar AS650G12-120 and AmoSolar AS675G12-132 bifacial panels?
AmoSolar AS650G12-120 is bifacial (captures light from both faces); AmoSolar AS675G12-132 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.