CME-132BDS-725 vs LX-720M/210-132+GG 9 of 18 identical Swap Change panels

AE Solar CME-132BDS-725 vs Luxor Solar LX-720M/210-132+GG

AE Solar CME-132BDS-725
CME-132BDS-725
725 Wp 23.37 % TOPCon Bifacial
VS
Luxor Solar
LX-720M/210-132+GG
720 Wp 23.39 % HJT Bifacial Incomplete
The verdict

LX-720M/210-132+GG leads on the differences that matter

The largest is temperature coefficient: 0.050 %/°C better in heat. 9 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 9 differences
How alike are they
9 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 18 parameters
Parameter CME-132BDS-725 LX-720M/210-132+GG Difference
Temperature coefficient -0.290 %/°C -0.240 %/°C 0.050 %/°C better in heat
Weight 37.0 kg 38.7 kg 1.7 kg lighter
Cell technology TOPCon HJT TOPCon vs HJT
Open-circuit voltage 49.30 V 51.39 V 2.09 V apart
Weight per kWp 51.0 kg/kWp 53.8 kg/kWp 2.7 kg/kWp lighter
Short-circuit current 18.46 A 17.54 A 0.92 A apart
Voltage at max power 41.50 V 43.68 V 2.18 V apart
Dimensions 2383x1302x30 mm 2384x1303x35 mm 2383x1302x30 mm vs 2384x1303x35 mm
Current at max power 17.47 A 16.49 A 0.98 A apart
02

What it means on a roof

Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
CME-132BDS-725
24,325 kWh
LX-720M/210-132+GG
24,157 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario CME-132BDS-725 LX-720M/210-132+GG
Standard test conditions 25 °C 100.0% of rated power 725 W 720 W
Cool, bright day 40 °C 95.7% of rated power 693 W 694 W
Typical summer roof 55 °C 91.3% of rated power 662 W 668 W
Hot roof 70 °C 87.0% of rated power 630 W 642 W
03

Full specification

Parameter CME-132BDS-725 LX-720M/210-132+GG Difference
Power and efficiency
Rated power 725 Wp 720 Wp Effectively the same
Module efficiency 23.37 % 23.39 % Effectively the same
Power density 233.7 Wp/m² 231.8 Wp/m² Effectively the same
Open-circuit voltage 49.30 V 51.39 V 2.09 V apart
Voltage at max power 41.50 V 43.68 V 2.18 V apart
Short-circuit current 18.46 A 17.54 A 0.92 A apart
Current at max power 17.47 A 16.49 A 0.98 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.240 %/°C +0.050 %/°C for LX-720M/210-132+GG
Mechanical
Dimensions 2383x1302x30 mm 2384x1303x35 mm 2383x1302x30 mm vs 2384x1303x35 mm
Module area 3.103 m² 3.106 m² Effectively the same
Weight 37.0 kg 38.7 kg -1.7 kg for CME-132BDS-725
Weight per kWp 51.0 kg/kWp 53.8 kg/kWp -2.7 kg/kWp for CME-132BDS-725
Warranty and degradation
Product warranty 30 yrs 30 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr - Not published by Luxor Solar
Technology
Cell technology TOPCon HJT TOPCon vs HJT
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#1,031 vs #1,026
LX-720M/210-132+GG leads by 5 places
Power density
#1,024 vs #1,460
CME-132BDS-725 leads by 436 places
Heat behaviour
#2,288 vs #13
LX-720M/210-132+GG leads by 2,275 places
Weight
#4,460 vs #7,988
CME-132BDS-725 leads by 3,528 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#16 vs #22
CME-132BDS-725 leads by 6 places
05

More useful comparisons

Open the full database
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-730
The same specification on paper
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-730W
One difference: product warranty
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-725W
One difference: product warranty
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-720
The same specification on paper
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-720W
One difference: product warranty
Same series, other bin
AE Solar CME-132BDS-725 vs AE Solar CME-132BDS-715
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AE Solar CME-132BDS-725 or Luxor Solar LX-720M/210-132+GG?
According to our database: Luxor Solar LX-720M/210-132+GG has higher module efficiency (23.39% vs 23.37%); Luxor Solar LX-720M/210-132+GG tolerates heat better (temp coeff -0.240%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AE Solar CME-132BDS-725 and Luxor Solar LX-720M/210-132+GG?
AE Solar CME-132BDS-725 has a module efficiency of 23.37%, while Luxor Solar LX-720M/210-132+GG is 23.39%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AE Solar CME-132BDS-725 use vs Luxor Solar LX-720M/210-132+GG?
AE Solar CME-132BDS-725 uses TOPCon cells; Luxor Solar LX-720M/210-132+GG uses HJT. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AE Solar CME-132BDS-725 and Luxor Solar LX-720M/210-132+GG?
AE Solar CME-132BDS-725 has a 30 years power warranty; Luxor Solar LX-720M/210-132+GG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AE Solar CME-132BDS-725 and Luxor Solar LX-720M/210-132+GG bifacial panels?
Both AE Solar CME-132BDS-725 and Luxor Solar LX-720M/210-132+GG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Compare AE Solar and Luxor Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 3 AE Solar offers · See 4 Luxor Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.