Skip to main content
AIKO-A495-MCE54Mw vs UL-450M-108BDGN 6 of 19 identical Swap Change panels

AIKO AIKO-A495-MCE54Mw vs Ulica Solar UL-450M-108BDGN

AIKO AIKO-A495-MCE54Mw
AIKO-A495-MCE54Mw
495 Wp 24.80 % Back Contact
VS
Ulica Solar UL-450M-108BDGN
Ulica Solar
UL-450M-108BDGN
450 Wp 22.52 % TOPCon Bifacial
The verdict

AIKO-A495-MCE54Mw leads on the differences that matter

The largest is module efficiency: 2.28 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter AIKO-A495-MCE54Mw UL-450M-108BDGN Difference
Module efficiency 24.80 % 22.52 % 2.28 pp more efficient
Rated power 495 Wp 450 Wp 45 W more power
Power density 247.7 Wp/m² 225.2 Wp/m² 22.5 Wp/m² higher
Temperature coefficient -0.260 %/°C -0.290 %/°C 0.030 %/°C better in heat
Weight per kWp 42.4 kg/kWp 53.3 kg/kWp 10.9 kg/kWp lighter
Weight 21.0 kg 24.0 kg 3.0 kg lighter
Cell technology Back Contact TOPCon Back Contact vs TOPCon
Annual degradation 0.35 %/yr 0.40 %/yr 0.05 %/yr slower
Bifacial No Yes No vs Yes
Open-circuit voltage 41.10 V 39.78 V 1.32 V apart
Short-circuit current 15.00 A 14.38 A 0.62 A apart
Current at max power 14.35 A 13.55 A 0.80 A apart
Voltage at max power 34.50 V 33.22 V 1.28 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AIKO-A495-MCE54Mw
16,737 kWh
UL-450M-108BDGN
15,098 kWh
Lifetime gap
1,639 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AIKO-A495-MCE54Mw UL-450M-108BDGN
Standard test conditions 25 °C 100.0% of rated power 495 W 450 W
Cool, bright day 40 °C 95.7% of rated power 476 W 430 W
Typical summer roof 55 °C 91.3% of rated power 456 W 411 W
Hot roof 70 °C 87.0% of rated power 437 W 391 W
03

Full specification

Parameter AIKO-A495-MCE54Mw UL-450M-108BDGN Difference
Power and efficiency
Rated power 495 Wp 450 Wp +45 W for AIKO-A495-MCE54Mw
Module efficiency 24.80 % 22.52 % +2.28 pp for AIKO-A495-MCE54Mw
Power density 247.7 Wp/m² 225.2 Wp/m² +22.5 Wp/m² for AIKO-A495-MCE54Mw
Open-circuit voltage 41.10 V 39.78 V 1.32 V apart
Voltage at max power 34.50 V 33.22 V 1.28 V apart
Short-circuit current 15.00 A 14.38 A 0.62 A apart
Current at max power 14.35 A 13.55 A 0.80 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.290 %/°C +0.030 %/°C for AIKO-A495-MCE54Mw
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 21.0 kg 24.0 kg -3.0 kg for AIKO-A495-MCE54Mw
Weight per kWp 42.4 kg/kWp 53.3 kg/kWp -10.9 kg/kWp for AIKO-A495-MCE54Mw
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr 0.40 %/yr -0.05 %/yr for AIKO-A495-MCE54Mw
Technology
Cell technology Back Contact TOPCon Back Contact vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial No Yes No vs Yes
04

Against the whole database

14,354 panels
Efficiency
#17 vs #4,277
AIKO-A495-MCE54Mw leads by 4,260 places
Power density
#48 vs #4,400
AIKO-A495-MCE54Mw leads by 4,352 places
Heat behaviour
#521 vs #2,288
AIKO-A495-MCE54Mw leads by 1,767 places
Weight
#219 vs #7,341
AIKO-A495-MCE54Mw leads by 7,122 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#4,073 vs #8,696
AIKO-A495-MCE54Mw leads by 4,623 places
05

More useful comparisons

Open the full database
Same series, other bin
AIKO AIKO-A495-MCE54Mw vs AIKO AIKO-A490-MCE54Mw
One difference: module efficiency
Same series, other bin
AIKO AIKO-A495-MCE54Mw vs AIKO AIKO-A485-MCE54Mw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A495-MCE54Mw vs AIKO AIKO-A480-MCE54Mw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A495-MCE54Mw vs AIKO AIKO-A475-MCE54Mw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A495-MCE54Mw vs AIKO AIKO-A470-MCE54Mw
5 differences, the largest is module efficiency
Same series, other bin
Ulica Solar
Ulica Solar UL-450M-108BDGN vs Ulica Solar UL-505M-120BDGN
8 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AIKO AIKO-A495-MCE54Mw or Ulica Solar UL-450M-108BDGN?
According to our database: AIKO AIKO-A495-MCE54Mw has higher module efficiency (24.80% vs 22.52%); AIKO AIKO-A495-MCE54Mw tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO AIKO-A495-MCE54Mw and Ulica Solar UL-450M-108BDGN?
AIKO AIKO-A495-MCE54Mw has a module efficiency of 24.80%, while Ulica Solar UL-450M-108BDGN is 22.52%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO AIKO-A495-MCE54Mw use vs Ulica Solar UL-450M-108BDGN?
AIKO AIKO-A495-MCE54Mw uses Back Contact cells; Ulica Solar UL-450M-108BDGN uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO AIKO-A495-MCE54Mw and Ulica Solar UL-450M-108BDGN?
AIKO AIKO-A495-MCE54Mw has a 30 years power warranty; Ulica Solar UL-450M-108BDGN has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AIKO AIKO-A495-MCE54Mw and Ulica Solar UL-450M-108BDGN bifacial panels?
Ulica Solar UL-450M-108BDGN is bifacial (captures light from both faces); AIKO AIKO-A495-MCE54Mw is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare AIKO and Ulica Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 140 AIKO offers · See 4 Ulica Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.