Skip to main content
AB-G12R-132-630 vs ASB-M10-144-530 7 of 19 identical Swap Change panels

Adani Solar AB-G12R-132-630 vs Adani Solar ASB-M10-144-530

Adani Solar
AB-G12R-132-630
630 Wp 23.34 % TOPCon Bifacial
VS
Adani Solar
ASB-M10-144-530
530 Wp 20.64 % PERC Bifacial
The verdict

AB-G12R-132-630 leads on the differences that matter

The largest is module efficiency: 2.70 pp more efficient. 7 of 19 comparable parameters are identical.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs
01

What actually differs

12 of 19 parameters
Parameter AB-G12R-132-630 ASB-M10-144-530 Difference
Module efficiency 23.34 % 20.64 % 2.70 pp more efficient
Temperature coefficient -0.280 %/°C -0.340 %/°C 0.060 %/°C better in heat
Rated power 630 Wp 530 Wp 100 W more power
Power density 233.4 Wp/m² 206.4 Wp/m² 27.0 Wp/m² higher
Weight 33.6 kg 28.0 kg 5.6 kg lighter
Short-circuit current 15.94 A 13.55 A 2.39 A apart
Module area 2.699 m² 2.567 m² 0.131 m² apart
Cell technology TOPCon PERC TOPCon vs PERC
Current at max power 15.11 A 12.79 A 2.32 A apart
Cell count 132 144 12 cells apart
Annual degradation 0.40 %/yr 0.45 %/yr 0.05 %/yr slower
Dimensions 2382x1133x30 mm 2266x1133x35 mm 2382x1133x30 mm vs 2266x1133x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AB-G12R-132-630
21,138 kWh
ASB-M10-144-530
17,453 kWh
Lifetime gap
3,685 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AB-G12R-132-630 ASB-M10-144-530
Standard test conditions 25 °C 100.0% of rated power 630 W 530 W
Cool, bright day 40 °C 94.9% of rated power 604 W 503 W
Typical summer roof 55 °C 89.8% of rated power 577 W 476 W
Hot roof 70 °C 84.7% of rated power 551 W 449 W
03

Full specification

Parameter AB-G12R-132-630 ASB-M10-144-530 Difference
Power and efficiency
Rated power 630 Wp 530 Wp +100 W for AB-G12R-132-630
Module efficiency 23.34 % 20.64 % +2.70 pp for AB-G12R-132-630
Power density 233.4 Wp/m² 206.4 Wp/m² +27.0 Wp/m² for AB-G12R-132-630
Open-circuit voltage 48.80 V 48.95 V Effectively the same
Voltage at max power 41.72 V 41.49 V Effectively the same
Short-circuit current 15.94 A 13.55 A 2.39 A apart
Current at max power 15.11 A 12.79 A 2.32 A apart
Temperature
Temperature coefficient -0.280 %/°C -0.340 %/°C +0.060 %/°C for AB-G12R-132-630
Mechanical
Dimensions 2382x1133x30 mm 2266x1133x35 mm 2382x1133x30 mm vs 2266x1133x35 mm
Module area 2.699 m² 2.567 m² 0.131 m² apart
Weight 33.6 kg 28.0 kg -5.6 kg for ASB-M10-144-530
Weight per kWp 53.3 kg/kWp 52.8 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.45 %/yr -0.05 %/yr for AB-G12R-132-630
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 132 144 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#943 vs #11,037
AB-G12R-132-630 leads by 10,094 places
Power density
#933 vs #11,017
AB-G12R-132-630 leads by 10,084 places
Heat behaviour
#1,309 vs #8,778
AB-G12R-132-630 leads by 7,469 places
Weight
#7,236 vs #6,527
ASB-M10-144-530 leads by 709 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,961 vs #8,573
AB-G12R-132-630 leads by 6,612 places
05

More useful comparisons

Open the full database
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-640
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-635
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-625
The same specification on paper
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-620
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-615
3 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar AB-G12R-132-630 vs Adani Solar AB-G12R-132-610
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Adani Solar AB-G12R-132-630 or Adani Solar ASB-M10-144-530?
According to our database: Adani Solar AB-G12R-132-630 has higher module efficiency (23.34% vs 20.64%); Adani Solar AB-G12R-132-630 tolerates heat better (temp coeff -0.280%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Adani Solar AB-G12R-132-630 and Adani Solar ASB-M10-144-530?
Adani Solar AB-G12R-132-630 has a module efficiency of 23.34%, while Adani Solar ASB-M10-144-530 is 20.64%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Adani Solar AB-G12R-132-630 use vs Adani Solar ASB-M10-144-530?
Adani Solar AB-G12R-132-630 uses TOPCon cells; Adani Solar ASB-M10-144-530 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Adani Solar AB-G12R-132-630 and Adani Solar ASB-M10-144-530?
Adani Solar AB-G12R-132-630 has a 30 years power warranty; Adani Solar ASB-M10-144-530 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Adani Solar AB-G12R-132-630 and Adani Solar ASB-M10-144-530 bifacial panels?
Both Adani Solar AB-G12R-132-630 and Adani Solar ASB-M10-144-530 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Adani Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.