Sungrow SG40CX vs Huawei SUN2000-40KTL-M3
VS
The verdict
SUN2000-40KTL-M3 leads on the differences that matter
The largest is max ac power: 4.00 kW apart. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 19 parameters
What actually differs
Parameter
SG40CX
SUN2000-40KTL-M3
Difference
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Weight
58.0 kg
43.0 kg
15.0 kg lighter
Max AC current
66.9 A
63.8 A
3.1 A apart
Start voltage
250 V
200 V
50 V earlier start
Weight per kW
1.4 kg/kW
1.1 kg/kW
0.4 kg/kW lighter
Dimensions
645x782x310 mm
530x640x270 mm
645x782x310 mm vs 530x640x270 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SG40CX
SUN2000-40KTL-M3
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
66.9 A
63.8 A
3.1 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
250 V
200 V
-50 V for SUN2000-40KTL-M3
MPP trackers
-
4
Not published by Sungrow
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
26.0 A
Same
Efficiency
European efficiency
98.3 %
98.4 %
Effectively the same
Max efficiency
98.6 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
58.0 kg
43.0 kg
-15.0 kg for SUN2000-40KTL-M3
Weight per kW
1.4 kg/kW
1.1 kg/kW
-0.4 kg/kW for SUN2000-40KTL-M3
Dimensions
645x782x310 mm
530x640x270 mm
645x782x310 mm vs 530x640x270 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG40CX vs Growatt MID 40KTL3-X
5 differences, the largest is weight
Same type, similar size
Ginlong Solis
Sungrow SG40CX vs Solis-40K
5 differences, the largest is weight
Same type, similar size
Sungrow
Sungrow SG40CX vs Sungrow SG40CX-P2
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.