Skip to main content
AB-G12R-132-635 vs ASB-M12-132-645 7 of 19 identical Swap Change panels

Adani Solar AB-G12R-132-635 vs Adani Solar ASB-M12-132-645

Adani Solar
AB-G12R-132-635
635 Wp 23.53 % TOPCon Bifacial
VS
Adani Solar
ASB-M12-132-645
645 Wp 20.71 % PERC Bifacial
The verdict

AB-G12R-132-635 leads on the differences that matter

The largest is module efficiency: 2.82 pp more efficient. 7 of 19 comparable parameters are identical.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs
01

What actually differs

12 of 19 parameters
Parameter AB-G12R-132-635 ASB-M12-132-645 Difference
Module efficiency 23.53 % 20.71 % 2.82 pp more efficient
Temperature coefficient -0.280 %/°C -0.350 %/°C 0.070 %/°C better in heat
Power density 235.3 Wp/m² 207.1 Wp/m² 28.2 Wp/m² higher
Annual degradation 0.40 %/yr 0.55 %/yr 0.15 %/yr slower
Open-circuit voltage 48.93 V 43.47 V 5.46 V apart
Short-circuit current 16.01 A 18.75 A 2.74 A apart
Module area 2.699 m² 3.114 m² 0.415 m² apart
Cell technology TOPCon PERC TOPCon vs PERC
Rated power 635 Wp 645 Wp 10 W more power
Voltage at max power 41.88 V 37.15 V 4.73 V apart
Current at max power 15.18 A 17.37 A 2.19 A apart
Dimensions 2382x1133x30 mm 2390x1303x35 mm 2382x1133x30 mm vs 2390x1303x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AB-G12R-132-635
21,306 kWh
ASB-M12-132-645
20,904 kWh
Lifetime gap
402 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AB-G12R-132-635 ASB-M12-132-645
Standard test conditions 25 °C 100.0% of rated power 635 W 645 W
Cool, bright day 40 °C 94.8% of rated power 608 W 611 W
Typical summer roof 55 °C 89.5% of rated power 582 W 577 W
Hot roof 70 °C 84.2% of rated power 555 W 543 W
03

Full specification

Parameter AB-G12R-132-635 ASB-M12-132-645 Difference
Power and efficiency
Rated power 635 Wp 645 Wp +10 W for ASB-M12-132-645
Module efficiency 23.53 % 20.71 % +2.82 pp for AB-G12R-132-635
Power density 235.3 Wp/m² 207.1 Wp/m² +28.2 Wp/m² for AB-G12R-132-635
Open-circuit voltage 48.93 V 43.47 V 5.46 V apart
Voltage at max power 41.88 V 37.15 V 4.73 V apart
Short-circuit current 16.01 A 18.75 A 2.74 A apart
Current at max power 15.18 A 17.37 A 2.19 A apart
Temperature
Temperature coefficient -0.280 %/°C -0.350 %/°C +0.070 %/°C for AB-G12R-132-635
Mechanical
Dimensions 2382x1133x30 mm 2390x1303x35 mm 2382x1133x30 mm vs 2390x1303x35 mm
Module area 2.699 m² 3.114 m² 0.415 m² apart
Weight 33.6 kg 33.6 kg Same
Weight per kWp 52.9 kg/kWp 52.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.55 %/yr -0.15 %/yr for AB-G12R-132-635
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#766 vs #10,968
AB-G12R-132-635 leads by 10,202 places
Power density
#763 vs #11,003
AB-G12R-132-635 leads by 10,240 places
Heat behaviour
#1,409 vs #10,660
AB-G12R-132-635 leads by 9,251 places
Weight
#6,771 vs #5,650
ASB-M12-132-645 leads by 1,121 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#1,793 vs #4,362
AB-G12R-132-635 leads by 2,569 places
05

More useful comparisons

Open the full database
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-640
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-630
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-625
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-620
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-615
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-635 vs Adani Solar AB-G12R-132-610
4 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Adani Solar AB-G12R-132-635 or Adani Solar ASB-M12-132-645?
According to our database: Adani Solar AB-G12R-132-635 has higher module efficiency (23.53% vs 20.71%); Adani Solar AB-G12R-132-635 tolerates heat better (temp coeff -0.280%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Adani Solar AB-G12R-132-635 and Adani Solar ASB-M12-132-645?
Adani Solar AB-G12R-132-635 has a module efficiency of 23.53%, while Adani Solar ASB-M12-132-645 is 20.71%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Adani Solar AB-G12R-132-635 use vs Adani Solar ASB-M12-132-645?
Adani Solar AB-G12R-132-635 uses TOPCon cells; Adani Solar ASB-M12-132-645 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Adani Solar AB-G12R-132-635 and Adani Solar ASB-M12-132-645?
Adani Solar AB-G12R-132-635 has a 30 years power warranty; Adani Solar ASB-M12-132-645 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Adani Solar AB-G12R-132-635 and Adani Solar ASB-M12-132-645 bifacial panels?
Both Adani Solar AB-G12R-132-635 and Adani Solar ASB-M12-132-645 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.