Skip to main content
AB-G12R-132-630 vs BiN-08-570 5 of 19 identical Swap Change panels

Adani Solar AB-G12R-132-630 vs Waaree BiN-08-570

Adani Solar
AB-G12R-132-630
630 Wp 23.34 % TOPCon Bifacial
VS
BiN-08-570
570 Wp 22.07 % N-type Bifacial
The verdict

AB-G12R-132-630 leads on the differences that matter

The largest is module efficiency: 1.27 pp more efficient. 5 of 19 comparable parameters are identical.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs
01

What actually differs

14 of 19 parameters
Parameter AB-G12R-132-630 BiN-08-570 Difference
Module efficiency 23.34 % 22.07 % 1.27 pp more efficient
Rated power 630 Wp 570 Wp 60 W more power
Power density 233.4 Wp/m² 220.7 Wp/m² 12.8 Wp/m² higher
Temperature coefficient -0.280 %/°C -0.300 %/°C 0.020 %/°C better in heat
Short-circuit current 15.94 A 13.81 A 2.13 A apart
Module area 2.699 m² 2.583 m² 0.116 m² apart
Open-circuit voltage 48.80 V 52.10 V 3.30 V apart
Weight per kWp 53.3 kg/kWp 57.0 kg/kWp 3.7 kg/kWp lighter
Cell technology TOPCon N-type TOPCon vs N-type
Current at max power 15.11 A 13.04 A 2.07 A apart
Cell count 132 144 12 cells apart
Weight 33.6 kg 32.5 kg 1.1 kg lighter
Dimensions 2382x1133x30 mm 2278x1134x33 mm 2382x1133x30 mm vs 2278x1134x33 mm
Voltage at max power 41.72 V 43.71 V 1.99 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AB-G12R-132-630
21,138 kWh
BiN-08-570
19,125 kWh
Lifetime gap
2,013 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AB-G12R-132-630 BiN-08-570
Standard test conditions 25 °C 100.0% of rated power 630 W 570 W
Cool, bright day 40 °C 95.5% of rated power 604 W 544 W
Typical summer roof 55 °C 91.0% of rated power 577 W 519 W
Hot roof 70 °C 86.5% of rated power 551 W 493 W
03

Full specification

Parameter AB-G12R-132-630 BiN-08-570 Difference
Power and efficiency
Rated power 630 Wp 570 Wp +60 W for AB-G12R-132-630
Module efficiency 23.34 % 22.07 % +1.27 pp for AB-G12R-132-630
Power density 233.4 Wp/m² 220.7 Wp/m² +12.8 Wp/m² for AB-G12R-132-630
Open-circuit voltage 48.80 V 52.10 V 3.30 V apart
Voltage at max power 41.72 V 43.71 V 1.99 V apart
Short-circuit current 15.94 A 13.81 A 2.13 A apart
Current at max power 15.11 A 13.04 A 2.07 A apart
Temperature
Temperature coefficient -0.280 %/°C -0.300 %/°C +0.020 %/°C for AB-G12R-132-630
Mechanical
Dimensions 2382x1133x30 mm 2278x1134x33 mm 2382x1133x30 mm vs 2278x1134x33 mm
Module area 2.699 m² 2.583 m² 0.116 m² apart
Weight 33.6 kg 32.5 kg -1.1 kg for BiN-08-570
Weight per kWp 53.3 kg/kWp 57.0 kg/kWp -3.7 kg/kWp for AB-G12R-132-630
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon N-type TOPCon vs N-type
Cell type Monocrystalline Monocrystalline Same
Cell count 132 144 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,129 panels
Efficiency
#981 vs #6,199
AB-G12R-132-630 leads by 5,218 places
Power density
#971 vs #6,121
AB-G12R-132-630 leads by 5,150 places
Heat behaviour
#1,347 vs #6,152
AB-G12R-132-630 leads by 4,805 places
Weight
#7,304 vs #11,095
AB-G12R-132-630 leads by 3,791 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,986 vs #5,396
AB-G12R-132-630 leads by 3,410 places
05

More useful comparisons

Open the full database
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-640
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-635
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-625
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-620
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-615
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-610
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Adani Solar AB-G12R-132-630 or Waaree BiN-08-570?
According to our database: Adani Solar AB-G12R-132-630 has higher module efficiency (23.34% vs 22.07%); Adani Solar AB-G12R-132-630 tolerates heat better (temp coeff -0.280%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Adani Solar AB-G12R-132-630 and Waaree BiN-08-570?
Adani Solar AB-G12R-132-630 has a module efficiency of 23.34%, while Waaree BiN-08-570 is 22.07%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Adani Solar AB-G12R-132-630 use vs Waaree BiN-08-570?
Adani Solar AB-G12R-132-630 uses TOPCon cells; Waaree BiN-08-570 uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Adani Solar AB-G12R-132-630 and Waaree BiN-08-570?
Adani Solar AB-G12R-132-630 has a 30 years power warranty; Waaree BiN-08-570 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Adani Solar AB-G12R-132-630 and Waaree BiN-08-570 bifacial panels?
Both Adani Solar AB-G12R-132-630 and Waaree BiN-08-570 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Compare Adani Solar and Waaree as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 24 Waaree offers