Sungrow SG40CX vs Sungrow SG40CX-P2
VS
The verdict
SG40CX-P2 leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 13 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
13
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 19 parameters
What actually differs
Parameter
SG40CX
SG40CX-P2
Difference
Max input current per tracker
26.0 A
30.0 A
4.0 A more headroom
Weight
58.0 kg
40.0 kg
18.0 kg lighter
Weight per kW
1.4 kg/kW
1.0 kg/kW
0.4 kg/kW lighter
Start voltage
250 V
200 V
50 V earlier start
MPPT voltage range
200-1000 V
160-1000 V
200-1000 V vs 160-1000 V
Dimensions
645x782x310 mm
575x645x245 mm
645x782x310 mm vs 575x645x245 mm
02
Full specification
Parameter
SG40CX
SG40CX-P2
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
66.9 A
66.9 A
Same
PV input
Max PV power
-
56.00 kW
Not published by Sungrow
DC/AC ratio
-
1.40
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
160-1000 V
200-1000 V vs 160-1000 V
Start voltage
250 V
200 V
-50 V for SG40CX-P2
MPP trackers
-
4
Not published by Sungrow
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
30.0 A
+4.0 A for SG40CX-P2
Efficiency
European efficiency
98.3 %
98.3 %
Same
Max efficiency
98.6 %
98.5 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
58.0 kg
40.0 kg
-18.0 kg for SG40CX-P2
Weight per kW
1.4 kg/kW
1.0 kg/kW
-0.4 kg/kW for SG40CX-P2
Dimensions
645x782x310 mm
575x645x245 mm
645x782x310 mm vs 575x645x245 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG40CX vs Growatt MID 40KTL3-X
5 differences, the largest is weight
Same type, similar size
Huawei
Sungrow SG40CX vs Huawei SUN2000-40KTL-M3
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Sungrow SG40CX vs Solis-40K
5 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

