AE ME-132-660 vs MD-144BS-545W 7 of 19 identical Swap Change panels

AE Solar AE ME-132-660 vs AE Solar MD-144BS-545W

AE Solar AE ME-132-660
AE ME-132-660
660 Wp 21.27 % PERC
VS
AE Solar MD-144BS-545W
MD-144BS-545W
545 Wp 21.12 % PERC Bifacial
The verdict

AE ME-132-660 leads on the differences that matter

The largest is rated power: 115 W more power. 7 of 19 comparable parameters are identical.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs
01

What actually differs

12 of 19 parameters
Parameter AE ME-132-660 MD-144BS-545W Difference
Rated power 660 Wp 545 Wp 115 W more power
Weight 31.5 kg 26.5 kg 5.0 kg lighter
Product warranty 30 yrs 15 yrs 15 yrs longer
Open-circuit voltage 45.90 V 50.01 V 4.11 V apart
Short-circuit current 18.43 A 13.62 A 4.81 A apart
Module area 3.103 m² 2.581 m² 0.522 m² apart
Temperature coefficient -0.340 %/°C -0.350 %/°C 0.010 %/°C better in heat
Voltage at max power 37.80 V 42.38 V 4.58 V apart
Current at max power 17.46 A 12.86 A 4.60 A apart
Cell count 132 144 12 cells apart
Bifacial No Yes No vs Yes
Dimensions 2383x1302x30 mm 2278x1133x30 mm 2383x1302x30 mm vs 2278x1133x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AE ME-132-660
21,271 kWh
MD-144BS-545W
17,565 kWh
Lifetime gap
3,706 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AE ME-132-660 MD-144BS-545W
Standard test conditions 25 °C 100.0% of rated power 660 W 545 W
Cool, bright day 40 °C 94.8% of rated power 626 W 516 W
Typical summer roof 55 °C 89.5% of rated power 593 W 488 W
Hot roof 70 °C 84.2% of rated power 559 W 459 W
03

Full specification

Parameter AE ME-132-660 MD-144BS-545W Difference
Power and efficiency
Rated power 660 Wp 545 Wp +115 W for AE ME-132-660
Module efficiency 21.27 % 21.12 % Effectively the same
Power density 212.7 Wp/m² 211.2 Wp/m² Effectively the same
Open-circuit voltage 45.90 V 50.01 V 4.11 V apart
Voltage at max power 37.80 V 42.38 V 4.58 V apart
Short-circuit current 18.43 A 13.62 A 4.81 A apart
Current at max power 17.46 A 12.86 A 4.60 A apart
Temperature
Temperature coefficient -0.340 %/°C -0.350 %/°C +0.010 %/°C for AE ME-132-660
Mechanical
Dimensions 2383x1302x30 mm 2278x1133x30 mm 2383x1302x30 mm vs 2278x1133x30 mm
Module area 3.103 m² 2.581 m² 0.522 m² apart
Weight 31.5 kg 26.5 kg -5.0 kg for MD-144BS-545W
Weight per kWp 47.7 kg/kWp 48.6 kg/kWp Effectively the same
Warranty and degradation
Product warranty 30 yrs 15 yrs +15 yrs for AE ME-132-660
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.55 %/yr 0.55 %/yr Same
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 144 12 cells apart
Bifacial No Yes No vs Yes
04

Against the whole database

14,005 panels
Efficiency
#8,849 vs #9,255
AE ME-132-660 leads by 406 places
Power density
#8,718 vs #9,256
AE ME-132-660 leads by 538 places
Heat behaviour
#8,778 vs #10,419
AE ME-132-660 leads by 1,641 places
Weight
#1,829 vs #2,373
AE ME-132-660 leads by 544 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#784 vs #6,577
AE ME-132-660 leads by 5,793 places
05

More useful comparisons

Open the full database
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar ME-132BD-660
4 differences, the largest is weight
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar AE ME-132 660W
The same specification on paper
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar AE ME-132BD-660
3 differences, the largest is weight
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar ME-132-660
One difference: product warranty
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar ME-132BD-655
4 differences, the largest is weight
Same series, other bin
AE Solar AE ME-132-660 vs AE Solar AE ME-132 655W
The same specification on paper
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AE Solar AE ME-132-660 or AE Solar MD-144BS-545W?
According to our database: AE Solar AE ME-132-660 has higher module efficiency (21.27% vs 21.12%); AE Solar AE ME-132-660 tolerates heat better (temp coeff -0.340%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AE Solar AE ME-132-660 and AE Solar MD-144BS-545W?
AE Solar AE ME-132-660 has a module efficiency of 21.27%, while AE Solar MD-144BS-545 W is 21.12%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AE Solar AE ME-132-660 use vs AE Solar MD-144BS-545W?
AE Solar AE ME-132-660 uses PERC cells; AE Solar MD-144BS-545 W uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AE Solar AE ME-132-660 and AE Solar MD-144BS-545W?
AE Solar AE ME-132-660 has a 30 years power warranty; AE Solar MD-144BS-545 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AE Solar AE ME-132-660 and AE Solar MD-144BS-545W bifacial panels?
AE Solar MD-144BS-545 W is bifacial (captures light from both faces); AE Solar AE ME-132-660 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 5 AE Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.