AE Solar AE MD-120 460W vs AE Solar AE MD-120 440W-460W (Pmax 460W class)
VS
The verdict
One difference, none of them an advantage
The largest is cell technology: TOPCon vs PERC. 17 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See the one differenceHow alike are they
17
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
1 of 18 parameters
What actually differs
Parameter
460W
440W-460W (Pmax 460W class)
Difference
Cell technology
TOPCon
PERC
TOPCon vs PERC
02
What it means on a roof
Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.350 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
460W
15,186 kWh
440W-460W (Pmax 460W class)
15,186 kWh
Lifetime gap
No difference
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
460W
440W-460W (Pmax 460W class)
Standard test conditions
25 °C
100.0% of rated power
460 W
460 W
Cool, bright day
40 °C
94.8% of rated power
436 W
436 W
Typical summer roof
55 °C
89.5% of rated power
412 W
412 W
Hot roof
70 °C
84.2% of rated power
388 W
388 W
03
Full specification
Parameter
460W
440W-460W (Pmax 460W class)
Difference
Power and efficiency
Rated power
460 Wp
460 Wp
Same
Module efficiency
21.35 %
21.35 %
Same
Power density
213.5 Wp/m²
213.5 Wp/m²
Same
Open-circuit voltage
42.60 V
42.60 V
Same
Voltage at max power
35.60 V
35.60 V
Same
Short-circuit current
13.67 A
13.67 A
Same
Current at max power
12.92 A
12.92 A
Same
Temperature
Temperature coefficient
-0.350 %/°C
-0.350 %/°C
Same
Mechanical
Dimensions
1902x1133x30 mm
1902x1133x30 mm
Same
Module area
2.155 m²
2.155 m²
Same
Weight
22.5 kg
22.5 kg
Same
Weight per kWp
48.9 kg/kWp
48.9 kg/kWp
Same
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.55 %/yr
-
Not published by AE Solar
Technology
Cell technology
TOPCon
PERC
TOPCon vs PERC
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
120
120
Same
Bifacial
No
No
Same
04
14,129 panels
Against the whole database
Efficiency
#8,528
vs
#8,528
Tied - the same position in the database
Power density
#8,487
vs
#8,487
Tied - the same position in the database
Heat behaviour
#10,489
vs
#10,489
Tied - the same position in the database
Weight
#2,595
vs
#2,595
Tied - the same position in the database
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#6,117
vs
#6,117
Tied - the same position in the database
05
Open the full database
More useful comparisons
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar ME-132BD-660
14 differences, the largest is rated power
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar AE ME-132 660W
11 differences, the largest is rated power
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar AE ME-132BD-660
13 differences, the largest is rated power
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar AE ME-132-660
11 differences, the largest is rated power
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar ME-132-660
12 differences, the largest is rated power
Same series, other bin
AE Solar AE MD-120 460W vs AE Solar ME-132BD-655
15 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: AE Solar AE MD-120 460W or AE Solar AE MD-120 440W-460W (Pmax 460W class)?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AE Solar AE MD-120 460W and AE Solar AE MD-120 440W-460W (Pmax 460W class)?
AE Solar AE MD-120 460 W has a module efficiency of 21.35%, while AE Solar AE MD-120 440 W-460 W (Pmax 460 W class) is 21.35%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AE Solar AE MD-120 460W use vs AE Solar AE MD-120 440W-460W (Pmax 460W class)?
AE Solar AE MD-120 460 W uses TOPCon cells; AE Solar AE MD-120 440 W-460 W (Pmax 460 W class) uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AE Solar AE MD-120 460W and AE Solar AE MD-120 440W-460W (Pmax 460W class)?
AE Solar AE MD-120 460 W has a 30 years power warranty; AE Solar AE MD-120 440 W-460 W (Pmax 460 W class) has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Shop prices: See 4 AE Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.