Skip to main content
AIKO-A800-GRH78Dw vs SPR-BE66-GD610 5 of 17 identical Swap Change panels

AIKO AIKO-A800-GRH78Dw vs Maxeon SPR-BE66-GD610

AIKO AIKO-A800-GRH78Dw
AIKO-A800-GRH78Dw
800 Wp 24.90 % Back Contact Bifacial Incomplete
VS
Maxeon
SPR-BE66-GD610
610 Wp 24.60 % Back Contact Bifacial
The verdict

12 differences, and they point both ways

The largest is rated power: 190 W more power. 5 of 17 comparable parameters are identical, with 2 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
5 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 17 parameters
Parameter AIKO-A800-GRH78Dw SPR-BE66-GD610 Difference
Rated power 800 Wp 610 Wp 190 W more power
Performance warranty 30 yrs 40 yrs 10 yrs longer
Weight 39.8 kg 30.1 kg 9.7 kg lighter
Product warranty 15 yrs 40 yrs 25 yrs longer
Open-circuit voltage 59.32 V 49.83 V 9.49 V apart
Module area 3.212 m² 2.483 m² 0.728 m² apart
Module efficiency 24.90 % 24.60 % 0.30 pp more efficient
Short-circuit current 17.06 A 15.46 A 1.60 A apart
Power density 249.1 Wp/m² 245.6 Wp/m² 3.4 Wp/m² higher
Voltage at max power 49.36 V 41.56 V 7.80 V apart
Current at max power 16.21 A 14.68 A 1.53 A apart
Dimensions 2465x1303x33 mm 2190x1134x30 mm 2465x1303x33 mm vs 2190x1134x30 mm
02

What it means on a roof

Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.260 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
AIKO-A800-GRH78Dw
26,842 kWh
SPR-BE66-GD610
20,467 kWh
Lifetime gap
6,375 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AIKO-A800-GRH78Dw SPR-BE66-GD610
Standard test conditions 25 °C 100.0% of rated power 800 W 610 W
Cool, bright day 40 °C 96.1% of rated power 769 W 586 W
Typical summer roof 55 °C 92.2% of rated power 738 W 562 W
Hot roof 70 °C 88.3% of rated power 706 W 539 W
03

Full specification

Parameter AIKO-A800-GRH78Dw SPR-BE66-GD610 Difference
Power and efficiency
Rated power 800 Wp 610 Wp +190 W for AIKO-A800-GRH78Dw
Module efficiency 24.90 % 24.60 % +0.30 pp for AIKO-A800-GRH78Dw
Power density 249.1 Wp/m² 245.6 Wp/m² +3.4 Wp/m² for AIKO-A800-GRH78Dw
Open-circuit voltage 59.32 V 49.83 V 9.49 V apart
Voltage at max power 49.36 V 41.56 V 7.80 V apart
Short-circuit current 17.06 A 15.46 A 1.60 A apart
Current at max power 16.21 A 14.68 A 1.53 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.260 %/°C Same
Mechanical
Dimensions 2465x1303x33 mm 2190x1134x30 mm 2465x1303x33 mm vs 2190x1134x30 mm
Module area 3.212 m² 2.483 m² 0.728 m² apart
Weight 39.8 kg 30.1 kg -9.7 kg for SPR-BE66-GD610
Weight per kWp 49.7 kg/kWp 49.3 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 40 yrs +25 yrs for SPR-BE66-GD610
Performance warranty 30 yrs 40 yrs +10 yrs for SPR-BE66-GD610
Annual degradation - 0.25 %/yr Not published by AIKO
Technology
Cell technology Back Contact Back Contact Same
Cell type Monocrystalline Monocrystalline Same
Cell count 156 - Not published by Maxeon
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#15 vs #73
AIKO-A800-GRH78Dw leads by 58 places
Power density
#15 vs #99
AIKO-A800-GRH78Dw leads by 84 places
Heat behaviour
#521 vs #521
Tied - the same position in the database
Weight
#3,256 vs #2,900
SPR-BE66-GD610 leads by 356 places
Warranty
#31 vs #1
SPR-BE66-GD610 leads by 30 places
Overall
#4 vs #3
SPR-BE66-GD610 leads by 1 place
05

More useful comparisons

Open the full database
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A805-GRH78Dw
One difference: module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A795-GRH78Dw
The same specification on paper
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A790-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A785-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A780-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A775-GRH78Dw
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AIKO AIKO-A800-GRH78Dw or Maxeon SPR-BE66-GD610?
According to our database: AIKO AIKO-A800-GRH78Dw has higher module efficiency (24.90% vs 24.60%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO AIKO-A800-GRH78Dw and Maxeon SPR-BE66-GD610?
AIKO AIKO-A800-GRH78Dw has a module efficiency of 24.90%, while Maxeon SPR-BE66-GD610 is 24.60%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO AIKO-A800-GRH78Dw use vs Maxeon SPR-BE66-GD610?
AIKO AIKO-A800-GRH78Dw uses Back Contact cells; Maxeon SPR-BE66-GD610 uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO AIKO-A800-GRH78Dw and Maxeon SPR-BE66-GD610?
AIKO AIKO-A800-GRH78Dw has a 30 years power warranty; Maxeon SPR-BE66-GD610 has a 40 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AIKO AIKO-A800-GRH78Dw and Maxeon SPR-BE66-GD610 bifacial panels?
Both AIKO AIKO-A800-GRH78Dw and Maxeon SPR-BE66-GD610 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Compare AIKO and Maxeon as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 142 AIKO offers · See 19 Maxeon offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.